background image

19

Consumer Support

Tr

oubleshooting T

ips

Operating Instructions

Safety Instructions

Installation Instructions

Air Conditioner Warranty.

For The Period Of:

We Will Replace:

One Year

Any part 

of the air conditioner which fails due to a defect in materials or workmanship. 

From the date of the

During this 

full one-year warranty, 

we will also provide, 

free of charge, 

all labor and in-home

original purchase

service to replace the defective part.

Five Years

Any part of the sealed refrigerating system 

(the compressor, condenser, evaporator and

From the date of the

all connecting tubing) which fails due to a defect in materials or workmanship. During this

original purchase

four-year additional warranty, 

we will also provide, 

free of charge, 

all labor and in-home service 

to replace the defective part.

Service trips to your home to teach you how to 
use the product.

Improper installation. If you have an installation problem,
or if the air conditioner is of improper cooling capacity
for the intended use, contact your dealer or installer. 
You are responsible for providing adequate electrical
connecting facilities.

Failure of the product resulting from modifications to 
the product or due to unreasonable use including failure
to provide reasonable and necessary maintenance.

In commercial locations labor necessary to move the 
unit to a location where it is accessible for service 
by an individual technician.

Replacement of house fuses or resetting of circuit
breakers.

Failure due to corrosion on models not corrosion-
protected.

Damage to the product caused by improper power supply
voltage, accident, fire, floods or acts of God.

Incidental or consequential damage caused by possible
defects with this air conditioner.

What Is Not Covered:

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home
use within the USA. In Alaska, the warranty excludes the cost of shipping or service calls to your home.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state. To know what your
legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Warrantor: General Electric Company. Louisville, KY 40225

All warranty service provided by our Factory Service Centers, 
or an authorized Customer Care

®

technician. To schedule service,

on-line, 24 hours a day, visit us at GEAppliances.com, or call
800.GE.CARES (800.432.2737).

Staple your receipt here. 

Proof of the original purchase

date is needed to obtain service

under the warranty.

Содержание AGN18

Страница 1: ...Troubleshooting Tips 15 16 Normal Operating Sounds 16 Consumer Support Consumer Support 20 Product Registration 17 18 Warranty 19 3828A20296H 49 7448 11 02 JR Owner s Manual and Installation Instructi...

Страница 2: ...w must be removed prior to product disposal If you are getting rid of an old product with refrigerants check with the company handling disposal about what to do SAFETY PRECAUTIONS Do not under any cir...

Страница 3: ...de to a properly grounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall outl...

Страница 4: ...s of room temperature and humidity Normally used when the room is unoccupied Note The fan will continue to run for a short time after the compressor cycles off OFF The fan runs all the time while the...

Страница 5: ...set temperature For Maximum Cooling Select the COOL mode and HIGH F3 fan with a lower set temperature For Quieter Nighttime Cooling Select the COOL mode and LOW F1 fan with a middle set temperature N...

Страница 6: ...number available on your knob For Quieter Nighttime Cooling Select LOW COOL with the temp control at midpoint Temp Controls The temp control is used to maintain the room temperature The compressor wi...

Страница 7: ...esired air direction is obtained then move it to OFF For continuous side to side air circulation cool settings only set the Circulaire switch to ON Air Direction Up and Down Fingertip pressure on the...

Страница 8: ...ION DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance 2 1 Outdoor Coils The coils on the outdoor side of the air conditioner should be check...

Страница 9: ...cord Do not change the plug on the power cord of this air conditioner Aluminum house wiring may present special problems consult a qualified electrician Before You Begin Some models require 115 120 v...

Страница 10: ...pe D 2 Carriage Bolt 2 Lock Nut 4 Window locking bracket Frame guide 2 Top mounting rail Top mounting rail seal strip Right accordion panel Foam top window gasket Window sash seal Left accordion panel...

Страница 11: ...od masonry or metal The electrical outlet must be within reach of the power cord 18 min 29 to 41 With accordion panels 261 4 min Without accordion panels Storm Window Requirements A storm window frame...

Страница 12: ...Insert the frames for the accordion panels into the top mounting rail and the frame guides Attach the accordion panels to the side of the case using 5 type A screws D C B A Remove the Air Conditioner...

Страница 13: ...aligning the center front on the bottom with the centerline marked on the window stool Close the window making sure the window sash is behind the top mounting rail Using the larger diameter hole in t...

Страница 14: ...the grille in until it snaps into place Lift the inlet grille and secure the front frame with a type A screw Lower the inlet grille into place D C B A 8 Install the Window Locking Bracket and the Foam...

Страница 15: ...heck for open furnace floor registers and cold air returns Set the air conditioner s vent to the closed position Cooling coils have iced up See Air conditioner freezing up below Air conditioner Ice bl...

Страница 16: ...picked up and thrown against the condenser on rainy days or when the humidity is high This design feature helps remove moisture and improve efficiency You may hear the thermostat click when the compr...

Страница 17: ...will be completely satisfied with our service protection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwa...

Страница 18: ...ure that your product is registered or register online at www GEAppliances com 1 2 3 Model Number Serial Number Cut here Complete and mail your Consumer Product Ownership Registration today Have the p...

Страница 19: ...provide reasonable and necessary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician Replacement of house...

Страница 20: ...arranty and learn about special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Ho...

Страница 21: ...para la identificaci n y reparaci n de problemas 15 16 Sonidos normales de operaci n 16 Apoyo al consumidor Apoyo al consumidor 20 Garant a 19 3828A20296H 49 7448 11 02 JR Manual del Propietario e Ins...

Страница 22: ...ederan deben ser removidos antes de desecharlos Si usted planea deshacerse de alg n producto que contenga refrigerantes p ngase en contacto con la compa a que se encarga de recoger su basura para que...

Страница 23: ...iente listado UL disponible en la mayor a de las ferreter as La ranura mayor en el adaptador debe estar alineada con la p a mayor en la pared para proporcionar una polaridad apropiada en la conexi n d...

Страница 24: ...ue el compresor entre en el ciclo de apagado OFF APAGADO El ventilador funciona todo el tiempo mientras el compresor hace ciclo entre encendido y apagado Esta funci n debe estar colocada en OFF APAGAD...

Страница 25: ...ajuste menor Para enfriamiento silencioso enfriamiento nocturno Seleccione el modo de ventilador COOL FR O y LOW F1 BAJO con una temperatura de ajuste media NOTA Si usted cambia de un ajuste COOL FR...

Страница 26: ...on el control de temperatura en un n mero mayor disponible en su teclado Para enfriamiento silencioso durante la noche Seleccione LOW COOL ENFRIAMIENTO BAJO con el control de temperatura en el nivel m...

Страница 27: ...IRCULADOR DE AIRE a la posici n ON ENCENDIDO y d jelo as Direcci n del aire Hacia arriba y hacia abajo Una presi n sencilla con los dedos en parte posterior de la persianita horizontal ajustar la dire...

Страница 28: ...N NO opere el acondicionador de aire sin el filtro debido a que la suciedad y las pelusas lo obstruir n y reducir n su rendimiento 2 1 Bobinas para exteriores Las bobinas en el lado exterior del acond...

Страница 29: ...tricista calificado Antes de comenzar Algunos modelos requieren tomacorrientes de 115 120 voltios de corriente alterna y 60 Hz conectado a tierra protegido con un fusible de dilataci n de tiempo de 15...

Страница 30: ...e 4 Soporte de cierre de la ventana Gu a del marco 2 Riel de montaje superior Cinta de sellado del riel de montaje Panel de acorde n derecho Parte superior de la espuma de la junta de la ventana Banda...

Страница 31: ...m nimo sin paneles de acorde n 1 Requisitos de una ventana de tormentas Un marco de ventana de tormentas no permitir que el acondicionador de aire se incline hacia el exterior y evitar que drene aprop...

Страница 32: ...arcos para los paneles de acorde n en el riel de montaje superior y las gu as del marco Una los paneles de acorde n al lado de la caja usando 5 tornillos tipo A D C B A Retire el acondicionador de air...

Страница 33: ...dose de que la banda est detr s del riel de montaje superior Usando el agujero de mayor di metro en la caja pegue los soportes a la caja usando 2 tornillos tipo D y 2 tuercas se cierre en cada lado Aj...

Страница 34: ...rrilla hasta que encaje en su lugar Levante la parrilla de entrada y aseg rela al marco frontal con un tornillo tipo A Baje la parrilla de entrada a su lugar D C B A 8 Instale el soporte de cierre de...

Страница 35: ...la calefacci n no est n abiertos y se encuentran retornando el aire fr o Coloque la ventanilla del acondicionador de aire en la posici n cerrada Las bobinas de enfriamiento Ver Acondicionador de aire...

Страница 36: ...uando el compresor hace ciclo entre encendido y apagado El agua se acumula en la bandeja durante d as lluviosos o con mucha humedad El agua podr a derramarse y gotear desde el lado externo de la unida...

Страница 37: ...17 Apoyo al consumidor Soluci n de problemas Instrucciones de operaci n Instrucciones de seguridad Instrucciones de instalaci n Notas...

Страница 38: ...18 Notas Apoyo al consumidor Soluci n de problemas Instrucciones de operaci n Instrucciones de seguridad Instrucciones de instalaci n...

Страница 39: ...para revisi n por parte de un t cnico individual Reemplazo de fusibles de la casa o reajuste del sistema de circuitos Fallos debido a la corrosi n en modelos que no est n protegidos contra la corrosi...

Страница 40: ...a detalles sobre descuentos especiales disponibles mientras su garant a est a n activa Puede comprarla en l nea en cualquier momento o llamar al 800 626 2224 durante horas normales de oficina GE Consu...

Отзывы: