GE Allegro 60-874-95R Скачать руководство пользователя страница 11

Programming the Panel

5

2. Slide the battery pack into the space provided on the back of the panel (Figure 5). 

Note  

Be sure to run the battery 
pack wires below the battery 
and through the wire chan-
nel.

3. Plug the battery pack lead into the slot provided next to the wire terminals 

(Figure 5). 

4. Replace the panel housing on the back mounting plate and snap into place.

Note  

Verify the front door is in place before replacing the panel on the mounting plate. It is not possible to 
attach the door after the panel is secured to the mounting plate.

Powering Up the Panel

After connecting and wiring all devices to the panel, you are ready to apply AC power to the 
panel.

Note  

See “Appendix A: Trouble-
shooting” on page 28 if the 
panel displays 

LOW

 

BATTERY

.

¾

To power up the panel:

Plug the transformer into an outlet that is not controlled by a switch or ground fault circuit 
interrupt (GFCI). Be sure to screw the top of the transformer onto the outlet so that it doesn’t 
fall out of the outlet. 

If the DTIM is learned into the system (see “Learning the DTIM into the Panel” on page 6) 
the panel displays 

TEL

 

MODULE

 

INITIALIZING

 

while the panel and the DTIM sync up. This will 

take approximately 5 minutes. 

To eliminate the 5 minute wait, remove and replace the DTIM cover after powering up the 
Allegro system.

Programming 
the Panel

This section describes how to navigate through the programming menus, clear memory, and learn 
the DTIM into the panel. You can program the panel manually using the panel keypad on site. 
Alternately, ToolBox

®

 downloader software version 5.7 or later allows you to program remotely 

via a modem and phone line. See “Downloader Programming” on page 25.

Panel Keypad Button Programming Functions

In program mode, panel keypad buttons let you navigate to all installer programming menus for 
configuring the system. Table 1 describes the panel keypad button functions in program mode.

Be careful when securing the transformer to an outlet with a metal cover. Hold the 
cover tightly in place. You could receive a serious shock if the metal outlet cover drops 
onto the prongs of the plug while you are securing the transformer and cover to the 
outlet box.
If the panel does not display anything, immediately unplug the transformer and discon-
nect the backup battery. Refer to the “Troubleshooting” section.

Warning

!

Table 1: Button Functions

Button

Programming Function

Selects menu item or data entry (move to tier 2 program-
ming). Toggles between on and off whenever needed.

Deselects menu item or data entry (if pressed before 

#

). 

Returns to the tier 1 program menu.

Scroll through available options at the current menu tier. 
Press 

 

to advance forward through the menus. Press 

 to 

backup through the menus.

Deletes options that can be deleted. 

0 - 9

Enter numeric values wherever needed.

1 - 6

Press and hold to enter A-F in account numbers.

Silent

Press to enter a pause in phone numbers. Pause displays as 
a “P”.

7

Press and hold to enter “*” characters in phone numbers.

9

Press and hold to enter “#” characters in phone numbers.

B y p a s s

S e l e c t

#

B a c k

*

S t a t u s

(twice)

B y p a s s

#

Содержание Allegro 60-874-95R

Страница 1: ...QWHUORJL Installation Instructions 466 1821 Rev C June 2003 Allegro Part No 60 874 95R ZZZ QWHUORJL FRP...

Страница 2: ...eiving antenna Increase the separation between the equipment and receiver Connect the affected equipment and the panel receiver to separate outlets on different branch circuits Consult the dealer or a...

Страница 3: ...nting the Panel 3 Connecting Detection Devices to Panel Zone Inputs 4 Connecting Intrusion Detection Devices 4 Connecting the AC Power Transformer 4 Connecting the Backup Battery Pack 4 Powering Up th...

Страница 4: ...15 REARM TIMER 2nd Tier 15 Options 1st Tier 16 KTP ARM 2nd Tier 16 POLICE PANIC 2nd Tier 16 EMERGENCY PANIC 2nd Tier 16 FIRE PANIC 2nd Tier 17 RCVR TROUBLE 2nd Tier 17 PANEL TAMPER 2nd Tier 17 EXIT E...

Страница 5: ...2nd Tier 24 PHONE MODULE 2nd Tier 24 Exiting User Programming Mode 24 Downloader Programming 25 ToolBox Downloader Programming 25 Testing the System 25 Basic System Commands 25 Testing Sensors Zones 2...

Страница 6: ...iv...

Страница 7: ...8 or 13 071 or Wireless Learn Mode Door Window Sen sor 60 362 Wireless Learn Mode PIR Motion Sensor 60 703 95 or 60 639 RECEIVER TROUBLE set to on EXIT DELAY set to 60 seconds or less QUICK EXIT set t...

Страница 8: ...rious hardwired detectors Built In Radio Receiver Allows use of up to 20 GE Interlogix 319 5 MHz Crystal and or SAW Learn Mode wireless sensors and touchpads Built In Siren Capable of 85 dB 3m Built I...

Страница 9: ...tion then hang the back mounting plate on the screw 7 Recheck for level insert the lower screw and tighten both mounting screws 8 Install the antenna There are three antenna options to choose from Sta...

Страница 10: ...attery Pack The panel will receive its primary power from an AC class II transformer In the event of an AC power failure the panel will be powered by a battery pack containing four rechargeable NiCd b...

Страница 11: ...l You can program the panel manually using the panel keypad on site Alternately ToolBox downloader software version 5 7 or later allows you to program remotely via a modem and phone line See Downloade...

Страница 12: ...after each flash sequence before releasing the tamper switch see Figure 6 To learn the DTIM into the panel 1 Remove the DTIM cover and set it aside 2 Install the antennas See the DTIM Installation In...

Страница 13: ...tral monitoring station Phones Menu 1st Tier The PHONES menu lets you set up central station reporting for the Allegro system Phone 1 and Phone 2 2nd Tier Each 2nd tier PHONE menu contains the followi...

Страница 14: ...press and hold the 7 key until appears A star is displayed as To enter press and hold the 9 key until appears A pound is displayed as To clear phone number press Quick Exit To program Number 1 or 2 En...

Страница 15: ...hether a closing report is sent to the central station When turned on the panel sends a closing report when the system is armed To turn Closings reports on or off under Phone 1 or 2 Press to turn it o...

Страница 16: ...g is not accessi ble if a Dealer Code is pro grammed and the Installer Code is used to enter installer pro gramming mode To access the pre dial string option when a Dealer Code is programmed you must...

Страница 17: ...old the TEST RESET button until you hear 6 beeps ADD 2nd Tier DEVICES Note To override the preassigned sensor number use the arrow keys to skip to the desired sen sor number Default None When adding d...

Страница 18: ...d Table 4 on page 12 shows the words available for each field The default text for zones 2 3 are Zone 2 Front Door Zone 3 Back Door To add text 1 To select the zone you want to add text to press till...

Страница 19: ...wnloader phone num ber and with a Downloader code Call waiting services should be disabled to prevent interrupting panel communication to the down loader To program a dialing prefix that disables call...

Страница 20: ...arameters 4 digits 0 9 The duress code is a unique 4 digit access code that allows users to operate the system and at the same time instructs the panel to send a silent alarm report to the central sta...

Страница 21: ...days Set this option to 0 to turn off To set the Auto Phone Test Press enter desired number of days and then press QUIET TIME 2nd Tier TIMERS Important Fire related trouble beeps are not affected by...

Страница 22: ...s are enabled on or disabled off If enabled an immediate Police alarm will occur after the police panic buttons are pressed for two seconds and the panel displays the alarm as a police panic If the DT...

Страница 23: ...the panel will display a status mes sage only To turn the panel tamper on or off Press to turn on or off EXIT EXT 2nd Tier OPTIONS Default on UL installations off When Exit Extension is on the panel...

Страница 24: ...er arms the system without exiting the premises This can help prevent accidental alarms by deactivating interior motion sensors during occupied arming periods When this feature is on and the system is...

Страница 25: ...ork exactly as on the production version except those listed here To put the panel into demo kit mode 1 Press to turn Demo Kit on 2 Clear the panel memory see Clear Memory 1st Tier on page 21 The powe...

Страница 26: ...The panel sends a packet to the DTIM informing it to send a phone test report to the central station The report will be sent out immediately The DTIM will send a successful or failed phone test messa...

Страница 27: ...d To begin a downloader session Press until EXIT DL is displayed and then enter installer dealer or primary code to start a Downloader session User Programing Menu Items This section guides you throug...

Страница 28: ...to 9 The maintenance code is to be used in conjunction with the apartment manager keychain touchpad When a maintenance person needs access to a site protected by an Allegro he can press disarm on the...

Страница 29: ...is set to a lower level Panel will automatically leave sensor test after 15 minutes Warning beeps will sound the last minute The panel will display TEST DONE when all sensors have been tested To run a...

Страница 30: ...mode Press until EXIT is displayed and then press The current time will be displayed PANEL 2nd Tier VERSION This setting allows the user to display the panel software and hardware version installed T...

Страница 31: ...oes not exist the user or ToolBox operator sim ply calls the panel location once and listens for 10 rings The panel should answer after the tenth ring For off site access where an answering machine ex...

Страница 32: ...Q u i c k E x i t 1 A r m N o D e l a y 4 D i s a r m C h i m e 7 S i l e n t Table 6 Sensor Tripping Instructions Sensor Do This Number of Beeps DTIM Initiate a sensor test 7 8 Door Window Open the...

Страница 33: ...r s battery and replace the sensor Testing Phone Communication Perform a phone test to check the phone communication between the panel and the central moni toring station See PHONE TEST 1st Tier on pa...

Страница 34: ...t the battery voltage is only monitored during a backup battery test The panel auto matically runs a two minute backup battery test under the following conditions 1 during user sensor test 2 once ever...

Страница 35: ...alarm initiate a sensor test and then replace the indicated device battery After replacing the battery perform another sensor test to test the sensor touchpad Note If the sensor touchpad is not tested...

Страница 36: ...nd learn sensor into memory maximum zones 20 6 Sensor may be out of range Move sensor to another location Sensor reports trouble and open condition 1 Sensor tamper switch is tripped sensor cover is of...

Страница 37: ...s signal may not be reaching the panel because it is too far away from the panel or there is too much interference 1 Remove the DTIM from its mounted location and test from other locations 2 Mount th...

Страница 38: ...to verify communication between the DTIM and panel See Phone Test 2nd Tier on page 23 Downloader Download upload session fails on a pre programmed panel 1 Verify Downloader Phone Number matches ToolB...

Страница 39: ...nt Interior Interior doors Police Follower 2 3 15 Instant Interior Interior PIR motion sensors Police Follower 2 3 16 Instant Interior Interior doors Police Follower 3 17 Instant Interior PIR motion s...

Страница 40: ...sensor of this type will cause an immediate alarm if the violation occurs during an active arming level Follower A sensor of this type will cause an immediate alarm if a violation occurs during an act...

Страница 41: ...Trouble Off On for UL off on Panel Tamper On off on Exit EXT On Off for UL off on Swinger Shutdown 1 1 2 Quick Arm Off off on Quick Exit On Off for UL off on Auto Stay Arm On off on Supv Time Random...

Страница 42: ...Appendix B Reference Tables 36 Table B9 Sensor Information Sensor Number Sensor Text Sensor Type Sensor Group 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20...

Страница 43: ...none 30 sec 15 120 none none 4 digits 4 digits 4 digits 4 digits 4 digits Exit Dly 60 Sec 45 254 Auto Phn Test 0 Off 0 255 Quiet Time On Off Quiet Hour 22 0 23 Rearm Timer 0 0 12 KTP Arm Police Panic...

Страница 44: ...cy 319 5 MHz or 140 kHz Nominal Range 500 feet 150 m open air receiving range Temperature Range Storage 30 to140 F 34 to 60 C Operating 32 to 122 F 0 to 49 C Maximum Humidity 90 relative humidity nonc...

Отзывы: