background image

2

Brine Valve PN 3020511

Brine Well Installation

1. The brine well should be vertically installed in the 

regenerant tank. 

2. All connections should be manually tightened to 

ensure a solid connection. DO NOT over tighten plastic 
parts with a wrench, or you might damage plastic 
components.

3. Set the postion of the brine valve float. The float 

should be positioned 0.8" - 2" (20 - 50 mm) above the 
brine surface level or as required for application.

CAUTION: 

DO NOT use petroleum based lubricants such as 

vaseline, oils, or hydrocarbon based lubricants. Use only 
100% silicone lubricant.

Operation

The brine valve will work with the control valve to 
automatically control the water level in the brine tank.
Another unique feature of the brine valve is the ability to 
adjust the top support. The top bracket can be moved up 
or down by loosening the lock nut. Hand tighten the 
locknut.

Figure 2

Figure 3

Regenerant Tube

Base Plug

Valve Base

Disassembly 

Assembly

Regenerant Tube - 3/8"

1/2” Lock Nut

Adjust Bracket

Plastic Tube

Arrow Direction to Tighten

Содержание 3020511

Страница 1: ... is a protective device against overfilling the brine tank Product Features Positive automatic opening and closing of the valve by using vacuum or pressure Unique mechanical structure developed according to scientific principles providing the best reliability Highly expandable interface with replacement fittings to coordinate different uses of the control valve Adjustments are designed for ease of...

Страница 2: ...equired for application CAUTION DO NOT use petroleum based lubricants such as vaseline oils or hydrocarbon based lubricants Use only 100 silicone lubricant Operation The brine valve will work with the control valve to automatically control the water level in the brine tank Another unique feature of the brine valve is the ability to adjust the top support The top bracket can be moved up or down by ...

Страница 3: ...e valve Replace brine valve Excessive refill Seal leak or failure Check for debris on seal Replace the seal The float does not close off incoming water Float is restricted by the bracket Raise top bracket to allow more space for float movement Damaged brine valve Replace brine valve System uses less brine than the regnerate setting Air leak Inspect pipeline and repair leaks Regenerant tube is too ...

Страница 4: ...8 14 3 8 inch Elbow 3 Regenerant tube 15 Pole base 4 Air check seal 16 Check ball 5 Float 17 Plastic pole 6 Rubber stop 18 Inner air check seal 7 Valve base 19 Inner connector 8 Base plug 20 Inner check ball enclosure 9 3 8 inch Retainer sleeve 21 Inner tube support 10 3 8 inch Plastic gripper 22 Fastener ring 11 3 8 inch Nut 23 Inner check seal retainer 12 Support bracket 11 10 9 ...