32
6 Install indoor unit
When routing the piping and wiring from the left or right side of the indoor unit (as shown in the following Fig.11-5, cut off
the sections at the distribution pipe at t he pipe board of the unit base.
1 When only the power cord is led, pass through the hole
2 When the connection pipe and wire are led, pass through the hole
Wrap the connecting piping and electric cable properly (as shown in Fig. 11-6) and pass them through the piping hole;
Hang the claw at the back of the indoor unit to the clasp on the wall-mounting frame and move the unit body left and right to
see if it's secured;
Guarantee that the install height of the indoor unit should above 2.0m from the floor;
Take out two purifier filters from the auxiliary bag and install them in the unit;
Low material 2
Low material 1
Hole
Pipe outlet Plate
Power Connection Cable
Drainage
Hose
Connect Pipe
Banding Tape
Signal Control line not
for cooling only unit
Fig.11-5
Fig.11-6