manualshive.com logo in svg
background image

GE Profile HE Dryer 

(3/3/08)

GE CONFIDENTIAL & PROPREITARY INFORMATION - NOT FOR PUBLIC DISCLOSURE
Copyright 2008 General Electric Company

1

g

GE imagination at work

GE Profile HE Dryer 

DPGT650E/G

Содержание DPGT650E

Страница 1: ...GE Profile HE Dryer 3 3 08 GE CONFIDENTIAL PROPREITARY INFORMATION NOT FOR PUBLIC DISCLOSURE Copyright 2008 General Electric Company 1 gGE imagination at work GE Profile HE Dryer DPGT650E G ...

Страница 2: ...ROPREITARY INFORMATION NOT FOR PUBLIC DISCLOSURE Copyright 2008 General Electric Company 2 gGE imagination at work Control Lock To lock and unlock control Press Dry level and Temp for 3 seconds Replacement control may be shipped in locked mode cl ...

Страница 3: ...Company 3 gGE imagination at work Service Mode To Enter Service Mode In idle state No display on SSD Press and hold Less Time Wrinkle Care then press Power button to enter service mode If control does not display t1 the press and hold sequence was not executed correctly Press POWER to clear display then re enter Service Mode ...

Страница 4: ...OPREITARY INFORMATION NOT FOR PUBLIC DISCLOSURE Copyright 2008 General Electric Company 4 gGE imagination at work To Enter Service Mode Press and Hold Less Time and Wrinkle Care first Next press Power to enter Service mode Display will show t1 t1 ...

Страница 5: ...FOR PUBLIC DISCLOSURE Copyright 2008 General Electric Company 5 gGE imagination at work Press the Cycles Button to Navigate from Test to Test This also exits an existing Test Press the Start Button to enter enable a Test and to navigate from subtest to subtest Service Mode ...

Страница 6: ...R PUBLIC DISCLOSURE Copyright 2008 General Electric Company 6 gGE imagination at work Service Mode T1 LED Check T2 Software Revision T3 Motor Test T4 Door Switch Test T5 Humidity Sensor Test T6 Heater 1 and Outlet Thermistor Test T7 Heater 1 and Heater 2 Test T8 Error Codes ...

Страница 7: ...yer 3 3 08 GE CONFIDENTIAL PROPREITARY INFORMATION NOT FOR PUBLIC DISCLOSURE Copyright 2008 General Electric Company 7 gGE imagination at work tE Thermistor Outlet Error dE Door Switch Error EE EEPROM Error Error Codes ...

Страница 8: ...ON NOT FOR PUBLIC DISCLOSURE Copyright 2008 General Electric Company 8 gGE imagination at work Exit Service Mode To Exit Service Mode Press the Power Button If no key is pressed for 15 minutes the control will automatically exit Service Mode and enter the Idle State ...

Страница 9: ... General Electric Company 9 gGE imagination at work T1 Test Test 1 LED Component Check The display will initially show t1 Once the start button is pressed the Display shall initially toggle between t1 and H3 All LED s turn ON This cycle will continue until the Start button is pressed again All LED s turn off ...

Страница 10: ...he display will initially show t2 Once the start button is pushed the Display shall initially toggle between the product type EL or gA and the current revision of the software on unit Example EL then 01 Also the button operation can be checked while in this Test Press different button in Test control will turn on corresponding LED The display shall show this until the Start button is pressed ...

Страница 11: ... Electric Company 11 gGE imagination at work T3 Test Test 3 Dryer Motor Test The display will initially show t3 If dE door switch error is displayed or Door is open motor will not run Once the start button is pressed the Display will show 00 and tumble the drum The drum will tumble until the Start button is pressed ...

Страница 12: ...t work T4 Test Test 4 Door Switch Test The display will initially show t4 Once the start button is pushed the Display shall show dE if the door is open or 00 if the door is closed The display will automatically update with dE or 00 depending on the status of the door while this test is enabled The display will show this until the Start button is pressed ...

Страница 13: ... Once the start button is pressed the display will show a value from 30 very damp to 255 very dry depending on that state of the clothing that is being touched to the sensor rods The heater and drum motor shall be disabled while in this test This test must be able to run with the door open or closed The display will automatically update as the state of the clothes If display shows greater than 255...

Страница 14: ... Test The display will initially show t6 Once the start button is pushed heater 1 turns on The display shall show the value of the outlet thermistor from 00 to 137 which is considered a valid range If the value from thermistor is outside of the range there is an error in the outlet thermistor and control should display tE If the display shows a value and doesn t change the value there is a heater ...

Страница 15: ...itially show t7 Once the start button is pushed turn on heater 1 and heater 2 together The display shall show the value of the outlet thermistor from 00 to 137 which is considered a valid range If the value from thermistor is outside of the range there is an error in the outlet thermistor and control should display tE If the display shows a value and doesn t change the value there is a heater 1 or...

Страница 16: ...st 8 Error Codes If there are Errors the Display shall firstly show t8 and then the display shall show the last error code that was saved by the control for 1 second Pressing start will show other stored errors on a first in and first out basis The Control shall exit and Power Off This exercise will clear all faults and allow the control to be operational again ...

Отзывы: