background image

P/N 1069681 • REV 1.0 • ISS 14APR10 

7 of 11 

Control Room Installation 

UTP: 

•  Connect the UTP wires carrying video signals to the terminal block input of 

the receiver hub. If the UTP is terminated with a RJ-45 connector, then use 
either the RJ-45 connector or provided RJ-45 adapter to connect to the 
transceiver hub. 

•  Make sure that the same UTP pair and polarity are used on both transmit 

and receive sides. 

 

Video: 

•  Use provided 2-foot (60 cm) coax patch cords to connect the BNC video 

inputs of video receiving devices such as DVRs or matrix switches. 

Power: 

GEC-4VARHUB-4  

•  Connect the ground screw connector to a qualified earth ground using a 

short thick wire.  

•  Connect the external power supply cable to the power input connector of the

 

GEC-4VARHUB-4

.  

Note: 

This product is intended to be supplied by a UL Listed Direct Plug-In Power 

Unit marked “Class 2” or “LPS” and output rated 12 VDC, 1 Amp minimum. 

All other models   

•  Connect the AC power cord to a grounded AC power outlet.  

•  The receiver hubs do not require any adjustments. They are equipped with 

Automatic Video Compensation (AVC) circuit that automatically adjusts the 
video quality regardless of video content.  

Содержание GEC-16VARHUB-4

Страница 1: ...any GE Passive Transceiver for distances up to 3 500 feet 1 067 m The 8 channel models provide 1 to 4 distribution amplifiers while the 16 channel models include 1 to 2 distribution amplifiers These receiver hubs are 1U in height and can be wall desk or rack mounted Their integrated ground loop isolation prevents disturbing hum bars common with long distance installations Their excellent crosstalk...

Страница 2: ...ing No objects filled with liquids such as vases shall be placed on GE equipment DO NOT block ventilation openings to let sufficient airflow to the UTP devices The Main fuse for models with built in AC power supply is 5 A at 110 VAC or at 3 A 220 VAC Each camera power fuse is 2 A and can be accessed by removing the front panel Fuses may be replaced by a qualified service person only when the unit ...

Страница 3: ...as been damaged in any way such as a power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture This apparatus shall not be exposed to dripping or splashing ...

Страница 4: ...ivers Passive GE transceivers can transmit video and Up the Coax P T Z control signals up to 750 ft 228 m We recommend using short 18 AWG solid wires for ground connections GE VPD products follow the EIA TIA 568 standard There are two wire color code standards EIA TIA 568A and EIA TIA 568B Either standard can be used for making connections as long as the RJ 45 jacks at both ends of each cable foll...

Страница 5: ...e Camera 10 8 VDC 21 6 VAC 21 6 VAC Dual 24 AWG 448 ft 137 m 896 ft 273 m 2 388 ft 728 m 100 mA Camera Dual 23 AWG 564 ft 172 m 1 130 ft 345 m 3 012 ft 918 m Dual 24 AWG 150 ft 46 m 300 ft 92 m 796 ft 243 m 300 mA Camera Dual 23 AWG 190 ft 58 m 378 ft 115 m 1 004 ft 306 m Dual 24 AWG 46 ft 14 m 90 ft 28 m 240 ft 73 m 1 AMP Camera Dual 23 AWG 58 ft 18 m 114 ft 35 m 300 ft 92 m Application Drawings ...

Страница 6: ...e GEC PVTC FCSP GEC PVTC MSP Connect the UTP to the terminal block of the GE transceiver Active Transmitter Connect the baseband video output of the camera to the BNC input of the GE active transmitter Connect the UTP to the terminal block of transmitter Connect the ground screw connector to a qualified earth ground using a short thick wire Set the distance switch to the appropriate position based...

Страница 7: ...o inputs of video receiving devices such as DVRs or matrix switches Power GEC 4VARHUB 4 Connect the ground screw connector to a qualified earth ground using a short thick wire Connect the external power supply cable to the power input connector of the GEC 4VARHUB 4 Note This product is intended to be supplied by a UL Listed Direct Plug In Power Unit marked Class 2 or LPS and output rated 12 VDC 1 ...

Страница 8: ...nt Green LED s one per channel Power indicator Red LED Connectors UTP inputs Detachable terminal blocks RJ 45 or Optional RJ 45 Adapter Included Video Outputs BNC Power IEC380 AC power inlet excluding GEC 4VARHUB 4 Standard P1J DC inlet receptacle 2 1 x 5 5 mm center positive GEC 4VARHUB 4 Main AC Fuse 1 A at 115 VAC 3 A at 220 VAC 5x20 mm 8 channel models 1 5 A at 115 VAC 5 A at 220 VAC 5x20 mm 1...

Страница 9: ...ct Plug In Power Unit marked Class 2 or LPS and output rated 12 VDC 1 Amp minimum Mechanical Material GEC 4VARHUB 4 ABS plastic UL rating of 94V 0 All other models Extruded Aluminum and sheet metal Dimensions W x H x D GEC 4VARHUB 4 4 97 x 1 74 x 1 77 in 12 6 x 4 2 x 4 5 cm GEC 8VARHUB 4 17 x 1 74 x 8 in 43 x 4 2 x 203 cm GEC 16VARHUB 4 17 x 1 74 x 8 in 43 x 4 2 x 203 cm GEC 32VARHUB 4 17 x 1 74 x...

Страница 10: ... Accessories Excluding the GEC 4VARHUB 4 Mounting brackets for front rear or wall installations Rubber feet for desk applications 8 16 or 32 2 ft 60 cm coax jumper cables RJ 45 Adapter Molded IEC power inlet cord 7 ft 200 cm EIA TIA 568A B Color Codes ...

Страница 11: ... there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation betwee...