Step 5:  Activate Timer

1.  Turn the mechanism dial counter 

clockwise to set the current time as 
accurately as possible.

2.  After wiring and setting the timer 

with the ON/OFF trippers in the 
correct timer positions. Be sure to 
depress the ON or OFF lever to set 
the timer to the desired state. The 
timer will turn ON or OFF at the next 
programmed time.

3.  You cannot see the dial turning. 

Wait at least 30 minutes after the 
set ON or OFF time to verify the 
timer is operating properly.

Step 6:  Check timer after 24 hours

1.  After 24 Hours, remove power from the timer and check the connections:
  a. Remove plastic guard
  b. Verify all screws and connections are still firmly tightened.
  c. It is possible that after your initial tightening, the wire has compressed and 

loosened the connections. 

2.  After making sure everything is still tight, replace the plastic guard and 

restore power to the timer.

*Please review “Operating Instructions” in the user manual.

Содержание 15164

Страница 1: ...5 lbf in Use correct gauge wire 8 14 AWG based on local electrical code of at least 105C rating Approved for outdoor use Wire strip length GROUNDING National Electrical Code requires that grounding mu...

Страница 2: ...the pictures below to remove knockouts For knockout place small blade screw driver as pictured above Tap lightly to punch knockout loose For knockout first use screwdriver to punchout knockout then u...

Страница 3: ...face 3 If mounting to drywall a Drill a 3 16 size hole for the drywall anchors at the marked locations b Insert an anchor in each hole gently tap the open end of anchor with a hammer until the anchor...

Страница 4: ...before servicing Risk of electric shock All terminals are live Use copper wire only Close the cover after setting Tighten connections to 25 lbf in Use correct gauge wire 8 14 AWG based on local elect...

Страница 5: ...tic guard and also keep to the side Step 2 Connect the Input Clock Motor Voltage 1 Connect 240VAC Line 1 Black input to Terminal L 2 Connect 240VAC Line 2 Black input to Terminal 1 3 Connect the bare...

Страница 6: ...nnect 240VAC Line 2 Black of Load to Terminal 1 3 Connect the bare wire to the ground lug Tighten the screw terminals to 25in lb Improper tightening can cause heating and equipment failure Step 4 Rein...

Страница 7: ...dial turning Wait at least 30 minutes after the set ON or OFF time to verify the timer is operating properly Step 6 Check timer after 24 hours 1 After 24 Hours remove power from the timer and check t...

Страница 8: ...side connections It snaps easily in and out of place If the guard has come off during shipment or installation reinstall by placing the two tabs at the bottom in the appropriate slots 15164 VERSION 1...

Отзывы: