Using the Air Conditioner

USING THE 

A

IR CONDITIONER

Remote Control

Ŷ

To ensure proper operation, aim the remote control at the 
signal receiver on the air conditioner.

Ŷ

The remote control signal has a range of up to 20 feet.

Ŷ

Make sure nothing is between the air conditioner and the 
remote control that could block the signal.

Ŷ

Make sure batteries are fresh and installed correctly as 
indicated on the remote control.

Do Not Operate in Freezing Outdoor Conditions

This cool-only air conditioner was not designed for freezing 
outdoor conditions.  It must not be used when the outdoor 
temperature is below freezing (32°F).

Cool Mode

8VHWKH&RROPRGHDW

Low, Med, High 

or 

Speed

 for 

FRROLQJ8VHWKH

Temperature Increase 

+

 Decrease 

 

pads to set the desired temperature between 64°F and 
86°F in 1°F increments. 

An electronic thermostat is used to maintain the room 
temperature. The compressor will cycle on and off 
to keep the room at the set level of comfort. Set the 
thermostat at a lower number and the indoor air will 
become cooler. Set the thermostat at a higher number 
and the indoor air will become warmer.

NOTE:

 If the air conditioner is off and is then turned on 

while set to a 

Cool 

setting or if turned from a fan setting 

to a

 Cool

VHWWLQJLWPD\WDNHDSSUR[LPDWHO\PLQXWHVIRU

the compressor to start and cooling to begin.

Cooling Descriptions

For Normal Cooling—

Select the 

Cool 

mode and  

High 

or 

Med

 fan with a middle set temperature.

For Maximum Cooling—

Select the 

Cool 

mode  

and

 High 

fan with a lower set temperature.

For Quieter and Nighttime Cooling—

Select the  

Cool 

mode and 

Low

 fan with a middle set temperature.

Energy Saver Mode

Controls the fan.

ON—

The fan will cycle on and off with the compressor. 

This may result in wider variations of room temperature 
and humidity. NOTE: the fan may continue to run 
for a short time or may pulse intermittently after the 
compressor cycles off to sample the room air.

OFF—

The fan runs all the time, while the compressor 

cycles on and off.

Fan Only Mode

8VHWKH)DQ2QO\0RGHDW/LJKIDQVSHHG

to provide air circulation and filtering without cooling. 
Since fan-only settings do not provide cooling, a Set 
temperature cannot be entered. The room temperature 
will appear in the display.

Auto Fan Mode

Set to 

Auto 

for the fan speed to automatically set to the 

speed needed to provide optimum comfort settings with 
the set temperature.

If the room needs more cooling, the fan speed will 
automatically increase. If the room needs less cooling, 
the fan speed will automatically decrease. 

Содержание AHS06

Страница 1: ...G THE AIR CONDITIONER Controls 4 Remote Control 5 Cool Mode 5 Energy Saver Mode 5 Air Direction 6 CARE AND CLEANING Grille and Case 6 Air Filter 6 Outdoor Coils 6 Install Batteries in Remote 6 INSTALL...

Страница 2: ...o every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you need t...

Страница 3: ...TO CONNECT ELECTRICITY Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded DO NOT use an adapter plug...

Страница 4: ...to set Press the Delay 1 24hr pad on the unit or the remote control Each touch of the Increase Decrease pads on the unit or the remote control will set the timer in 1 hour intervals To review the rema...

Страница 5: ...while set to a Cool setting or if turned from a fan setting to a Cool VHWWLQJ LW PD WDNH DSSUR LPDWHO PLQXWHV IRU the compressor to start and cooling to begin Cooling Descriptions For Normal Cooling S...

Страница 6: ...er with warm soapy water Rinse and let the filter dry before replacing it Do not clean the filter in a dishwasher CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will...

Страница 7: ...60 Hz grounded outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall outlet you plan to use is onl...

Страница 8: ...e Curtain 2 Top mounting rail Air conditioner Window locking bracket 1 Side Brackets 2 PARTS INCLUDED Appearance may vary Remote Control AHH06 AHH08 AHH10 AHH12 Bottom Seal and Side Seals 3 Not includ...

Страница 9: ...or metal The electrical outlet must be within reach of the power cord Follow the dimensions in the table and illustration for your model 2 STORM WINDOW REQUIREMENTS A storm window frame will not allow...

Страница 10: ...ve foam backed sheet Apply over side curtain and frame Side curtain foam Weather seals 4 INSTALL THE AIR CONDITIONER IN THE WINDOW A Mark the center of the window Set the air conditioner in the window...

Страница 11: ...age to windows on vinyl or other similarly constructed windows attach the window locking bracket to the window side jamb with one Type B screw B Cut the foam top window gasket to the window width C St...

Страница 12: ...does not cool as it should Indoor airflow is restricted Make sure there are not curtains blinds or furniture blocking the front of the air conditioner The temp control may not be set properly Turn th...

Страница 13: ...WKH EDVH SDQ GXULQJ KLJK KXPLGLW RU RQ UDLQ GD V 7KH ZDWHU PD RYHUIORZ DQG GULS IURP WKH outdoor side of the unit 7KH IDQ PD UXQ HYHQ ZKHQ WKH FRPSUHVVRU GRHV QRW DWHU GURSOHWV EHLQJ WKURZQ DJDLQVW WK...

Страница 14: ...14 49 7776 Notes NOTES...

Страница 15: ...settingofcircuitbreakers Failureduetocorrosiononmodelsnotcorrosion protected Damagetotheproductcausedbyimproperpowersupply voltage accident fire floodsoractsofGod Incidentalorconsequentialdamagecaused...

Страница 16: ...Q WKH 86 GEAppliances com register Parts and Accessories Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes 9 6 0DVWHU DUG DQG LVFRYHU FD...

Страница 17: ...isitos de la Ventana 9 Preparaci n del Acondicionador de Aire 9 Instalaci n del Acondicionador de Aire 10 CONSEJOS PARA LA SOLUCI N DE PROBLEMAS 12 Sonidos de Funcionamiento Normal 13 SOPORTE AL CLIEN...

Страница 18: ...eemos que usted tambi n Entre otras cosas el registro de su electrodom stico asegura que podamos entregarle informaci n importante del producto y detalles de la garant a cuando los necesite Registre s...

Страница 19: ...HOLPLQH HO WHUFHU FDEOH WLHUUD GHO FDEOH GH FRUULHQWH 3DUD VX VHJXULGDG SHUVRQDO HVWH electrodom stico debe estar adecuadamente conectado a tierra NO use un enchufe adaptador con este electrodom stico...

Страница 20: ...el acondicionador de aire se encuentre encendido se podr configurar autom ticamente para que se apague en un SHUtRGR GH HQWUH KRUDV C mo configurar Presione la tecla Delay 1 24hr 5HWUDVR HQWUH KUV en...

Страница 21: ...y que comience la refrigeraci n Descripciones de enfriamiento Para enfriamiento normal Seleccione el modo Cool Fr o y ventilador High Alto o Med Medio con una temperatura de ajuste media Para enfriami...

Страница 22: ...UR FRQ DJXD FDOLHQWH MDEyQ QMXDJXH GHMH VHFDU HO ILOWUR DQWHV GH VX UHHPSOD R 1R OLPSLH HO ILOWUR HQ XQ lavavajillas PRECAUCI N 12 XWLOLFH HO DFRQGLFLRQDGRU GH DLUH sin un filtro ya que la suciedad y...

Страница 23: ...sible GH GLODWDFLyQ GH WLHPSR GH DPSHULRV R XQ cortacircuitos El enchufe de tres p as con conexi n a tierra minimiza la posibilidad de descargas el ctricas Si el tomacorriente de la pared que usted pl...

Страница 24: ...na Cortinas DWHUDOHV Riel de montaje superior Acondicionador de aire Soporte de Cierre GH OD 9HQWDQD 6RSRUWHV DWHUDOHV PARTES INCLUIDAS La apariencia puede variar Control Remoto Sellado Inferior y Sel...

Страница 25: ...r al alcance del cable el ctrico del acondicionador de aire Siga las dimensiones de la tabla y la ilustraci n seg n su modelo 2 REQUISITOS DE UNA VENTANA DE TORMENTAS 8Q PDUFR GH YHQWDQD GH WRUPHQWDV...

Страница 26: ...als 4 INSTALE EL ACONDICIONADOR DE AIRE EN LA VENTANA A Marque el centro de la ventana Coloque el acondicionador de aire en la ventana de modo que se encuentre centrado Coloque el acondicionador de ai...

Страница 27: ...ventanas sobre vinilo o ventanas construidas de manera similar adjunte el soporte de bloqueo de la ventana a la jamba lateral de la ventana con un tornillo 7LSR B Corte la junta de gomaespuma superio...

Страница 28: ...o de aire est restringido Cerci rese de que no existe ninguna cortina persiana o mueble bloqueando el frente del acondicionador de aire El control de temperatura no est ajustado apropiadamente En los...

Страница 29: ...GtDV OOXYLRVRV R FRQ PXFKD KXPHGDG O DJXD SRGUtD GHUUDPDUVH gotear desde el lado externo de la unidad O YHQWLODGRU SRGUtD IXQFLRQDU DXQ VL HO FRPSUHVRU QR OR KDFH DV JRWLWDV GH DJXD TXH FDHQ FRQWUD OD...

Страница 30: ...49 7776 Notas NOTAS...

Страница 31: ...isyuntores Fallascomoconsecuenciadecorrosi nenmodelossin protecci ncontra sta Da osocasionadossobreelproductopornivelde suministrodevoltajeinadecuado accidente incendio inundacionesocat strofesnatural...

Страница 32: ...nces com register Piezas y Accesorios Aquellos individuos calificados para realizar el servicio t cnico de sus propios electrodom sticos podr n solicitar el env o de SLH DV R DFFHVRULRV GLUHFWDPHQWH D...

Отзывы: