background image

“L” WASHER

IMPORTANT

Electric Discharge (ESD)

Sensitive Electronics

ESD problems are present everywhere. ESD may damage or weaken the 

electronic control assembly. The new control assembly may appear to work 

well after repair is finished, but failure may occur at a later date due to ESD 

stress.

• Use an anti-static wrist strap. Connect wrist strap to ground connection 

point or unpainted metal in the appliance.

  –OR–
  Touch your finger repeatedly to ground connection point or unpainted 

metal in the appliance.

• Before removing the part from its package, touch the anti-static bag to a 

green ground connection point or unpainted metal in the appliance.

• Avoid touching electronic parts or terminal contact; handle electronic 

control assembly by edges only.

• When repackaging failed electronic control assembly in anti-static bag, 

observe above-mentioned precautions.

DIAGNOSTIC GUIDE

Before testing washer operation, check the following:

• Is the power cord firmly plugged into a live circuit?
• Has a household fuse blown or circuit breaker tripped? Time delay fuse?
• Are both hot and cold water faucets open and water supply hoses 

unobstructed?

  Before opening the unit make sure the washer is unplugged from power 

outlet.

• Check all connections before replacing components. Look for broken or 

loose wires, failed terminals, or wires not pressed into connections far 

enough.

• The most common cause for control failure is corrosion on connectors. 

Therefore, disconnecting and reconnecting wires will be necessary 

throughout test procedures.

• Connectors: Look at top of connector. Check for broken or loose wires. 

Check for wires not pressed into connector far enough to engage metal 

barbs.

• Resistance check must be made with power cord unplugged from outlet, 

and with wiring harness or connectors disconnected.

FOR SERVICE TECHNICIAN ONLY—DO NOT REMOVE OR DESTROY

175D6149P002

WARNING

Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in injury or death.

Electrical Shock Hazard

Programming the Control Board

• The replacement control board will always enter into test mode t01 on 

initial power-up.

• If replacing the control board, the washer will not function until the 

replacement control board has been programmed.

To program the replacement control board:

1.

  Reconnect power to the washer. (The display will now show “---”, which 

means no model has been selected.)

2.

  Rotate the cycle knob until the correct model number is displayed:

Display “1” = GFWN1100, GFWN1200, GMAN1200
Display “2” = GFWH1200
Display “3” = GFWN1300
Display “4” = GFWH1300
Display “5” = GFWH1400, GFWH1405
Display “6” = GFWS1500, GFWS1505

3. 

  Press and hold the Start key for 3 seconds (or until a second beep is 

sounded).

4.

  Press the Power key to reset the control.

Note:

 If an error is made in programming the control, enter test mode and 

select t01. Then repeat steps 2 through 4.

Содержание Appliances GMAN1200

Страница 1: ...sed into connections far enough The most common cause for control failure is corrosion on connectors Therefore disconnecting and reconnecting wires will be necessary throughout test procedures Connect...

Страница 2: ...2 FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY 175D6149P002 WIRE DRAWING for models GFWN1100 GFWN 1200 GFWN1300 and GMAN1200 WIRE DRAWING for models GFWH1400 and GFWH1405...

Страница 3: ...3 FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY 175D6149P002 WIRE DRAWING for models GFWH1200 and GFWH1300 WIRE DRAWING for models GFWS1500 and GFWS1505...

Страница 4: ...4 FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY 175D6149P002 SYSTEM DRAWING...

Страница 5: ...at all the displays and buttons work t05 Pump Test Test drain out pump t06 Pressure Switch Test Fills to all 3 levels then pumps out water t07 Thermistor Heater Test Verifies that both the Thermistor...

Страница 6: ...um of 5 minutes Power Pumps out water and returns to t07 t08 none Start Displays SEA and rotates the basket at 43 revolutions per minute only for GFWS1500 and GFWS1505 models Power Stops rotating the...

Страница 7: ...sure AC outlet voltage ensure correct range 102V to 132V AC 4B 4C internal Check electrical connections at the drum motor motor drive 50 52 problems Check harness integrity between main control and mo...

Страница 8: ...OR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY MODEL NUMBERS GFWN1100 GFWN1200 GFWH1200 GMAN1200 GFWN1300 GFWH1300 GFWH1400 GFWH1405 GFWS1500 GFWS1505 31 16849 04 12 GE Printed in China 175D6149P...