IMPORTANT SAFETY INFORMATION .

READ ALL INSTRUCTIONS BEFORE USING

.

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock

or personal injury.

n

 

 Use this appliance only for its intended 

purpose as described in this Owner’s 

Manual . 

n

 

 This air conditioner must be properly 

installed in accordance with the Installation 

Instructions before it is used .

 

n

  

Never unplug your air conditioner by pulling 

on the power cord . Always grip plug firmly 

and pull straight out from the receptacle . 

n

  

Replace immediately all electric service 

cords that have become frayed or otherwise 

damaged . A damaged power supply cord 

must be replaced with a new power supply 

cord obtained from the manufacturer and 

not repaired . Do not use a cord that shows 

cracks or abrasion damage along its length 

or at either the plug or connector end . 

n

 

 Turn the unit 

OFF 

and unplug your air 

conditioner before cleaning

 . 

 GE does not support any servicing of the 

air conditioner . We strongly recommend 

that you do not attempt to service the air 

conditioner yourself .

n

  

For your safety…do not store or use 

combustible materials, gasoline or other 

flammable vapors or liquids in the vicinity  

of this or any other appliance .

 All air conditioners contain refrigerants, 

which under federal law must be removed 

prior to product disposal . If you are getting 

rid of an old product with refrigerants, check 

with the company handling disposal about 

what to do .

 

If the receptacle does not match the plug, 

the receptacle must be changed out by a 

qualified electrician

 .

 

These R410A air conditioning systems 

require contractors and technicians to  

use tools, equipment and safety standards 

approved for use with this refrigerant .  

DO NOT use equipment certified for  

R22 refrigerant only .

SAFETY PRECAUTIONS

Do not, under any circumstances, cut or remove 

the third (ground) prong from the power cord.  

For personal safety, this appliance must be 

properly grounded.

  DO NOT use an adapter plug with this 

appliance .

The power cord of this appliance is equipped 

with a 3-prong (grounding) plug which mates 

with a standard 3-prong (grounding) wall outlet 

to minimize the possibility of electric shock 

hazard from this appliance .
Power cord includes a current interrupter device . 

A test and reset button is provided on the plug 

case . The device should be tested on a periodic 

basis by first pressing the 

TEST 

button and 

then the 

RESET

 button while plugged into the 

outlet . If the 

TEST

 button does not trip or if the 

RESET

 button will not stay engaged, discontinue 

use of the air conditioner and contact a qualified 

service technician .

Have the wall outlet and circuit checked by  

a qualified electrician to make sure the outlet  

is properly grounded .
Where a 2-prong wall outlet is encountered,  

it is your personal responsibility and obligation to 

have it replaced with a properly grounded  

3-prong wall outlet .
The air conditioner should always be plugged 

into its own individual electrical outlet which has 

a voltage rating that matches the rating plate .
This provides the best performance and also 

prevents overloading house wiring circuits which 

could cause a fire hazard from overheated wires .
See the Installation Instructions, 

Electrical 

Requirements

 section for specific electrical 

connection requirements

 . 

HOW TO CONNECT ELECTRICITY

Содержание AEZ12AP

Страница 1: ...ructions Write the model and serial numbers here Model _________________________ Serial __________________________ Find these numbers on a label on the side of the air conditioner Air Conditioners GEA...

Страница 2: ...fied electrician n These R410A air conditioning systems require contractors and technicians to use tools equipment and safety standards approved for use with this refrigerant DO NOT use equipment cert...

Страница 3: ...OLLOW THIS SAFETY INFORmATION CAREFULLY SAVE THESE INSTRUCTIONS RISK OF FIRE Could cause serious injury or death DO NOT use an extension cord with this Window Air Conditioner DO NOT use surge protecto...

Страница 4: ...turn on while setting Fan Speed Pads Use to set the fan speed to Low Med High or Auto on the unit NOTE On the remote control use the fan speed Increase Decrease pads to set the fan speeds to Low Med...

Страница 5: ...set temperature Energy Saver Mode Controls the fan ON The fan will cycle on and off with the compressor This results in wider variations of room temperature and humidity Normally used when the room is...

Страница 6: ...ng it back into position NOTES n Use 2 AAA 1 5 volt alkaline batteries Do not use rechargeable batteries n Remove the batteries from the remote control if the system is not going to be used for a long...

Страница 7: ...mizes the possibility of electric shock hazard If the wall outlet you plan to use is only a 2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong wall outlet So...

Страница 8: ...ation instructions Right accordion panel Foam top window gasket Left accordion panel Screw 6 Window sash seal Air conditioner Window locking bracket 1 PARTS inCLuDeD Appearance may vary Frame locking...

Страница 9: ...anels if needed to fit in a narrow window See the window opening dimensions All supporting parts must be secured to firm wood masonry or metal The electrical outlet must be within reach of the power c...

Страница 10: ...ly constructed windows attach the window locking bracket to the window side jamb with one screw B C Wood Vinyl 3 Screws C 10 inSTALL THe AiR ConDiTioneR in THe WinDoW Place the air conditioner on the...

Страница 11: ...Make sure there are no curtains blinds or furniture not cool as it should blocking the front of the air conditioner The temp control may On models with touch pads In the Cool mode press the not be set...

Страница 12: ...12 Notes...

Страница 13: ...13 Notes...

Страница 14: ...14 Notes...

Страница 15: ...and packing materials n Return the product to the retail location where it was purchased n include in the package a copy of the sales receipt or other evidence of date of original purchase Also print...

Страница 16: ...ceeding owner for products purchased in Canada for home use within Canada Some provinces do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion may not...

Страница 17: ...istrement du titre de propri t 31 32 Inscrivez ici les num ros de mod le et de s rie Num ro de mod le ____________________ Num ro de S rie _____________________ Vous trouverez ces num ros sur l tiquet...

Страница 18: ...cien qualifi n Ces syst mes de climatisation R410A n cessitent que les entrepreneurs et techniciens adoptent des outils du mat riel et des normes de s curit approuv s pour utilisation avec ce r frig r...

Страница 19: ...CONSIGNES DE S CURIT CONSERVEZ CES INSTRUCTIONS UTILISATION DE RALLONGES RISQUE D INCENDIE Peut occasionner des blessures graves ou la mort NE PAS utiliser de rallonge avec ce climatiseur NE PAS util...

Страница 20: ...t s allume lors du glage Touches de vitesse du ventilateur Sont utilis es pour r gler la vitesse du ventilateur de l appareil sur Low faible Med moyenne High elev e ou Auto automatique REMARQUE Sur la...

Страница 21: ...ateur se met en marche et s arr te en m me temps que le compresseur Ceci permet une plus grande variation de la temp rature et du taux d humidit dans la pi ce Est en g n ral utilis lorsque la pi ce es...

Страница 22: ...atiseur doivent tre r guli rement v rifi s S ils sont obstru s par des poussi res ou de la suie il est possible de les faire nettoyer par des professionnels A propos des commandes du climatiseur Eteig...

Страница 23: ...remplacer par une prise triphas e correctement mise la terre Certains mod les n cessitent une prise mise la terre de 230 208 Volts AC prot g e par un fusible action diff r e ou par un disjoncteur Ces...

Страница 24: ...lage de la fen tre 1 PI CES INCLUES L aspect peut varier Ferrure de verrouillage de cadre 2 Panneau en accord on droit Joint d tanch it sup rieur en mousse de la fen tre Panneau en accord on gauche Jo...

Страница 25: ...accord on gauche et un panneau en accord on droit Assurez vous d utiliser le panneau appropri pour chaque c t Faites glisser les panneaux en accord on gauche et droit dans les rails de montage inf rie...

Страница 26: ...e se fissure percez des avant trous avant de visser les vis 5 A B 2 ferrures de verrouillage de cadre PR PARATION DE LA FEN TRE D coupez le joint de la fen tre guillotine la longueur ad quate D collez...

Страница 27: ...re En mode Cool frais appuyez sur la touche Decrease pad n est pas bien r gl Sur les mod les dot s de boutons de commandes tournez le bouton de temp rature sur une valeur plus lev e Le filtre air est...

Страница 28: ...28 Notes...

Страница 29: ...Notes 29...

Страница 30: ...30 Notes...

Страница 31: ...31 Notes...

Страница 32: ...32 Notes...

Страница 33: ...ial est n cessaire pour faire une r clamation sous garantie n Emballez correctement votre appareil Nous vous recommandons d utiliser le carton et le mat riel d emballage d origine n Ramenez le produit...

Страница 34: ...rs peuvent recevoir pi ces et accessoires directement la maison cartes VISA MasterCard et Discover accept es Les proc dures expliqu es dans le pr sent manuel peuvent tre ex cut es par n importe quel u...

Страница 35: ...al consumidor Garant a 46 Servicio al consumidor 47 35 Escriba los n meros de modelo y serie aqu de Modelo_________________ de Serie ___________________ Puede encontrar estos n meros en una etiqueta e...

Страница 36: ...e reemplazar el recept culo n Estos sistemas de acondicionadores de aire R410A requieren que los contratistas y t cnicos usen herramientas equipos y est ndares de seguridad aprobados para su uso con e...

Страница 37: ...S INSTRUCCIONES 37 USO DE PROLONGADORES RIESGO DE INCENDIO Podr a ocasionar lesiones graves o la muerte NO use un prolongador con este Acondicionador de Aire de Ventana NO use protectores contra picos...

Страница 38: ...de aire est encendido puede ajustarse para que se apague autom ticamente dentro de 1 a 24 horas C mo realizar el ajuste Pulse la tecla Delay 1 24hr Retardo 1 24h en la unidad o Delay pad Retardo del...

Страница 39: ...lo ventilador Energy Saver Mode Modo de ahorro de energ a Controla el ventilador ON ENCENDIDO El ventilador har un ciclo de encendido y apagado con el compresor Este resulta en variaciones mayores en...

Страница 40: ...es de colocarlo otra vez en su lugar No lave el filtro en un lavavajillas PRECAUCI N NO OPERE el acondicionador de aire sin el filtro debido a que la suciedad y las pelusas lo obstruir n y reducir n s...

Страница 41: ...acondicionador de aire Los cables caseros de aluminio podr an presentar problemas especiales Consulte a un t cnico electricista calificado ANtES DE INICIAR Lea estas instrucciones completa y cuidados...

Страница 42: ...ivel Tijeras o cuchilla Un destornillador con hoja plana Panel de acorde n derecho Empaque superior de espuma de la ventana Panel de acorde n izquierdo Tornillo 6 Sello del marco de la ventana Acondic...

Страница 43: ...arco de la ventana GRuESo Para determinar el grueso coloque un pedazo de madera en el umbral para hacerla 1 2 m s alta que la parte superior del marco de la ventana de tormentas o del marco vinilo P g...

Страница 44: ...el soporte para bloqueo de ventana a el marco de la ventana con uno tornillo para prevenir da o a la ventana y vidro quebrado B C Madera Vinilo INStALE EL ACoNDICIoNADoR DE AIRE EN LA VENtANA Coloque...

Страница 45: ...Cerci rese de que los registros de la calefacci n no est n abiertos y se encuentran retornando el aire fr o Las bobinas de enfriamiento Ver Acondicionador de aire congel ndose m s adelante se congelar...

Страница 46: ...uitos n Fallo debido a la corrosi n en modelos que no est n protegidos contra la corrosi n n Da o al producto causado por voltaje inapropiado hacia el equipo accidentes incendios inundaciones o actos...

Страница 47: ...onas con dificultades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Piezas y accesorios GEAppliances com Aquellos individuos con la calificaci n necesaria para reparar sus propios electrodom...

Страница 48: ...Suite 310 1 Factory Lane Moncton N B E1C 9M3 Parts and Accessories In the U S A GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to th...

Отзывы: