GE AHF45 Скачать руководство пользователя страница 3

Operating Instructions

Electrical Safety

Grounding

This dehumidifier must be grounded.
Grounding reduces the risk of electric shock by
providing an escape wire for the electric current.
The power cord has a grounding wire with a
grounding plug. Plug it into an outlet that is
properly installed and grounded. 

WARNING

—Improper use of the grounding

plug can result in a risk of electric shock.
Call a qualified electrician if you don’t under-
stand the grounding instructions or if you are not
sure if the dehumidifier is properly grounded.
If the wall outlet is not grounded, you are
responsible for having it replaced with a properly
grounded outlet.

Do not, under any circumstances, cut or remove the
third (ground) prong from the power cord.

Adapter Plug

Because most 2-prong outlets are not grounded,
we strongly advise against using an adapter plug.
However, a temporary connection may be made
where local codes permit and if the 2-prong wall
outlet is properly grounded.
Make sure the larger prong of the adapter goes
into the larger slot to provide proper polarity.

FOR PROPER GROUNDING:

1 Screw the adapter to the outlet, using the outlet

cover screw.

2 Ground the outlet through the house wiring.

If the grounding connector breaks, 

DO NOT USE

the dehumidifier until a proper ground has
again been made.

Extension Cord

Use only a UL-listed, 3-wire grounding type, 
14 gauge, 15A, 125V appliance extension cord.

When you first use the dehumid-
ifier, turn the humidity control to
the highest setting. At this setting,
the unit will operate continuously.
Keep it at this setting for three to
four days.

When the excess moisture and 
dampness odors are gone, adjust
the control to a lower setting. Use
the dehumidifier as long as excess
moisture is present.

Humidity Control

The controls on your dehumidifier

The fan control adjusts the fan
speed. Set the fan control to 

HIGH

for maximum moisture removal.
When the humidity has been
reduced and quiet operation is 
preferred, set the fan control 
to 

LOW

.

Fan Speed 

(on some models)

3

Содержание AHF45

Страница 1: ...ions including the following This dehumidifier must be properly installed and grounded as described in this manual Never operate this dehumidifier in an area that is likely to accumulate standing water If this condition develops for your safety disconnect the power supply before stepping into the water Repair or replace immediately all electric service cords that have become frayed or otherwise da...

Страница 2: ...e Staple your receipt to the inside back cover of this manual You will need it to obtain service under warranty Start Here Before using your dehumidifier Need Help Read this manual It contains instructions to help you use and maintain your dehumidifier properly Save time and money Check the section titled If Something Goes Wrong before calling This sec tion helps you to solve common problems that ...

Страница 3: ...codes permit and if the 2 prong wall outlet is properly grounded Make sure the larger prong of the adapter goes into the larger slot to provide proper polarity FOR PROPER GROUNDING 1 Screw the adapter to the outlet using the outlet cover screw 2 Ground the outlet through the house wiring If the grounding connector breaks DO NOT USE the dehumidifier until a proper ground has again been made Extensi...

Страница 4: ...out the front grille into the room It is normal for the surrounding air to become slightly warmer as the dehumidifier operates This warming effect further reduces the relative humidity of the sur rounding air How It Works Evaporator Condenser Humidistat Humid air in Fan Dry air out Drain pan Drain connector Float Bucket Compressor There are 3 ways to remove collected water 1 Use the bucket Turn th...

Страница 5: ... outlet before cleaning To clean the case Use water and a mild detergent Do not use bleach or abrasives To clean the grille Use a vacuum attachment or brush Grille and Case After removing the air filter clean the coil on the inside with a soft brush when the soil is soft and wet DO NOT allow water to enter the electrical machine compartment through the circular opening behind the coil DO NOT spray...

Страница 6: ...n Noise Air is moving through This is normal the dehumidifier Water on Floor Connection may be loose Check the hose if one is attached Bucket not all the way in Push the bucket all the way in and make sure the float is hanging inside the bucket Did not allow enough time When first installed allow at least 3 or 4 days to remove the moisture to maintain the desired dryness Airflow is restricted Make...

Страница 7: ...cessories sent directly to their home VISA MasterCard and Discover cards are accepted Care and cleaning instructions con tained in this manual cover proce dures to be performed by any user Other servicing generally should be referred to qualified service per sonnel Caution must be exercised since improper servicing may cause unsafe operation Parts and Accessories If for some reason you are not hap...

Страница 8: ... original purchase date is needed to obtain service under warranty DEHUMIDIFIER WARRANTY What is Covered Service trips to your home to teach you how to use the product Read your Owner s Manual If you then have any questions about operating the product please contact your dealer or our Consumer Affairs office at the address below or call toll free GE Answer Center 800 626 2000 consumer information ...