GE AER08 Series Скачать руководство пользователя страница 5

 

GEAppliances.com

Cool Mode

Use the 

Cool

 mode at 

Low, Med, High

 or 

Auto Fan 

Speed

 for cooling. Use the 

Temperature Increase 

Ÿ

 

/ Decrease 

ź

 pads to set the desired temperature 

between 64°F and 86°F in 1°F increments. 
An electronic thermostat is used to maintain the room 

temperature. The compressor will cycle on and off 

to keep the room at the set level of comfort. Set the 

thermostat at a lower number and the indoor air will 

become cooler. Set the thermostat at a higher number 

and the indoor air will become warmer.

NOTE: 

If the air conditioner is off and is then turned on  

while set to a 

Cool

 setting or if turned from a fan setting 

to a 

Cool 

setting, it may take approximately 3 minutes 

for the compressor to start and cooling to begin.

Cooling Descriptions

For Normal Cooling

³6HOHFWWKH

Cool 

mode and  

High

 or 

Med

 fan with a middle set temperature.

For Maximum Cooling

³6HOHFWWKH

Cool

 mode  

and 

High

 fan with a lower set temperature.

For Quieter and Nighttime Cooling

³6HOHFWWKH

 

Cool 

mode and

 Low 

fan with a middle set 

temperature.

Fan Only Mode

Use the Fan Only Mode at Low, Med or High fan 

speed to provide air circulation and filtering without 

cooling. Since fan-only settings do not provide 

cooling, a Set temperature cannot be entered. The 

room temperature will appear  

in the display.

NOTE: 

Auto Fan Speed cannot be used when in the  

Fan Only 

Mode.

 

Energy Saver Mode

Set to Auto fan speed for the fan speed to 
automatically set to the speed needed to provide 
optimum comfort settings with the set temperature.   
If the room needs more cooling, the fan speed  
will automatically increase. If the room needs less 
cooling, the fan speed will automatically decrease. 

NOTE: 

Auto Fan Speed cannot be used when in the  

Fan Only

 

Mode.

 

Auto Fan Speed

Do Not Operate in Freezing Outdoor 

Conditions

This cool-only air conditioner was not designed for 

freezing outdoor conditions. It must not be used in 

freezing outdoor conditions.

In the case of a power outage or interruption, the 
unit will automatically restart in the settings last 
used after the power is restored. If the

 Delay 1–24hr 

feature was set, it will resume countdown. You may 
need to set a new time if desired.

Power Outage Recovery Feature

„

To ensure proper operation, aim the remote 
control at the signal receiver on the air 
conditioner.

„

 

Make sure nothing is between the air conditioner 
and the remote control that could block the 
signal.

„

 

The remote control signal has a range of  
up to 20 feet.

„

 

Make sure batteries are fresh and installed 
correctly as indicated on the remote control.

„

 

Remote contains a magnet allowing it to attach 
to metal surfaces.

Remote Control

This mode optimizes the cooling power of your air 

conditioner, thereby saving you energy. Once the 

set point temperature has been reached, the fan 

will cycle off to save energy. The fan will cycle back 

on periodically to insure all cooling capacity in the 

system is used. This mode is the default mode for the 

unit. Each time the unit is powered off, it will restart 

in 

Energy Saver

 mode 

ON

. This includes 

Delay 

timer 

mode. The first time the unit is turned on, the settings 

will be 70° and 

Low

 fan. You can adjust the fan 

speed and temperature to your personal comfort.

Energy Saver ON

³

Helps minimize electricity use. 

It is normal for the fan to cycle off and then back 

on in this mode. This on/off cycle can repeat 

multiple times. Because the fan will cycle off, you 

may notice a variation in room temperature and 

humidity.

Energy Saver OFF

³

When this mode is not engaged, 

the fan will run continuously, and in 

Cool

 mode the 

compressor will cycle on and off to maintain room 

temperature.

5

Содержание AER08 Series

Страница 1: ...umbers here Model _________________________ Serial __________________________ Find these numbers on a label on the side of the air conditioner Air Conditioners GEAppliances com Room As an ENERGY STAR...

Страница 2: ...trician These R410A air conditioning systems require contractors and technicians to use tools equipment and safety standards approved for use with this refrigerant DO NOT use equipment certified for R...

Страница 3: ...AREFULLY SAVE THESE INSTRUCTIONS WARNING USE OF EXTENSION CORDS RISK OF FIRE Could cause serious injury or death DO NOT use an extension cord with this Window Air Conditioner DO NOT use surge protecto...

Страница 4: ...te control Each touch of the Increase Decrease pads on the unit or the Increase Decrease pads on the remote control will set the timer in 1 hour intervals The Set light will turn on while setting To r...

Страница 5: ...n in the Fan Only Mode Auto Fan Speed Do Not Operate in Freezing Outdoor Conditions This cool only air conditioner was not designed for freezing outdoor conditions It must not be used in freezing outd...

Страница 6: ...ide of the air conditioner should be checked regularly If they are clogged with dirt or soot they may be professionally cleaned About the controls on the air conditioner GEAppliances com Turn the air...

Страница 7: ...your responsibility to have it replaced with a properly grounded 3 prong wall outlet Some models require 230 208 volt AC protected with a time delay fuse or circuit breaker These models should be ins...

Страница 8: ...Right accordion panel Type A 4 Type B 6 Foam top window gasket Left accordion panel Window sash seal Top mounting rail Air conditioner Window locking bracket 1 PARTS INCLUDED Appearance may vary Top m...

Страница 9: ...o determine the thickness place a piece of wood on the sill to make it 1 2s higher than the top of the storm window frame or the vinyl frame Attach securely with nails or screws provided by the instal...

Страница 10: ...lant to the outside Extend the left and right accordion panels to the vertical window sashes and attach through the holes in the panels with 5 Type B screws as appropriate 6 A B PREPARE THE WINDOW Cut...

Страница 11: ...ure there are no curtains blinds or furniture not cool as it should blocking the front of the air conditioner The temp control may On models with touch pads In the Cool mode press the not be set corre...

Страница 12: ...le for service by an individual technician Replacement of house fuses or resetting of circuit breakers Failure due to corrosion on models not corrosion protected Damage to the product caused by improp...

Страница 13: ...client le Assistance la client le 26 Garantie 25 Inscrivez ici les num ros de mod le et de s rie Num ro de mod le ____________________ Num ro de S rie _____________________ Vous trouverez ces num ros...

Страница 14: ...lifi Ces syst mes de climatisation R410A n cessitent que les entrepreneurs et techniciens adoptent des outils du mat riel et des normes de s curit approuv s pour utilisation avec ce r frig rant N util...

Страница 15: ...ONSIGNES DE S CURIT CONSERVEZ CES INSTRUCTIONS UTILISATION DE RALLONGES RISQUE D INCENDIE Peut occasionner des blessures graves ou la mort NE PAS utiliser de rallonge avec ce climatiseur 1 3 6 XWLOLVH...

Страница 16: ...mmer Appuyez sur la touche Delay 1 24hr D lai de 1 24 heures de l appareil ou Delay pad Touches de D lai de la t l commande Chaque fois que vous effleurez les touches Increase Decrease sur l appareil...

Страница 17: ...automatiquement apr s r tablissement de l alimentation lectrique et conserve les derniers r glages utilis s Si la fonction Delay 1 24hr D lai de 1 24 heures tait utilis e l appareil reprend son compte...

Страница 18: ...t de l appareil jusqu ce que le filtre soit sorti Pour retirer Ouvrez la grille d entr e en tirant vers le bas sur les languettes des coins sup rieurs de la grille d entr e jusqu ce que la grille soit...

Страница 19: ...cer par une prise triphas e correctement mise la terre Certains mod les n cessitent une prise mise la terre de 230 208 Volts AC prot g e par un fusible action diff r e ou par un disjoncteur Ces mod le...

Страница 20: ...t d tanch it sup rieur en mousse de la fen tre Panneau en accord on gauche Joint d tanch it de la fen tre guillotine Rail de montage sup rieur Climatiseur Ferrure de verrouillage de la fen tre 1 PI CE...

Страница 21: ...FEN TRE Le cadre de la contre fen tre emp che le climatiseur de pencher vers l ext rieur et donc de se drainer correctement Pour r gler ce probl me fixez un morceau de bois au rebord de la fen tre MOR...

Страница 22: ...Ins rez la mousse entre la vitre et la fen tre pour emp cher l air et les insectes de p n trer dans la pi ce NOTE Si le joint d tanch it fourni ne s adapte pas votre fen tre procurez vous localement...

Страница 23: ...mode Cool frais appuyez sur la touche Decrease pad n est pas bien r gl Sur les mod les dot s de boutons de commandes tournez le bouton de temp rature sur une valeur plus lev e Le filtre air est sale...

Страница 24: ...24 Notes...

Страница 25: ...appareil jusqu un emplacement o il est accessible par un technicien particulier Le remplacement des fusibles de la maison ou la r activation des disjoncteurs Les pannes occasionn es par la corrosion s...

Страница 26: ...eptions de cuisine pour les personnes handicap es Dans le cas de personnes malentendantes veuillez composer le 800 TDD GEAC 800 833 4322 Pi ces et accessoires GEApplianceParts com Les personnes ayant...

Страница 27: ...37 Servicio al consumidor Garant a 38 Apoyo al consumidor 39 Escriba los n meros de modelo y serie aqu de Modelo_________________ de Serie ___________________ Puede encontrar estos n meros en una etiq...

Страница 28: ...mplazar el recept culo Estos sistemas de acondicionadores de aire R410A requieren que los contratistas y t cnicos usen herramientas equipos y est ndares de seguridad aprobados para su uso con este ref...

Страница 29: ...STAS INSTRUCCIONES USO DE PROLONGADORES RIESGO DE INCENDIO Podr a ocasionar lesiones graves o la muerte NO use un prolongador con este Acondicionador de Aire de Ventana NO use protectores contra picos...

Страница 30: ...el acondicionador de aire est encendido puede ajustarse para que se apague autom ticamente dentro de 1 a 24 horas C mo realizar el ajuste Pulse la tecla Delay 1 24hr Retardo 1 24h en la unidad o Dela...

Страница 31: ...a Indique la opci n en Velocidad de ventilador autom tica para definir autom ticamente la velocidad necesaria para proporcionar una configuraci n de comodidad ptima con la temperatura elegida Si la h...

Страница 32: ...controles en el acondicionador de aire Apague el acondicionador de aire y retire el enchufe del tomacorriente de la pared antes de limpiar Para limpiar use agua y un detergente suave No use cloro o m...

Страница 33: ...e acondicionador de aire Los cables caseros de aluminio podr an presentar problemas especiales Consulte a un t cnico electricista calificado ANTES DE INICIAR Lea estas instrucciones completa y cuidado...

Страница 34: ...a Panel de acorde n derecho Tipo A 4 Tipo B 6 Junta de espuma superior de la ventana Panel de acorde n izquierdo Sello de la banda de la ventana Riel de montaje superior Acondicionador de aire Soporte...

Страница 35: ...l exterior y evitar que drene apropiadamente Parasolucionareste problema adhiera un pedazo de madera a el umbral PEDAZOS DE MADERA ANCHO 2s LONGITUD Lo suficientemente largo como para ajustar en el in...

Страница 36: ...entana Rellene la espuma entre el vidrio y la ventana para evitar que aire e insectos se introduzcan en la habitaci n NOTA Si la junta provista no es adecuada para su ventana obtenga el material aprop...

Страница 37: ...ndo Cerci rese de que los registros de la calefacci n no est n abiertos y se encuentran retornando el aire fr o Las bobinas de enfriamiento Ver Acondicionador de aire congel ndose m s adelante se cong...

Страница 38: ...cubierto Esta garant a se extiende al comprador original y cualquier comprador posterior de productos comprados para uso residencial dentro de Estados Unidos Si el producto est situado en un rea que n...

Страница 39: ...personas con dificultades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Piezas y accesorios GEAppliances com Aquellos individuos con la calificaci n necesaria para reparar sus propios electro...

Страница 40: ...es check out our Website today For the hearing impaired please call 800 TDD GEAC 800 833 4322 Parts and Accessories GEApplianceParts com Individuals qualified to service their own appliances can have...

Отзывы: