– 65 –
Introduction and Operation
The dual wattage 4 pass Calrod Heater serves both to heat the water during a wash cycle and to heat the air
during the dry cycle. Heat and air circulation are required for good dry performance. Air circulation is natural
FRQYHFWLRQZLWKDLUHQWHULQJWKURXJKWKH¿OOIXQQHOWKHQH[LWLQJWKURXJKWKHYHQW7KHUHDUHQRPRWRU·V
blowers or damper doors on the New 2015 GE Plastic Tub Dishwashers.
'XULQJGU\WKHKHDWHOHPHQWF\FOHVDIWHUDQLQLWLDOPLQXWHRQWLPHWRVHFRQGVRȺVHFRQGVRQIRU
minutes during a Normal cycle with no wash boost options selected. Boost wash options will change the
time needed due to hotter temperatures in rinse for options and cycle selected. The below table represents a
normal cycle with heated dry option only selected.
6SHFL¿FDWLRQV
The Calrod Heating element is rated at 120 VAC, 27 ohms, 6.5 amp
Dry System
Heat Element
Heater Supports
Heater Clip (on Main Conduit)
Gasket
Nut
Ground Bracket
Cross Brace
Main Conduit
4 Pass Heater Algorithm, Dry Cycle
Normal with Heated Dry
Time (minutes) Calrod Description
6
Calrod on
28
&DOURG3XOVHPLQXWHRQPLQXWHRȺ
14
&DOURGRȺ&RRO'RZQ
Normal with Temp Boost or Sani Selected
6
Calrod on
58
&DOURG3XOVHPLQXWHRQPLQXWHRȺ
Heated Dry Element Algorithm
Heater 120 VAC
Wet
Dry
Watts
793
625
+/- 5%
Ohms
16.4
23.2
+/- 5%
Amps
6.6
5.2
+/- 5%
Содержание ADT521PGJ Series
Страница 19: ... 19 Silverware Basket on Door Silverware Basket in Bottom Rack ...
Страница 46: ... 46 Diagnostics Strip circuit ...
Страница 63: ... 63 Diagnostics Drain Pump Strip Circuit ...
Страница 68: ... 68 Schematics GDF520J GDF610J ...
Страница 69: ... 69 GDT535J ...
Страница 70: ... 70 ADT521J GDF610J GDF620J GDT545J GDT625J GDT635J ...
Страница 72: ... 72 Upper Spray System 5 8 61 V Vent Parts 4 33 W Warranty 72 Water Level 4 45 ...