Specification Revised 11/99
R
Listed by
Underwriters
Laboratories
SCA2000BBB - GE Profile Performance
™
Advantium
™
Oven
Dimensional Information (in inches)
66" MIN.
Mounting
height
from
floor
30"
MIN.
width
required
Exhaust outlet
connects to
3-1/4" X 10" duct
16-3/32
20-1/2"
Door open
14-13/16
15-19/32
12"
MAX.
1.
A minimum of 30” between the cabinets is required for the installation. If the space
between the cabinets is than 30”, a Filler Panel Kit may be used to fill the gap between
the oven and the cabinets. Your Owner’s Manual contains the kit number for your model.
2.
Make sure the bottom edge of the cabinet that will be above the oven will be at least 66”
from the floor and 30” from the cooking surface.
3.
For easier access to change the hood and range lamps, the bottom of the oven should be
at least 2” above the range backsplash.
4.
If you are going to vent your oven to the outside, see exhaust duct
preparation instructions.
5. When installing the oven beneath smooth, flat cabinets, be careful to follow the
instructions on the top cabinet template for power cord clearance.
6.
For best installation results, we recommend a maximum cabinet depth of 12”.
Installation Information:
This information is not intended to be used for installing unit described.
Before installing, consult installation instructions packed with product/kit for current dimensional data.
For answers to your Monogram,
®
GE Profile Performance Series,
™
GE Profile
™
or GE appliance questions, call
GE Answer Center
®
service, 800.626.2000.
Electrical Requirements:
Product rating is 240/208 volts AC, 60 Hertz, 30 amps and 6.5 kilowatts. This
product must be connected to an individual properly grounded branch
circuit, protected by circuit breakers or time delay fuses. Wire size must
conform to the requirements of the National Electric Code or the prevailing
local code for kilowatt rating. The outlet box should be located in the cabinet
above the oven. The supply circuit and outlet box should be installed by a
qualified electrician and conform to all prevailing electrical codes. The wall
outlet receptacle recommended for this appliance is
NEMA#14-30R
and
accepts the four prong grounded plug of this appliance.
WARNING - PLEASE READ CAREFULLY.
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED TO AVOID
SEVERE OR FATAL SHOCK.
DO NOT UNDER ANY CIRCUMSTANCES, CUT, DEFORM, OR REMOVE ANY OF THE
PRONGS FROM THE POWER CORD. DO NOT USE WITH AN EXTENSION CORD.
Insure proper ground
exists before use.
NEMA 14-30R
Wall Receptacle
Installation Requirements: