GE Appliances GMAN1200 Скачать руководство пользователя страница 5

SERVICE MODE

To Enter:

 Press 

Temp-e Wash-Temp-e Wash

 (within 30 seconds of plugging 

in washer).

To Exit:

 Repeat press 

Temp-e Wash-Temp-e Wash

.

TEST LIST

“t01” 

Model ID

 

Verifies (or sets on new board) the proper Model id

“t02” 

Error Codes

 

Lists up to 10 control-detected problems

“t03” 

Software ID

 

Verifies using latest UL code - Control - eePROM - Inverter software

“t04” 

Exercise LCD/LEDs

 

Verifies that all the displays and buttons work

“t05” 

Pump Test

 

Test drain-out pump

“t06” 

Pressure Switch Test

 

Fills to all 3 levels, then pumps out water

“t07” 

Thermistor/Heater Test

 

Verifies that both the Thermistor and Heater work

“t08” 

Steam Test

 

Verifies that Steam generator work

“t10” 

Tumble Test

 

Verifies Washer Tumbles (i.e. Wash cycle)

“t11” 

Spin Test

 

Verifies Washer spins

“t12” 

Dispenser Test

 

Verifies Dispenser fill works—for all four fill modes

“t13” 

EOL Test

 

Performs End-of-Line test sequence

5

FOR SERVICE TECHNICIAN ONLY—DO NOT REMOVE OR DESTROY

CONTROL BOARD CONNECTOR LOCATIONS

175D6149P002

Содержание Appliances GMAN1200

Страница 1: ...sed into connections far enough The most common cause for control failure is corrosion on connectors Therefore disconnecting and reconnecting wires will be necessary throughout test procedures Connect...

Страница 2: ...2 FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY 175D6149P002 WIRE DRAWING for models GFWN1100 GFWN 1200 GFWN1300 and GMAN1200 WIRE DRAWING for models GFWH1400 and GFWH1405...

Страница 3: ...3 FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY 175D6149P002 WIRE DRAWING for models GFWH1200 and GFWH1300 WIRE DRAWING for models GFWS1500 and GFWS1505...

Страница 4: ...4 FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY 175D6149P002 SYSTEM DRAWING...

Страница 5: ...at all the displays and buttons work t05 Pump Test Test drain out pump t06 Pressure Switch Test Fills to all 3 levels then pumps out water t07 Thermistor Heater Test Verifies that both the Thermistor...

Страница 6: ...um of 5 minutes Power Pumps out water and returns to t07 t08 none Start Displays SEA and rotates the basket at 43 revolutions per minute only for GFWS1500 and GFWS1505 models Power Stops rotating the...

Страница 7: ...sure AC outlet voltage ensure correct range 102V to 132V AC 4B 4C internal Check electrical connections at the drum motor motor drive 50 52 problems Check harness integrity between main control and mo...

Страница 8: ...OR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY MODEL NUMBERS GFWN1100 GFWN1200 GFWH1200 GMAN1200 GFWN1300 GFWH1300 GFWH1400 GFWH1405 GFWS1500 GFWS1505 31 16849 04 12 GE Printed in China 175D6149P...

Отзывы: