6

MDS SD9 Startup Guide

05-xxxxA01, Rev. 01 

 

vided with each unit (see 

Figure 5

). Strip the wire leads to 6 mm 

(1/4 inch) and insert in the wire ports. Be sure to observe proper 
polarity as shown in the 

Figure 5

.

 

Invisible 

place 

holder

 

Figure 5. DC Power Connector

 

The transceiver is designed for use with nega-
tive-ground systems only. The power supply should be 
equipped with overload protection (NEC Class 2 rating), 
to protect against a short circuit between its output ter-
minals and the radio’s power connector.

 

5.

 

Set the radio’s con

fi

guration.

 

 The transceiver is designed for 

quick installation with a minimum of software con

fi

guration 

required. 

a. Connect a PC to the transceiver’s DB-9 

 

COM1

 

 connector as 

shown in 

Figure 6

. A straight-through cable may be used in 

most applications. If desired, a cable may be built using the 
information shown on 

Page 12

 of this guide.

b. Launch a terminal communications program, such as Hyper-

Terminal (included with most Windows

 

TM

 

 systems). Press the 

 key a few times (at half-second intervals) to receive 

the ready “>” prompt on the screen. 

 

NOTE:

 

To prevent unintended keying of the transmitter during
management activities, set 

 

PTTSIG

 

 to 

 

OFF

 

, or do not

connect to Pin 6 of the 

 

COM1 

 

port.

Lead

Screws (2)

Binding

Wire Ports (2)

(Polarity: Left +, Right –)

Retaining
Screws (2)

CAUTION

POSSIBLE

EQUIPMENT

DAMAGE

ENTER

Содержание MDS SD9

Страница 1: ...Start Up Guide Preliminary MDS 05 4659A01 Rev 0 JULY 2008 MDS SD9 Software Controlled Digital Communications ...

Страница 2: ...ssociation CSA which also issues the US mark of approval CSA US The CSA Certification is in accordance with CSA STD C22 2 No 213 M1987 CSA Conditions of Approval The transceiver is not acceptable as a stand alone unit for use in the hazardous locations described above It must either be mounted within another piece of equipment which is certified for hazardous locations or installed within guidelin...

Страница 3: ...sing DSP tech nology to provide robust communications even under adverse condi tions Figure 1 SD9 Data Transceiver The transceiver is designed for trouble free operation with data equip ment provided by other manufacturers including remote terminal units RTUs programmable logic controllers PLCs flow com puters transaction terminals and similar devices NOTE Some features may not be available on all...

Страница 4: ...iagnostics DB 9 COM2 Payload Data DB 9 ANTENNA TNC A list of LED functions is presented in Table 3 on Page 10 Accessories Table 1 lists available accessories for the transceiver The contents of a shipment may have been modified to reflect customer specific requirements given at the time of order Additional accessories are available for our products Contact your factory representative for assistanc...

Страница 5: ...panel connections Table 1 SD9 Available Accessories Accessory Description Part Number DC Power Plug 2 pin polarized Mates with power connector on radio Screw terminals provided for wires threaded locking screws to prevent accidental disconnect 73 1194A39 Retrofit Kit Digital Contains all items needed to replace an existing MDS x710A C M digital transceiver 98 6190ACC1 Retrofit Kit Analog Contains ...

Страница 6: ...brackets supplied with the radio Begin by attaching the radio s mounting brackets to the bottom of the transceiver case if not already attached using the four 6 32 x 1 4 inch 6 mm screws supplied Figure 4 shows the mounting bracket dimensions NOTE To prevent moisture from entering the radio do not mount the case with the cable connectors pointing up Also dress all cables to prevent moisture from r...

Страница 7: ...rovides a clear path to the associated master station Use low loss coaxial feedline and keep the cable as short as possible 3 Connect the data equipment to COM2 on the front panel The radio is hardwired as a DCE device A straight thru cable may be used in most applications Check Table 5 on Page 14 for pin wir ing details Note The radio s LAN port is used for reprogramming the radio s firmware Refe...

Страница 8: ...esigned for quick installation with a minimum of software configuration required a Connect a PC to the transceiver s DB 9 COM1 connector as shown in Figure 6 A straight through cable may be used in most applications If desired a cable may be built using the information shown on Page 12 of this guide b Launch a terminal communications program such as Hyper Terminal included with most WindowsTM syst...

Страница 9: ...by entering RX xxx xxxx where xxx xxxx is the frequency in MHz Press The response PROGRAMMED OK indicates successful entry e Set the radio s modem type if necessary using the MODEM xxxx command where xxxx is the modem selection typically 4800 or 9600 The default setting is 9600 f Set the radio s serial data interface rate typically BAUD 9600 8N1 This completes the initial setup and configuration o...

Страница 10: ...o PORT RS232 RS485 Selects signaling standard to be used on COM2 DATA port For RS 485 operation see Reference Manual PWR 20 37 Set or display the transmit power setting PTTSIG ON OFF Set display push to talk configuration RSSI Display the Received Signal Strength Indication RTSKEY Set display how the radio responds to RTS keying Default is RTSKEY ON which causes the radio to key the transmitter wh...

Страница 11: ...ring proper data format tim ing etc LED Indicators The LED status indicators Figure 7 are an important troubleshooting aid and should be checked whenever a problem is suspected Table 3 describes the function of each status LED on the top panel of the radio In addition to the top panel LEDs the ETHERNET LAN connector has two integrated LEDs A steady green LED indicates that an Ethernet link has bee...

Страница 12: ...alarms exist the message NO ALARMS PRESENT appears on the display If an alarm does exist a two digit alarm code 00 31 is displayed and the event is identified as a Major or Minor Alarm A brief description of the alarm is also given Table 3 LED Status Indicators LED Name Description PWR Continuous Power applied no problems detected Rapid flash 5 times per second Alarm indication LAN Continuous Loca...

Страница 13: ...s a listing of event codes that may be reported by the transceiver The codes shown are a subset of a larger pool of codes used for various GE MDS products For this reason the table does not show a sequential listing of all code numbers Only the codes appli cable to this product are shown Table 4 Event Codes Event Code Event Class Description 01 Major Improper software detected for this radio model...

Страница 14: ...g the display you can determine the presence of other signals near the transceiver s operating frequency This information can be helpful in troubleshooting interference problems COM1 COM2 REFERENCE COM1 CONNECTIONS The COM1 connector is used to connect a PC to the radio for manage ment or diagnostics A straight through cable is required that connects Pin 2 RXD Pin 3 TXD and Pin 5 Ground See Figure...

Страница 15: ...19200 38400 57600 and 115200 bps asynchronous data only The COM2 connector mates with a standard DB 9 plug that is avail able from many electronics parts distributors Table 5 provides detailed pin descriptions for the COM2 data connector in RS EIA 232 mode NOTE To prevent unintended keying of the transmitter on RTS set RTSKEY to OFF or do not connect to Pin 7 RTS of the COM2 port Pin Descriptions ...

Страница 16: ...connected device 4 IN Sleep Mode Input Grounding this pin turns off most circuits in a remote radio This allows for greatly reduced power consumption yet preserves the radio s ability to be quickly brought on line See Using the Radio s Sleep Mode for details 5 Signal Ground Connects to ground negative supply potential on chassis 6 OUT Alarm Output DSR An RS 232 high space 5 0 Vdc on this pin indic...

Страница 17: ... Ω Channel Spacing 12 5 25 kHz FCC Emission Designators 12 5 kHz B W 10K6F1D F2D F3D 25 0 kHz B W 16K2F1D F2D F3D DATA CHARACTERISTICS Signaling Type EIA RS 232 DB 9 Female connector COM2 Data Rates 300 115200 bps asynchronous Data Latency 10 ms maximum PRIMARY POWER Voltage 13 8 Vdc Nominal 10 5 to 30Vdc Negative Ground Systems Only TX Supply Current 2 0 Amperes Typical 5 Watts RF Output RX Suppl...

Страница 18: ...S SD9 Startup Guide 05 xxxxA01 Rev 01 DIAGNOSTICS INTERFACE Signaling Standard RS 232 COM1 RS 232 RS 485 COM2 Connector COM1 DB 9F COM2 DB 9F Specifications are subject to change without notice or obligation ...