Connect the output of the driver to the first light bar using the 30” 

interconnection cable. The output of first light bar (6” cable) must be connected to 

the 30” cable of the 2nd lightbar, and so on. 
•  For ML900, only 2 lightbars should be connected as shown. 

•  For ML300, a minimum of 4, and a maximum of 6 light bars can be connected. 

Connecting less than 4 ML300 light bars may damage the product. 

•  Connect the shorting cap to the last 6” lightbar cable, as shown, or else the array will 

not light. The shorting cap must be secured such that it does not touch the light bar.

Shorting Cap Installation

ML900 Electrical Connection: 2 Lightbars only

ML 300 Electrical connection: 4, 5, or 6 Lightbars only

For all configurations greater than 5 bars, only use  3ft or 6ft extension cable (GECA30A14-AA03B  or 

GECA30A14-AA06B interconnection cables) in conjunction with LED Drivers without NEMA plugs 

(GEPSC210-600D-ADGNA-D1XA1  and  GEPSC210-600G-AGJNA-D1XA1).

600W

Driver

Lightbar 1

Interconnection cable

Lightbar 2

600W

Driver

Lightbar 1

Lightbar 3

Lightbar 2

Lightbar 4

Lightbar 5

Lightbar 6

ML300

ML900

RISK OF SAFETY AND PRODUCT DAMAGE. DO NOT MAKE OR BREAK 

ELECTRICAL CONNECTION WHILE POWER IS APPLIED.

Shorting Cap

9

1

1

1

1

1

1

1

1

2

2

Shorting Cap

9

Shorting Cap

9

3

Содержание Arize 95051589

Страница 1: ... luminaire ensure that the lightbar and driver are clean and free of dirt dust oil or any other debris Do not apply any kind of film on the lens or otherwise cover the driver or light engine in any way RISQUE DE CHOC ELECTRIQUE Suivez la procédure de sécurité appropriée de verrouillage étiquetage Reliez correctement le boîtier électrique à la mise à la terre Suivre tous les codes électriques locau...

Страница 2: ...277 347VAC 2 5 2A GEPSC210 600G AGJNA D17A1 NEMA L7 15P 3 48 kg 7 33lbs 277 VAC 2 5A Product Code Detailed Description Weight Series Load per Driver System Watts per Lightbar GEHF HPKRW1 ML900 PKR 2 6 kg 5 7lbs 2 319W GEHF HPKBW1 ML900 PKB 2 6 kg 5 7lbs 2 313W GEHF HPKFW1 ML900 PKF 2 6 kg 5 7lbs 2 313W GEHF HBRIW1 ML900 BRI 2 6 kg 5 7lbs 2 319W GEHF HBRVW1 ML900 BRV 2 6 kg 5 7lbs 2 316W GEHF MPKRW...

Страница 3: ...between Lightbars 15 Mounting Accessories SKU Description Detailed Description Weight 95051690 GEMB BANE Factor suspended mount wireform support 0 012 kg 0 026lbs 95051689 GEMB BAW1 Factor rolling rack mount 24 inch pitch 1 756 kg 3 86 lbs 95051688 GEMB BAW2 Factor rolling rack mount 48 inch pitch 3 69 kg 8 1 lbs 95051691 GEMB FANE Factor light engine mount 3 82 kg 8 4 lbs 95047411 GEHAK NN NE N0 ...

Страница 4: ...two screws located at each end of the bracket After the horizontal bracket is attached to the strut secure the bracket to the struts by tightening the two screws located each end of the bracket ML300 Rolling Rack Mount 24 DC Power Input Output Power Input Output Lightbar Lightbars Mounting Brackets Mounting Brackets Driver Driver Tighten screws both sides Tighten screws both sides 4 1 1 7 2 2 5 ...

Страница 5: ...L Series lightbar can suspended on a support structure A or on cables as shown above B and C Attach wireform supports by pushing up into the slots on the underside of the lightbar A Adjust screws to level the lightbar with screwdriver B After lightbar is leveled tighten the 2 screws at the bottom Slots Wireform supports Suspended Mount Installation Steps Cross section view 6 1 A A B B 2 A B C ...

Страница 6: ...the screws shown Components required GEHAK NN NE N0 Driver universal 1 remote mount kit 95047411 2 required Insert each toggle into the hole in the top of each driver bracket Wrap the two toggle cables around the support structure Thread the toggle through the loop in each toggle cable Hang the driver from the support structure ML300 LED Driver Mounting Option A Installation Support structure 8 1 ...

Страница 7: ...t be secured such that it does not touch the light bar Shorting Cap Installation ML900 Electrical Connection 2 Lightbars only ML 300 Electrical connection 4 5 or 6 Lightbars only For all configurations greater than 5 bars only use 3ft or 6ft extension cable GECA30A14 AA03B or GECA30A14 AA06B interconnection cables in conjunction with LED Drivers without NEMA plugs GEPSC210 600D ADGNA D1XA1 and GEP...

Страница 8: ...e key guides from Male to Female connector Driver Output and Lightbar Electrical Connections Connection Schematic 1 2 DO NOT MAKE OR BREAK ELECTRICAL CONNECTION WHILE POWER IS APPLIED Driver Input Wire Colors Black Line 1 White Neutral or Line 2 Yellow Green Ground Optional 3 or 6 interconnection cable NOTE Maximum cumulative length of interconnection cable is 6 feet WARNING AVERTISSEMENT RISK OF ...

Страница 9: ...placement Ensure gasket is sitting in place on the inner edge of the junction box cover Fasten all 6 screws to ensure water tight seal NOTE Be careful not to strip out the junction box enclosure by over tightening the screws Driver Dimming Switch Violet Blue Pink Black Gray 0 10V 0 10V Gasket in cover 1 3 2 4 Remove cover Dimming In To lightbar AC input Remove screws WARNING AVERTISSEMENT RISK OF ...

Страница 10: ...dress these risks at the facility level and to ensure that people entering the plant growth areas while the lights are on are aware of these risks and that appropriate safeguards are in place Ces avertissements de sécurité photobiologiques sont basés sur des tests du rendement lumineux d un seul luminaire horticole Les employés risquent de souffrir d une exposition accrue selon le nombre de lumina...

Отзывы: