– 16 –
Advance Planning
These ovens may be installed directly into a 30”
•
wide oven cabinet.
Cutout dimensions are NOT the same for
•
installation with or without an accessory
storage drawer. Make sure to use the correct
cutout when preparing the opening.
Note:
Model ZSC2202 CANNOT be installed with
an accessory storage drawer. Refer to Installation
Instructions, Pub. 49-40574-1.
IMPORTANT
―
This oven is not approved for use
above another built-in Advantium Speedcook oven,
a side by side installation or below a countertop.
For personal safety, this oven cannot be
•
installed in a cabinet arrangement such as an
island or peninsula.
The oven must be installed at least 36-3/4"
•
above the
fl
oor.
Allow for clearance to adjacent corners, walls,
•
drawers, etc.
Cabinets installed adjacent to wall ovens
•
must have an adhesion spec of at least 194ºF
temperature rating.
The oven must be securely installed in a cabinet
•
that is
fi
rmly attached to the house structure.
Weight on the oven door could cause the oven
to tip and result in injury. Never allow anyone to
climb, sit, stand or hang on the oven door.
If installing the drawer accessory, the drawer
•
must be assembled to the oven prior to
installation into the cabinet. Refer to Installation
Instructions, Pub. 49-40574-1.
Electrical Requirements
Single Speedcook Installation
Product rating is 120/208 or 120/240 volt, 60 Hz,
30 amps. This product must be connected to a
supply circuit of the proper voltage and frequency
and protected by a time delay fuse or circuit
breaker. Power should be supplied from a separate,
dedicated 30-ampere branch circuit.
Installation
Wire size must conform to the requirements of the
National Electrical Code or the prevailing local code.
Combined Speedcook and Wall Oven Installation
When installed in combination with a GE/Monogram
single wall oven, use separate electrical junction
boxes.
Refer to single oven installation instructions for
electrical requirements of that product.
These connections must be made by a quali
fi
ed
electrician. All electrical connections must meet
National Electrical Code or prevailing local codes.
Combined Speedcook and Warming Drawer
Installation
When installing the Speedcook oven over a GE or
Monogram electric warming drawer, a separate
120V, 60Hz, properly grounded receptacle must be
installed. See instructions packed with the warming
drawer.
WARNING
The electrical power to the oven branch circuit
•
must be shut off while line connections are
being made.
Use copper wiring only.
•
Electrical ground is required on this appliance.
•
The free end of the green wire (ground wire)
must be connected to a suitable ground. This
wire must remain grounded to the oven.
If cold water pipe is interrupted by plastic, non-
•
metallic gaskets, union connections or other
insulating materials, DO NOT use for grounding.
DO NOT ground to a gas pipe.
•
DO NOT have a fuse in the NEUTRAL or
•
ROUNDING circuit. A fuse in the NEUTRAL or
ROUNDING circuit could result in an electrical
shock.
Check with a quali
fi
ed electrician if you are in
•
doubt as to whether the appliance is properly
grounded.
Failure to follow these instructions could result in
serious injury or death.