GE 10000 Скачать руководство пользователя страница 4

1  |  GE Oil & Gas

© 2015 General Electric Company. All rights reserved.

Safety Information

Important - Please Read Before Installation

Masoneilan 10000 Series Control Valve instructions contain 

DANGER, WARNING, and CAUTION labels, where necessary, 

to alert you to safety related or other important information. 

Read the instructions carefully before installing and maintaining 

your control valve. DANGER and WARNING  hazards are 

related to personal injury. CAUTION hazards involve equipment 

or property damage. Operation of damaged equipment can, 

under certain operational conditions, result in degraded process 

system performance that can lead to injury or death. Total 

compliance with all DANGER,  WARNING,  and  CAUTION 

notices is required for safe operation.

 

This is the safety alert symbol. It alerts you to potential 

 

personal injury hazards. Obey all safety messages that 

 

follow this symbol to avoid possible injury or death.

 

Indicates a potentially hazardous situation which, if not avoided, 
could result in death or serious injury.

 

Indicates a potentially hazardous situation which, if not avoided, 
could result in serious injury.

 

Indicates a potentially hazardous situation which, if not avoided, 
could result in minor or moderate injury.

 

When used without the safety alert symbol indicates a 

 

potentially hazardous situation which, if not avoided, could result 
in property damage.

Note: Indicates important facts and conditions.

About this Manual

•  The information in this manual is subject to change without prior 

notice.

•  The information contained in this manual, in whole or part, shall 

not be transcribed or copied without GE’s written permission.

•  Please report any errors or questions about the information in 

this manual to your local supplier.

•  These  instructions  are  written  specifically  for  the  10000 Series 

Control Valve, and do not apply for other valves outside of this 
product line.

Life Period

The current estimated useful life period for the Masoneilan 10000 
Series control valve is 25+ years. To maximize the useful life of 
the product it is essential to conduct annual inspections, routine 
maintenance and ensure proper installation to avoid any unintended 
stresses on the product.  The specific operating conditions will also 
impact the useful life of the product. Consult the factory for guidance 
on specific applications if required prior to installation.

Warranty

Items sold by General Electric are warranted to be free from 
defects in materials and workmanship for a period of one year 
from the date of shipment provided said items are used according 
to GE recommended usages. GE reserves the right to discontinue 
manufacture of any product or change product materials, design 
or specifications without notice.

This instruction manual applies to the Masoneilan 10000 Series 
Control Valve.

The Control Valve and Actuator:

•  MUST  BE  installed,  put  into  service  and  maintained  by 

qualified and competent professionals who have undergone  
suitable training.

•  Under  certain  operating  conditions,  the  use  of  damaged 

equipment could cause a degradation of the performance of 
the system which may lead to personal injury or death.

•  Changes  to  specifications,  structure,  and  components  used 

may not lead to the revision of this manual unless such 
changes affect the function and performance of the product.

•  All air supply to the actuator must be turned off.

•  All  surrounding  pipe  lines  must  be  thoroughly  flushed  

to ensure all entrained debris has been removed from 

 

the system.

Содержание 10000

Страница 1: ...GE Oil Gas 10000 Series Masoneilan Double Ported Globe Valve Instruction Manual GE Data Classification Public...

Страница 2: ...E SITE AND THE PARTICULAR REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE...

Страница 3: ...s Page 1 Introduction 2 2 Unpacking 2 3 Installation 2 4 Air Piping 2 5 Body Disassembly Refer to Figure 9 3 6 Maintenance Repair 3 6 1 Seat Ring Removal 3 6 2 Bushing Removal 3 6 3 Lapping Seats 3 6...

Страница 4: ...Please report any errors or questions about the information in this manual to your local supplier These instructions are written specifically for the 10000 Series Control Valve and do not apply for ot...

Страница 5: ...o that the larger of the two V notches in the plug is oriented to face the inlet of the valve 3 1 Before installing the valve in the line clean piping and valve of all foreign materials such as weldin...

Страница 6: ...g Removal Threaded seat rings 15 and 16 are installed tightly at the point of manufacture and after years of service they are often difficult to remove To facilitate removal seat ring wrenches can be...

Страница 7: ...ce bonnet 6 on the body and using body stud nuts 12 spaced equally apart fasten to the body using only slight pressure and tighten evenly Do not tighten nuts to torque specifications at this time The...

Страница 8: ...his could prevent smooth operations of the valve If all compression is used up and the valve leaks new packing is required Valve must be isolated and pressure vented before performing packing box main...

Страница 9: ...f the two V notches in that plug is in line with the inlet of the valve Placement of a witness mark on the stem may be helpful E Install bonnet gasket 13 bonnet 6 and loosely install body stud nuts 11...

Страница 10: ...ure 10 Ref No Description 1 Plug Stem 2 Packing Flange Nut 3 Packing Flange 4 Packing Flange Stud 5 Drive Nut 6 Valve Bonnet 7 Valve Body 8 Plug Pin 9 Plug 10 Lower Flange 11 Body Stud Nut 12 Body Stu...

Страница 11: ...Masoneilan 10000 Series Globe Valve Instruction Manual 8 2015 General Electric Company All rights reserved Notes...

Страница 12: ...tered trademarks or trademarks of their respective owners General Electric Company All rights reserved Visit our web site www fr eps com E P S FRANCE 24 bis rue de Picpus 75012 PARIS Tel 33 0 9 83 01...

Отзывы: