GE Wiring Devices & Specialty Products GE5805WS6 Скачать руководство пользователя страница 3

3

GB

A.

A.

A.

A.

A. TW

TW

TW

TW

TWO-LINE DISPLA

O-LINE DISPLA

O-LINE DISPLA

O-LINE DISPLA

O-LINE DISPLAY

Y

Y

Y

Y

Facilitates easy reading of outdoor temperature and humidity.

B.

B.

B.

B.

B. LED INDICA

LED INDICA

LED INDICA

LED INDICA

LED INDICAT

T

T

T

TOR

OR

OR

OR

OR

Flashes when the remote unit transmits a reading

C.

C.

C.

C.

C. CHANNEL SLIDE SWITCH

CHANNEL SLIDE SWITCH

CHANNEL SLIDE SWITCH

CHANNEL SLIDE SWITCH

CHANNEL SLIDE SWITCH
Designates the remote unit Channel 1, Channel 2 or Channel 3

D.

D.

D.

D.

D. °C/°F SLIDE SWITCH

°C/°F SLIDE SWITCH

°C/°F SLIDE SWITCH

°C/°F SLIDE SWITCH

°C/°F SLIDE SWITCH
Selects between degree Centigrade (°C) and Fahrenheit (°F)

E.

E.

E.

E.

E. RESET B

RESET B

RESET B

RESET B

RESET BUTT

UTT

UTT

UTT

UTTON

ON

ON

ON

ON

Returns all settings to default values

F.

F.

F.

F.

F. B

B

B

B

BA

A

A

A

ATTER

TTER

TTER

TTER

TTERY COMP

Y COMP

Y COMP

Y COMP

Y COMPAR

AR

AR

AR

ARTMENT

TMENT

TMENT

TMENT

TMENT

Accommodates two AA-size batteries

G.

G.

G.

G.

G. B

B

B

B

BA

A

A

A

ATTER

TTER

TTER

TTER

TTERY DOOR

Y DOOR

Y DOOR

Y DOOR

Y DOOR

H

H

H

H

H..... W

W

W

W

WALL-MOUNT RECESSED HOLE

ALL-MOUNT RECESSED HOLE

ALL-MOUNT RECESSED HOLE

ALL-MOUNT RECESSED HOLE

ALL-MOUNT RECESSED HOLE

For mounting the remote unit on a wall

BEFORE 

BEFORE 

BEFORE 

BEFORE 

BEFORE Y

Y

Y

Y

YOU BEGIN

OU BEGIN

OU BEGIN

OU BEGIN

OU BEGIN

For best operation,

1. Assign different channels to different remote units.

2. Insert batteries for remote units before doing so for the main

unit.

3. Place the main unit as close as possible next to the remote unit,

reset the main unit after installing batteries. This will ensure
easier synchronization between the transmission and reception
of signals.

4. Position the remote unit and main unit within effective

transmission range, which, in usual circumstances, is 20 to 30
meters.

Note that the effective range is vastly affected by the building
materials and where the main and remote units are positioned. Try
various set-ups for best result.

Though the remote units are weather proof, they should be placed
away from direct sunlight, rain or snow.

B

B

B

B

BA

A

A

A

ATTER

TTER

TTER

TTER

TTERY 

Y AND CHANNEL

AND CHANNEL

AND CHANNEL

AND CHANNEL

AND CHANNEL

INST

INST

INST

INST

INSTALLA

ALLA

ALLA

ALLA

ALLATION:

TION:

TION:

TION:

TION: REMO

 REMO

 REMO

 REMO

 REMOTE UNIT

TE UNIT

TE UNIT

TE UNIT

TE UNIT

1. Remove the screws on the battery compartment.

2. Select the channel number on the CHANNEL slide switch.

3. Select °C or °F with the °C/°F slide switch.

4. Install 2     alkaline     batteries (UM-3 or “AA” size 1.5V) strictly

according to the polarities shown.

5. Replace the battery compartment door and secure its screws.

Note that once a channel is assigned to a remote unit, you can only
change it by removing the batteries or resetting the unit.

RAR286HG-e.p65

2003/11/5, AM 10:51

3

Содержание GE5805WS6

Страница 1: ...ur purchase of the GE5805WS6 Multi Chan nel In Out Thermo Hygrometer with 433MHz cable free sensor and calendar clock The basic package comes with a main unit which is the temperature humidity and calendar clock station and a remote unit the thermo hygro sensor The main unit has large read outs for In Out temperature and humidity which are collected and transmitted by the remote unit The main unit...

Страница 2: ...TT UTT UTT UTT UTTON ON ON ON ON Toggles the display modes and set the time for calendar clock C C C C C MEM B MEM B MEM B MEM B MEM BUTT UTT UTT UTT UTTON ON ON ON ON Recalls the maximum or minimum temperature of individual channels D D D D D CH B CH B CH B CH B CH BUTT UTT UTT UTT UTTON ON ON ON ON Selects among different channels E E E E E AL B AL B AL B AL B AL BUTT UTT UTT UTT UTTON ON ON ON ...

Страница 3: ...IN OU BEGIN For best operation 1 Assign different channels to different remote units 2 Insert batteries for remote units before doing so for the main unit 3 Place the main unit as close as possible next to the remote unit reset the main unit after installing batteries This will ensure easier synchronization between the transmission and reception of signals 4 Position the remote unit and main unit ...

Страница 4: ...unt B B B B BA A A A ATTER TTER TTER TTER TTERY INST Y INST Y INST Y INST Y INSTALLA ALLA ALLA ALLA ALLATION TION TION TION TION MAIN UNIT MAIN UNIT MAIN UNIT MAIN UNIT MAIN UNIT 1 Open the battery compartment door 2 Install 2 alkaline batteries UM 3 or AA size 1 5V strictly according to the polarities shown 3 Replace the battery compartment door LO LO LO LO LOW B W B W B W B W BA A A A ATTER TTER...

Страница 5: ...HOW W W W W T T T T TO CHECK REMO O CHECK REMO O CHECK REMO O CHECK REMO O CHECK REMOTE REMO TE REMO TE REMO TE REMO TE REMOTE TE TE TE TE AND AND AND AND AND INDOOR READINGS INDOOR READINGS INDOOR READINGS INDOOR READINGS INDOOR READINGS The indoor temperature and humidity are shown on the bottom line of the display As for the remote sites or channels press CH CH CH CH CH to go from one chan nel ...

Страница 6: ... AND F AND F AND F AND F AND F The unit of temperature display is selected on the C F slide switch Select C for Centigrade or F for Fahrenheit HO HO HO HO HOW W W W W T T T T TO READ O READ O READ O READ O READ THE KINETIC THE KINETIC THE KINETIC THE KINETIC THE KINETIC W W W W WA A A A AVE VE VE VE VE DISPLA DISPLA DISPLA DISPLA DISPLAY Y Y Y Y The kinetic wave display shows the signal receiving ...

Страница 7: ...kday For display language you can choose among English E Ger man D French F Italian I and Spanish S in that order Day of week is the usual sequence of Monday through Sunday If there is an item you do not wish to change simply press MODE MODE MODE MODE MODE to bypass the item When you are done press MODE MODE MODE MODE MODE to exit The display will return to the mode last chosen HO HO HO HO HOW W W...

Страница 8: ...e day driven in this mode You can go back in time or travel to the future any day between 2000 to 2099 The correcponding moon phase will appear immediately on the screen The unit will return to the last display mode when the UP UP UP UP UP and DO DO DO DO DOWN WN WN WN WN buttons are left idle for 10 seconds PRECA PRECA PRECA PRECA PRECAUTIONS UTIONS UTIONS UTIONS UTIONS This product is engineered...

Страница 9: ...ndar Clock k k k k 12 h display with hh mm ss Date Format Month Day Day of week selectable in 5 language E F D I S 2 minute single alarm Moon Phase Function Moon Phase Function Moon Phase Function Moon Phase Function Moon Phase Function Moon Phase scanner Range From 2000 to 2099 P P P P Po o o o ow w w w wer er er er er Main unit use 2 pcs UM 3 or AA 1 5V battery Remote sensing unit use 2 pcs UM 3...

Страница 10: ...into an outlet on a circuit different from that to which the receiver is connected Consult the dealer of an experienced radio TV technician for help Compan Compan Compan Compan Company Name y Name y Name y Name y Name GE Wiring Devices Specialty Products Inc d b a GE Home Electric Products Inc Ad Ad Ad Ad Addr dr dr dr dress ess ess ess ess 1975 Noble Rd Cleveland OH 44112 USA Contact P Contact P ...

Отзывы: