6.2.17 ID-## Drive Information
Par. No. # Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
ID-0#
ID-00
Operating Hours
0 h
All set-ups
FALSE
74
Uint32
ID-01
Running Hours
0 h
All set-ups
FALSE
74
Uint32
ID-02
kWh Counter
0 kWh
All set-ups
FALSE
75
Uint32
ID-03
Power Up's
0 N/A
All set-ups
FALSE
0
Uint32
ID-04
Over Temp's
0 N/A
All set-ups
FALSE
0
Uint16
ID-05
Over Volt's
0 N/A
All set-ups
FALSE
0
Uint16
ID-06
Reset kWh Counter
[0] Do not reset
All set-ups
TRUE
-
Uint8
ID-07
Reset Running Hours Counter
[0] Do not reset
All set-ups
TRUE
-
Uint8
ID-08
Number of Starts
0 N/A
All set-ups
FALSE
0
Uint32
ID-1#
ID-10
Trending Source
0
2 set-ups
TRUE
-
Uint16
ID-11
Trending Interval
ExpressionLimit
2 set-ups
TRUE
-3
TimD
ID-12
Trigger Event
[0] False
1 set-up
TRUE
-
Uint8
ID-13
Trending Mode
[0] Trend always
2 set-ups
TRUE
-
Uint8
ID-14
Samples Before Trigger
50 N/A
2 set-ups
TRUE
0
Uint8
ID-2#
ID-20
Historic Log: Event
0 N/A
All set-ups
FALSE
0
Uint8
ID-21
Historic Log: Value
0 N/A
All set-ups
FALSE
0
Uint32
ID-22
Historic Log: Time
0 ms
All set-ups
FALSE
-3
Uint32
ID-23
Historic Log: Date and Time
ExpressionLimit
All set-ups
FALSE
0
TimeOfDay
ID-3#
ID-30
Alarm Log: Error Code
0 N/A
All set-ups
FALSE
0
Uint8
ID-31
Alarm Log: Value
0 N/A
All set-ups
FALSE
0
Int16
ID-32
Alarm Log: Time
0 s
All set-ups
FALSE
0
Uint32
ID-33
Alarm Log: Date and Time
ExpressionLimit
All set-ups
FALSE
0
TimeOfDay
ID-4#
ID-40
Drive Type
0 N/A
All set-ups
FALSE
0
VisStr[6]
ID-41
Power Section
0 N/A
All set-ups
FALSE
0
VisStr[20]
ID-42
Voltage
0 N/A
All set-ups
FALSE
0
VisStr[20]
ID-43
Software Version
0 N/A
All set-ups
FALSE
0
VisStr[5]
ID-44
GE Model Number
0 N/A
All set-ups
FALSE
0
VisStr[40]
ID-45
Actual Typecode String
0 N/A
All set-ups
FALSE
0
VisStr[40]
ID-46
GE Product No.
0 N/A
All set-ups
FALSE
0
VisStr[8]
ID-47
GE Power Card Model No
0 N/A
All set-ups
FALSE
0
VisStr[8]
ID-48
Keypad ID Number
0 N/A
All set-ups
FALSE
0
VisStr[20]
ID-49
SW ID Control Card
0 N/A
All set-ups
FALSE
0
VisStr[20]
ID-5#
ID-50
SW ID Power Card
0 N/A
All set-ups
FALSE
0
VisStr[20]
ID-51
Drive Serial Number
0 N/A
All set-ups
FALSE
0
VisStr[10]
ID-53
Power Card Serial Number
0 N/A
All set-ups
FALSE
0
VisStr[19]
ID-6#
ID-60
Option Mounted
0 N/A
All set-ups
FALSE
0
VisStr[30]
ID-61
Option SW Version
0 N/A
All set-ups
FALSE
0
VisStr[20]
ID-62
Option Ordering No
0 N/A
All set-ups
FALSE
0
VisStr[8]
ID-63
Option Serial No
0 N/A
All set-ups
FALSE
0
VisStr[18]
ID-9#
ID-92
Defined Parameters
0 N/A
All set-ups
FALSE
0
Uint16
ID-93
Modified Parameters
0 N/A
All set-ups
FALSE
0
Uint16
How to Program
AF-600 FP High Power Operating Instructions