background image

Installation Guide

Arize Factor

www.gecurrent.com

© 2022 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the General Electric 

Company and are used under license. Information provided is subject to change without notice. All values are design or typical 

values when measured under laboratory conditions. 
HORT171-EU (Rev 03/31/22)  99008909

Electrical products must not be thrown out with domestic waste. They must be taken to 

a communal collecting point for environmentally friendly disposal in accordance with 

local regulations. Contact your local authorities or stockist for advice on recycling. The 

packaging material is recyclable. Dispose of the packaging in an environmentally friendly 

manner and make it available for the recyclable material collection-service.

Horticultural lighting. Not suitable for household illumination.

UK and EU company information for UKCA and CE procedure:

Current Lighting Limited, 3rd Floor, 1 Ashley Road, Altrincham, UK, WA14 2DT

Current Netherlands B.V., Programmeurstraat 6, 1033MT Amsterdam, Netherlands

For the latest install guides for your product go to:

https://www.gecurrent.com/eu-en/indoor-lighting/horticulture-led-grow-lights

[email protected]

Save These Instructions

Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

Содержание 99008909

Страница 1: ...a oraz informacje dotyczące bezpieczeństwa Należy się z nimi dokładnie zapoznać przed przystąpieniem do instalacji produktu PT As chamadas de atenção e as informações relativas à segurança encontram se na última página do guia de instalação Deve lê las atentamente antes de iniciara SV Varningar och säkerhetsföreskrifter finns på sista sidan i installationsanvisningen Läs informationen noggrant inn...

Страница 2: ... kg 5 72 lbs 2 319W GEHF HBRVW1 ML900 BRV 2 6 kg 5 72 lbs 2 316W GEHF MPKRW1 ML300 PKR 2 6 kg 5 72 lbs 4 5 or 6 104W GEHF MPKBW1 ML300 PKB 2 6 kg 5 72 lbs 4 5 or 6 104W GEHF MPKFW1 ML300 PKF 2 6 kg 5 72 lbs 4 5 or 6 106W GEHF MBRIW1 ML300 BRI 2 6 kg 5 72 lbs 4 5 or 6 106W GEHF MBRVW1 ML300 BRV 2 6 kg 5 72 lbs 4 5 or 6 106W GEHF EPKBW1 ML200 PKB 2 6 kg 5 72 lbs 5 6 7 or 8 82W Components Provided ML...

Страница 3: ...18 in Extension Cable 0 59 kg 1 3 lbs Universal Cable Mount Product Code Detailed Description Weight 93153270 457 mm 18 in universal cable 0 04 kg 0 09 lbs 93154044 610 mm 24 in universal cable 0 05 kg 0 11 lbs 93154043 914 mm 36 in universal cable 0 06 kg 0 13 lbs 93153281 1524 mm 60 in universal cable 0 1 kg 0 22 lbs Optional Interconnection cable see table below Dimming cable 914 mm UL and CE 9...

Страница 4: ... can be suspended on a support structure A or on cables as shown above B and C Attach wireform supports by pushing up into the slots on the underside of the lightbar Wireform supports Cross section view 4 Installation Guide Arize Factor 1 1 Suspended Mount Installation Steps 3 A B C 51mm 2 in ...

Страница 5: ...g free upright ensure hooks on both sides are correctly engaged Ensure first end of bracket hook is lined up with oval mounting hole of driver Repeat on opposite driver mounting hole Standard hanger bracket fits over a 41 mm Unistrut If not preassembled install bracket onto driver 2 1 Installation of Standard Hanger Bracket 5 Installation Guide Arize Factor 1 3 5 2 4 ...

Страница 6: ...th Offset Hanger SNAP Offset hanger used with the standard hanger bracket to clear the bottom of the 41 mm Unistrut Standard bracket Offset hanger 41 mm Unistrut 2 3 Installation with Universal Cables Wrap loop end of cable over structural member Insert hook through loop end Attach hooks to oval driver mounting holes Ensure hook gate is closed Loop Hook 6 Installation Guide Arize Factor 1 1 2 2 ...

Страница 7: ...ter cable Shorting cap Lightbar 1 ML 300 Electrical Connection 4 to 8 Lightbars only DC adapter cable 93118693 93067609 93067610 8 n 4 to 8 5 6 Shorting cap Optional inter connection cable Driver Driver 1 ATTENTION Before attempting to install units or maintenance ensure power is off RISK OF SAFETY AND PRODUCT DAMAGE DO NOT MAKE OR BREAK ELECTRICAL CONNECTION WHILE POWER IS APPLIED ...

Страница 8: ...assemble connectors turn locking ring 1 8 of a turn counter clockwise and separate connectors Connect other end of cable to the first lightbar or extension cable Be sure to tighten collar NOTE Use 900 mm or 1500 mm extension cables if driver and lightbar are more than 0 6 m apart CLICK Recommended secure lightbar cable Driver connections DC Output Dimming AC Input DC adapter cable 8 Installation G...

Страница 9: ... first bead should be no more than 20mm from input connector 20mm 9 Installation Guide Arize Factor 1 2 3 7 If you choose to use your own custom AC input connection use a Wieland RST20i3 green connector 96 031 4055 7 OR 96 031 4155 7 OR 96 031 0055 7 OR 96 031 1055 7 and plug into the male AC connector of the driver 3 3 4 Connecting Driver to AC Line NOTE To disassemble connectors insert and twist...

Страница 10: ... Driver N 3 Y REPEAT FOR ENTIRE CIRCUIT BALANCING OUT EACH PHASE 3 L3 L2 L1 Driver Driver G G G G G G L L L L L L N N N N N N 8 6 7 Lightbar 1 5 WARNING Ambient temperature surrounding each driver must be lower than 40 C WARNING RISK OF ELECTRIC SHOCK Turn power off before installation inspection cleaning or removal And follow appropriate lock out tag out safety procedure Remove cap from dimming c...

Страница 11: ...kan genbruges Bortskaffe emballagen på en miljøvenlig måde og gør det tilgængeligt for indsamlingstjenesten for genanvendeligt materiale FI VAROITUS SÄHKÖISKUN RISKI Katkaise virta ennen tarkastusta asennusta tai irrottamista Sähkökotelo on maadoitettava asianmukaisesti TULIPALOVAARA Noudata kaikkia IEC n ja paikallisia rakennusmääräyksiä Tulo lähtöliitäntöihin saa käyttää ainoastaan IEC hyväksytt...

Страница 12: ...imballaggio in modo ecologico e renderlo disponibile per il servizio di raccolta del materiale riciclabile LT ĮSPĖJIMAS ELEKTROS ŠOKO PAVOJUS Išjunkite maitinimą prieš apžiūrą montavimą arba šalinimą Tinkamai įžeminkite elektrinį gaubtą GAISRO PAVOJUS Vadovaukitės visais IEC ir vietiniais statybos kodeksais Įvesties išvesties jungtims naudokite tik IEC reikalavimus atitinkančius laidus Minimalus d...

Страница 13: ...mić WYSTĘPUJE ZAGROŻENIE POŻAROWE Należy przestrzegać wszystkich norm IEC oraz lokalnych przepisów budowlanych Do połączeń wejścia i wyjścia należy stosować wyłącznie przewody z atestem IEC Minimalna powierzchnia przekroju przewodów to 3G 0 75mm2 Lampa LED musi być podłączona do sieci zasilania o parametrach zgodnych z podanymi na tabliczce znamionowej produktu UWAGA Nie wolno użytkować produktu z...

Страница 14: ...rlı bir şekilde imha edin ve geri dönüştürülebilir malzeme toplama hizmeti için kullanılabilir hale getirin SV VARNING RISK FÖR ELEKTRISKA STÖTAR Stäng av före inspektion installation och borttagning Jorda den elektriska enheten korrekt BRANDRISK Följ alla relevanta IEC och lokala förordningar Använd enbart IEC godkända anslutningar Minimistorlek 3G 0 75mm2 LED Digital Controller måste anslutas ti...

Страница 15: ...our local authorities or stockist for advice on recycling The packaging material is recyclable Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection service Horticultural lighting Not suitable for household illumination UK and EU company information for UKCA and CE procedure Current Lighting Limited 3rd Floor 1 Ashley Road Altri...

Отзывы: