Dialog QS1500 Touchtalk Interactive Keypad Installation Instructions

 

• Key mode keypads should be programmed using sensor groups 01, 03, 06, or 07 for non 

supervised use.

• Chime mode keypads can be programmed using sensor groups 01, 03, 06 or 07 for non 

supervised use or sensor groups 00, 02, 04 or 05 for supervised use.

• The keypad must be deleted and reprogrammed into panel memory every time the key-

pad operating mode is changed.

• Each learned keypad uses one of the available sensor numbers (24 total sensors/zones 

can be used with the Simon 3 panel).

• When the keypad is mounted on the wall, it might not work properly if mounted too 

close to the Simon 3 panel.

Programming

For complete programming instructions, refer to your Simon 3 installation instructions. The 

keypad must be programmed for key or chime mode before programming into panel mem-

ory. 

¾

To program the keypad mode:

1. Remove the mounting plate on the back of the keypad.
2. Insert two of the three batteries into the keypad.

Note 

To check the software ver-

sion of the keypad, press 1 

after Step 3.

3. While holding down the 

Lights On

 and 

Lights Off

 keys, insert the third battery. Release 

the keys. The keypad will sound one long beep.

4. Immediately 

press 8

 to program the keypad for key mode. The keypad announces “No 

chime hello, touchpad OK”. 

OR

 

Press 9

 to program the keypad for chime mode. The 

keypad announces “Chime hello, touchpad OK”.

Note  

The “Chime” and “No chime” announcements from the keypad only describe the keypad mode 

being programmed. The announcements don’t describe doors and special motion chime functions 

programmed at the panel.

After programming the mode, the keypad must be programmed into the panel.

¾

To program the keypad into panel memory:

1. Open the control panel cover.
2. Enter Utility Access Code 1 or 2 using the red numbered keys.
3. Press 

Add

. The panel announces “Select from Main Menu.”

4. Press

 Sensor/Remote

. The panel announces “Press button on sensor.” 

Note 

If the keypad doesn’t 

announce “OK”, press 

Can-

cel 

at the panel and repeat 

process starting from Step 3.

5. Press the 

Lights

 

Off

 button on the keypad six times in rapid succession. On the sixth key 

press the keypad makes a long beep. The keypad announces “OK”, to indicate that it has 

been learned into the panel. Panel announces keychain remote.

Note 

For a more specific location 

name, press 

Option #

 for 

compass directions (north, 

northeast, east, southeast, 

south, southwest, west, 

northwest).

6. Press 

Sensor/Remote

 repeatedly until you hear the sensor name or item you want to use. 

Each name may be used more than once.

7. Press 

DONE

 when you hear the desired sensor name. The panel announces “Use num-

bered keys to enter sensor group.”

Note 

If you wish to use a sensor 

number other than the next 

one available, use the num-

bered keys to enter a 2 digit 

sensor number immediately 

after entering the sensor 

group.

8. Enter the 2-digit sensor group (Key mode: 01, 03, 06 or 07 OR Chime mode: 00 through 

07). The panel announces the sensor group and the first available sensor number, then 

prompts you to press 

DONE

 to accept.

9. Press 

DONE

. The panel confirms programming by announcing the sensor number, 

name, and group.

Performing a Sensor Test

The keypad is sensitive to its orientation to the control panel. For that reason, it is recom-

mended that you test the keypad prior to mounting it on the wall. 
The following steps describe the guidelines for testing sensors used in a Simon 3 system.
1. Make sure the panel is disarmed.
2. Open the panel cover. 
3. Enter the appropriate access code.