Typical Installation

Recommended

heat trap 

6

minimum

Hot water outlet

to fixtures

6

air gap

Suitable open drain

6

Union

Temperature &

pressure relief

valve

Cold water supply

To cold water

supply

Shut-off valve

Relief 
valve
discharge
line to
suitable
open 
drain

Unions

*The drain valve is located below and to the right of jacket access panel and is

not visible in this view.

Anode

Jacket
access
panel

Water
Heater
Jacket 

Water
Heater
Jacket 

Power supply
cord 2

1

/

2

gal.

models only

Temperature &
pressure relief
valve

Opening
for 1/2

or 3/4

electrical
fitting 

(use only copper
conductors)

Auxiliary catch pan

Relief
valve
discharge
line 

Shut-off valve

Drain valve*

Jacket access
panel

Hot water
outlet 
(to fixtures)

Auxiliary
catch pan

Auxiliary catch
pan drain line

Auxiliary catch pan
drain line

Suitable open drain

7

WARNING: The pressure

rating of the relief valve
must not exceed 150 PSI,
the maximum working
pressure of the water
heater as marked on 
the rating plate. 

Relief Valve

The Btuh rating of the relief valve must
not be less than the input rating of the
water heater as indicated on the rating
label located on the front of the heater
(1 watt=3.412 Btuh).

Connect the outlet of the relief valve to a
suitable open drain so that the discharge
water cannot contact live electrical parts
or persons and to eliminate potential
water damage. 

Piping used should be of a type approved
for hot water distribution. The discharge
line must be no smaller than the outlet
of the valve and must pitch downward
from the valve to allow complete drainage
(by gravity) of the relief valve and discharge
line. The end of the discharge line should
not be threaded or concealed and should
be protected from freezing. No valve of
any type, restriction or reducer coupling
should be installed in the discharge line.

A new combination temperature and pressure relief valve, complying with the Standard for Relief Valves
and Automatic Gas Shut-Off Devices for Hot Water Supply Systems, ANSI Z21.22, is supplied and must
remain installed in the opening provided and marked for the purpose on the water heater. No valve of any
type should be installed between the relief valve and the tank. Local codes shall govern the installation of
relief valves.

Safety Instructions

Installation Instructions

Operating Instructions

Care and Cleaning

T

roubleshooting Tips

Customer Service

Drain valve

(not supplied)

Vacuum Relief Valve

(Not Supplied)

If required, install per local codes

and valve manufacturer’s

instructions.

Содержание AP12169-5

Страница 1: ...any 2600 Gunter Park Drive East Montgomery AL 36124 4020 Printed in USA Use Care Manual With Installation Instructions for the Installer IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical app...

Страница 2: ...abel on the appliance Staple sales slip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty IMPORTANT Fill out and return the Consumer Product Re...

Страница 3: ...the Operating Instructions in this manual for detailed instructions in how to adjust the thermostat s DANGER Hotter water increases the potential for Hot Water SCALDS D A N G E R HOT Water temperature...

Страница 4: ...rom Office of the State Architect 400 P Street Sacramento CA 95814 or you may call 916 445 8100 or ask a water heater dealer However applicable local codes shall govern installation For residential wa...

Страница 5: ...eatest heated water demand Long uninsulated hot water lines can waste energy and water Place the water heater in such a manner that the thermostat and element access panels can be removed to permit in...

Страница 6: ...d water line between the water heater and the check valve The expansion tank is designed with an air cushion built in that compresses as the system pressure increases thereby relieving the over pressu...

Страница 7: ...r 1 watt 3 412 Btuh Connect the outlet of the relief valve to a suitable open drain so that the discharge water cannot contact live electrical parts or persons and to eliminate potential water damage...

Страница 8: ...ket inside jacket at front of water heater An opening for 1 2 or 3 4 electrical fitting is provided for field wiring connections A separate branch circuit with copper conductors overcurrent protective...

Страница 9: ...devices CAUTION If local codes require the application of an external insulation blanket to this water heater pay careful attention to the following so as not to restrict the proper function and oper...

Страница 10: ...amage the dip tube and or heat traps Customer Service Troubleshooting Tips Care and Cleaning Operating Instructions Installation Instructions Safety Instructions R E L I E F V A L V E COLD HOT Typical...

Страница 11: ...Provisions made to protect area from water damage Sufficient room to service heater Water Supply Water heater completely filled with water Air purged from water heater and piping Water connections tig...

Страница 12: ...h as air escaping through the pipe as the water begins to flow Do not smoke or use an open flame near the faucet at the time it is open CAUTION The cause of the high temperature condition must be inve...

Страница 13: ...ergy conservation are factors to be considered when selecting the water temperature setting of the water heater s thermostat s The lower the temperature setting the greater the savings in energy and o...

Страница 14: ...tank and will exclude warranty coverage Care and cleaning of the water heater Draining the Water Heater CAUTION Shut off power to the water heater before draining water DANGER Before manually operati...

Страница 15: ...nect switch if used are in the ON position The thermostat may See the Temperature regulation of the water heater be set set too low section of this manual Leaking or open hot Make sure all faucets are...

Страница 16: ...s heating elements or other operating controls Refer repairs to qualified service personnel 21 2 Gallon Models R E S E T R E S E T 1 4 0 1 3 0 1 2 0 1 1 0 1 0 0 9 0 T H E R M O D I S C T U R N O F F...

Страница 17: ...CO HEATING ELEMENT WHITE BLACK BLACK H BRANCH CIRCUIT TO ELECTRICAL DISTRIBUTION PANEL JUNCTION BOX N 1 G 17 Wiring diagrams Wiring Diagrams for Type 59T Therm o disc Thermostats 120 V Plug Connected...

Страница 18: ...18 Notes Customer Service Troubleshooting Tips Care and Cleaning Operating Instructions Installation Instructions Safety Instructions...

Страница 19: ...19 Rheem Manufacturing Company Warranty Registration Department P O Box 34070 Louisville KY 40232 4070 Please place in envelope and mail to Cut here Cut here...

Страница 20: ...Mr Ms Mrs Miss Street Address City State Date Placed In Use Month Day Year Zip Code Apt Last Name Phone Number _ _ Complete and mail this Consumer Product Ownership Registration today After mailing th...

Отзывы: