2
Dialog QS1500 Touchtalk Interactive Keypad Installation Instructions
• Key mode keypads should be programmed using sensor groups 01, 03, 06, or 07 for non
supervised use.
• Chime mode keypads can be programmed using sensor groups 01, 03, 06 or 07 for non
supervised use or sensor groups 00, 02, 04 or 05 for supervised use.
• The keypad must be deleted and reprogrammed into panel memory every time the key-
pad operating mode is changed.
• Each learned keypad uses one of the available sensor numbers (24 total sensors/zones
can be used with the Simon 3 panel).
• When the keypad is mounted on the wall, it might not work properly if mounted too
close to the Simon 3 panel.
Programming
For complete programming instructions, refer to your Simon 3 installation instructions. The
keypad must be programmed for key or chime mode before programming into panel mem-
ory.
¾
To program the keypad mode:
1. Remove the mounting plate on the back of the keypad.
2. Insert two of the three batteries into the keypad.
Note
To check the software ver-
sion of the keypad, press 1
after Step 3.
3. While holding down the
Lights On
and
Lights Off
keys, insert the third battery. Release
the keys. The keypad will sound one long beep.
4. Immediately
press 8
to program the keypad for key mode. The keypad announces “No
chime hello, touchpad OK”.
OR
Press 9
to program the keypad for chime mode. The
keypad announces “Chime hello, touchpad OK”.
Note
The “Chime” and “No chime” announcements from the keypad only describe the keypad mode
being programmed. The announcements don’t describe doors and special motion chime functions
programmed at the panel.
After programming the mode, the keypad must be programmed into the panel.
¾
To program the keypad into panel memory:
1. Open the control panel cover.
2. Enter Utility Access Code 1 or 2 using the red numbered keys.
3. Press
Add
. The panel announces “Select from Main Menu.”
4. Press
Sensor/Remote
. The panel announces “Press button on sensor.”
Note
If the keypad doesn’t
announce “OK”, press
Can-
cel
at the panel and repeat
process starting from Step 3.
5. Press the
Lights
Off
button on the keypad six times in rapid succession. On the sixth key
press the keypad makes a long beep. The keypad announces “OK”, to indicate that it has
been learned into the panel. Panel announces keychain remote.
Note
For a more specific location
name, press
Option #
for
compass directions (north,
northeast, east, southeast,
south, southwest, west,
northwest).
6. Press
Sensor/Remote
repeatedly until you hear the sensor name or item you want to use.
Each name may be used more than once.
7. Press
DONE
when you hear the desired sensor name. The panel announces “Use num-
bered keys to enter sensor group.”
Note
If you wish to use a sensor
number other than the next
one available, use the num-
bered keys to enter a 2 digit
sensor number immediately
after entering the sensor
group.
8. Enter the 2-digit sensor group (Key mode: 01, 03, 06 or 07 OR Chime mode: 00 through
07). The panel announces the sensor group and the first available sensor number, then
prompts you to press
DONE
to accept.
9. Press
DONE
. The panel confirms programming by announcing the sensor number,
name, and group.
Performing a Sensor Test
The keypad is sensitive to its orientation to the control panel. For that reason, it is recom-
mended that you test the keypad prior to mounting it on the wall.
The following steps describe the guidelines for testing sensors used in a Simon 3 system.
1. Make sure the panel is disarmed.
2. Open the panel cover.
3. Enter the appropriate access code.