– 36 –
TCO
TCO
Upper Heater TCO's (Thermal Cut Outs)
• Location - Attached to the Upper Heater
Assembly.
• Upper Heater Halogen TCO's are labeled UHH1
and UHH2 on the schematic.
• UHH1 is a safety thermostat that interrupts
power to Upper Heater Halogen 1 in the event of
excessive temperatures.
• UHH2 is a safety thermostat that interrupts
power to Upper Heater Halogen 2 in the event of
excessive temperatures.
• Both TCO's are normally closed.
• Both open at 320°F and are non-resettable.
Disassembly
To remove either UHH1 or UHH2 TCO:
1. Remove the Air Tunnel Cover.
(See
Air Tunnel Cover
.)
2. Remove the 3 Phillips-head screws that
attach the Air Tunnel Outlet to the oven.
(See
Air Tunnel Outlet
.)
3. Lift and position the Air Tunnel Outlet to the
right.
4. Disconnect the 2 wires from the TCO.
5. Remove the Phillips-head screw that attaches
the TCO to the heat shield.
Convection Heater TCO (Thermal Cut Out)
• Location
(See
Right Side View
.)
• Interrupts line voltage to the Convection Heater
in the event of excessive temperatures.
• Normally
closed.
• Opens 320°F, non-resettable
Convection Heater TCO removal:
1. Remove the Outer Cover. (See
Outer Cover
.)
2. Disconnect the 2 wire harnesses from the TCO.
3. Remove the 2 Phillips-head screw that holds the
TCO in place.
Right Side View
TCO
Oven TCO (Thermal Cut Out)
• Location - Inside the Air Tunnel Outlet.
• Automatically shuts off oven in case the cavity
overheats for any reason.
• If the Oven TCO opens, it will disable all oven
functions including the display.
• Normally
closed.
• Opens 320°F, non-resettable.