GE Profile HE Dryer
(3/3/08)
GE CONFIDENTIAL & PROPREITARY INFORMATION - NOT FOR PUBLIC DISCLOSURE
Copyright 2008 General Electric Company
15
g
GE imagination at work
Test 7
•
Heater 1 and heater 2 Test
•
The display will initially show “t7”.
•
Once the start button is pushed, turn on
heater
1 and heater 2
together. The display shall show
the value of the outlet thermistor from 00 to 137,
which is considered a valid range. If the value
from thermistor is outside of the range; there is
an error in the outlet thermistor and control
should display “tE”. If the display shows a value
and doesn’t change the value, there is a heater
1 or heater 2 error.