1.1.20 Mains Supply 3 x 380 - 480 VAC
Normal overload 150% for 1 minute
Frequency converter
Typical Shaft Output [kW]
0.37
0.75
1.5
2.2
3.0
4.0
Typical Shaft Output [HP]
0.5
1
2
3
4
5
IP 20
Unit Size
M1
Unit Size
M1
Unit Size
M2
Unit Size
M2
Unit Size
M3
Unit Size
M3
Output current
Continuous (3 x 380-440 V) [A]
1.2
2.2
3.7
5.3
7.2
9.0
Intermittent (3 x 380-440 V) [A]
1.8
3.3
5.6
8.0
10.8
13.7
Continuous (3 x 440-480 V) [A]
1.1
2.1
3.4
4.8
6.3
8.2
Intermittent (3 x 440-480 V) [A]
1.7
3.2
5.1
7.2
9.5
12.3
Max. cable size:
(mains, motor) [mm
2
/ AWG]
4/10
Max. input current
Continuous (3 x 380-440 V ) [A]
1.9
3.5
5.9
8.5
11.5
14.4
Intermittent (3 x 380-440 V ) [A]
2.6
4.7
8.7
12.6
16.8
20.2
Continuous (3 x 440-480 V ) [A]
1.7
3.0
5.1
7.3
9.9
12.4
Intermittent (3 x 440-480 V ) [A]
2.3
4.0
7.5
10.8
14.4
17.5
Max. mains fuses [A]
See Section
Fuses
Environment
Estimated power loss [W], Best case/
Typical
1)
18.5/
25.5
28.5/
43.5
41.5/
56.5
57.5/
81.5
75.0/
101.6
98.5/
133.5
Weight enclosure IP20 [kg]
1.1
1.1
1.6
1.6
3.0
3.0
Efficiency [%], Best case/
Typical
1)
96.8/
95.5
97.4/
96.0
98.0/
97.2
97.9/
97.1
98.0/
97.2
98.0/
97.3
Table 1.8: Mains supply 3 x 380 - 480 VAC
1.
At rated load conditions.
Normal overload 150% for 1 minute
Frequency converter
Typical Shaft Output [kW]
5.5
7.5
11
15
18.5
22
Typical Shaft Output [HP]
7.5
10
15
20
25
30
IP 20
Unit Size
M3
Unit Size
M3
Output current
Continuous (3 x 380-440 V) [A]
12.0
15.5
23.0
31.0
37.0
43.0
Intermittent (3 x 380-440 V) [A]
18.0
23.5
34.5
46.5
55.5
64.5
Continuous (3 x 440-480 V) [A]
11.0
14.0
21.0
27.0
34.0
40.0
Intermittent (3 x 440-480 V) [A]
16.5
21.3
31.5
40.5
51.0
60.0
Max. cable size:
(mains, motor) [mm
2
/ AWG]
4/10
16/6
Max. input current
Continuous (3 x 380-440 V ) [A]
19.2
24.8
33.0
42.0
34.7
41.2
Intermittent (3 x 380-440 V ) [A]
27.4
36.3
47.5
60.0
49.0
57.6
Continuous (3 x 440-480 V ) [A]
16.6
21.4
29.0
36.0
31.5
37.5
Intermittent (3 x 440-480 V ) [A]
23.6
30.1
41.0
52.0
44.0
53.0
Max. mains fuses [A]
See Section
Fuses
Environment
Estimated power loss [W], Best case/
Typical
1)
131.0/
166.8
175.0/
217.5
290.0/
342.0
387.0/
454.0
395.0/
428.0
467.0/
520.0
Weight enclosure IP20 [kg]
3.0
3.0
Efficiency [%], Best case/
Typical
1)
98.0/
97.5
98.0/
97.5
97.8/
97.4
97.7/
97.4
98.1/
98.0
98.1/
97.9
Table 1.9: Mains supply 3 x 380 - 480 VAC
1.
At rated load conditions.
AF-60 LP
™
Micro Drive
DEH-41264A
17
1