Philips ProBridge 15 0150-0241B
RS485 Network Address
Camera Address
AutoDome Address
025
1 – 32
0769 – 0800
026
1 – 32
0801 – 0832
027
1 – 32
0833 – 0864
028
1 – 32
0865 – 0896
029
1 – 32
0897 – 0928
030
1 – 32
0929 – 0960
031
1 – 32
0961 – 0992
032
1 – 32
0993 – 1024
--
--
--
255
1 – 32
8129 – 8160
Philips AutoDome Addresses are calculated as follows:
Philips AutoDome Address = Camera A 32 X (Network Address – 1)
Philips Data Converter Unit Switch Setting
Set the switches on the LTC8780 as follows:
S101:
Switches 1, 3, and 4 set to
OFF
. Switch 2 set to
ON
.
S102:
Switches 1 –3 set on
ON
, switch 4 set to
OFF
.
See Philips LTC8780 manual for details.
6.3 Using Kalatel Keypads
Keyboards (CBR-KB3/J and KTD-405) are typically used to provide initial
configuration of the Philips AutoDome for setting addresses and presets.
In some specific cases keyboards may be used in conjunction with
the CBR-PB2-PHILIPS units where multiple Kalatel units are being
controlled via one or more local Keyboard. Available keyboards
are only involved when an RS-485 is configured with CBR-KB2/J,
CBR-KB3/J and KTD-405 Keyboards. Please contact Technical
Support for additional instructions concerning these special
installations.