Ordering Information
Maintaining the Detector
When installed and used properly, the AP950PI provides many years
of service with minimal maintenance. To ensure proper operation,
you should walk test the unit annually.
Clean the inside of the unit with a soft bristled brush or compressed
air. Clean the outside with a damp (water) cloth as needed to keep it
free of dust and dirt. Always test the unit after cleaning.
Model Number
Description
AP950PI
PIR, closed loop, Form A, 35 foot (10.7m) pet immune mirror installed, 50 foot (15.2m) standard mirror
included
Specifications
Input voltage ............................................................. 8.2 to 15VDC
Input voltage (UL) ............................................... 9.7 to 13.6 VDC
Peak to peak ripple ........................................... 2V max at 12VDC
Current consumption ..................................................... 17mA max
Mounting height ............................................ 7' to 10' (2.1m to 3m)
Relay contacts .................................................... 50 mA max at 28V
Relay type .................................................. Closed loop (Form A)
Alarm time (LED and relay) ............................... 2.9 to 3.5 seconds
Operating temperature ....................... 0° to 122° F (-18° to 50° C)
Relative humidity .......................................... 93% non-condensing
RFI immunity ........................ - 20V/meter from 28 to 1000MHz
Weight .................................................................... 0.26 lbs (120 g)
Dimensions:
Width .................................................................... 2.9" (7.4 cm)
Depth .................................................................. .2.1" (5.2 cm)
Height ................................................................ 4.7" (12.0 cm)
Number of curtains ....................................................................... 9
View angle ................................................................................. 89°
Detection range ............................ 50' (15.2m) with standard mirror
and sensitivity set to Increased
35' (10.7m) with pet immune mirror
and sensitivity set to Standard
Listings ............................................................................. C-UL US
>
1037263 Rev B 06/02
Dimensions
4.7"
12.0cm
2.9"
7.4cm
2.1"
5.2cm
12345 SW Leveton Drive
Tualatin, OR 97062
www.interlogixsecurity.com
www.sentrol.com
© 2002 GE Interlogix, Inc.
Phone: 503-692-4052
USA & Canada: 800-547-2556
Technical Service: 800-648-7424
FaxBack: 800-483-2495
GE Interlogix
Operation Information
When the unit is powered up, the LED turns on and the relay
contacts open for about 12 seconds, then the LED goes off and the
relay contacts close. Thereafter, the LED will turn on and the relay
contacts will open every time an alarm occurs. The unit should be
allowed to settle for at least one minute after power-up before walk
testing. When walk testing, walk across the curtains, not directly
toward or away from the unit. Wait 10 seconds between trips to
allow the unit to stabilize.