SuperBus 2000 900MHZ RF Transceiver Module Installation Instructions

Preliminary 3/1/04

Installation

Installation Guidelines

Observe the following guidelines when installing the transceiver module:

Concord

 systems can accommodate a maximum of 96 wireless sensors/zones.

In Concord systems, up to 16 SuperBus 2000 devices can be connected to the panel 
(SuperBus 2000 Touchpads, Receivers, Transceivers, HIMs, HOMs, ESMs, etc.). 

Each bus device must have a different unit number.

Leave 4 inches above the module for the antenna.

When mounting the module away from the panel, use the wire length guidelines in 
Table 2.

Avoid areas that are likely to expose the module to moisture.

Avoid areas with excessive metal or electrical wiring, including furnace and utility 
rooms. If unavoidable, mount on or near metal with the antenna extending above the 
metallic surfaces, as shown in Figure 2.

Figure 2. Mounting on or Near Metal

Tools and Supplies

Screwdrivers

Drill with bits

Mounting screws and anchors (included)

4-conductor, 22-gauge or larger, stranded wire

Support standoff (included with Concord cabinet)

¼-inch press-fit reed switch and magnet (not included)

Small hammer

Mounting the Transceiver

The module can be mounted on any interior wall (protected from the elements).

SuperBus 2000 Device ID Number Label

Identifies unique module SuperBus 2000 
device ID number (SuperBus 2000 panels).

Transceiver Status LED

On continuously when the transceiver is 
powered. Flashes when an RF signal is 
received.

Terminal Strip

Used for power and bus connections to panel.

Table 1: Component Descriptions

Component

Function

Table 2: Maximum Module Wire Lengths

Wire Gauge (Unshielded or 

Shielded)

Max. Wire Length Between Module and Concord 

Panel

18

2,800 feet

22

1,100 feet

METAL

METAL