TO DC POWER SUPPLY

(10–30 Vdc)

RTU/PLC

(Crossover Cable

to Radio)

LOW

-LOSS FEEDLINE

(To 900 MHz 

Antenna)

INST

INST

ALLA

ALLA

TION REFERENCE CHART

TION REFERENCE CHART

ANTENNA
SYSTEM

PC RUNNING
TERMINAL
PROGRAM
(Straight-Through
Cable to Radio)

TO GPS ANTENNA

(Provides 3.3 Vdc output)

Step 1 – Mount the Transceiver

Step 2 – Install the Antennas

Step 3 – Measure & Connect Primary Power 

(10–30 Vdc)

Step 4 – Review the Transceiver’s Configuration

Network Name

—Unique name for each radio network. Required for

Remotes to associate with the Access Point. (Default name is

MDS-Mercury

.)

IP Address

—Must be a unique number to allow for IP access

through the Ethernet Port.

NOTE: A unique IP address is essential to access the web browser-based

Management System.

RF Output Power

—Adjust as necessary for regulatory compliance.

Username/Password

—Used for remote access and some Management

System features. (Username and Password default = 

admin

)

Step 5 – Connect the Data Equipment

Connect the data equipment to data port(s):
• LAN—10/100BaseT Ethernet-compatible equipment:

 Ethernet PLC (Crossover cable); Ethernet switch (Straight-Through)

• COM1—RS/EIA-232 compatible equipment (Crossover cable to serial
                  PLC/RTU)

tep 6 – Check for Normal Operation

Observe the transceiver LED status panel for the proper indications. In a normally operating system, the following LED indications s

hould be seen within 30 seconds of power-up:

WR—Lights continuouslyL

AN—On or blinks intermittently

LINK— On or blinks intermittently (Remotes: if associated)

U se PING command to test basic data link integrity between Access Point and Remotes.
I f the PING command is successful, connect the RTU/data equipment to the data port and verify normal operation.
I f the LINK LED on Remotes is not on after 2 or 3 minutes, the unit has failed to associate with the Access Point. It may be necessary t

o reposition or redirect the radio’s antenna for better reception/signal strength. Check also GPS antenna system.

C heck connected data equipment for normal operation.

Detailed instructions are contained in the Reference Manual, P/N 05-4446A01

INSTALLATION SUMMARY

BASIC CONFIGURATION DEFAULTS

TYPICAL INSTALLATION—

Remote Shown

The Management System can be accessed through the COM1 Port using a terminal emulator. The basic  items listed below, and
many other parameters and tools can be accessed through this tool. HTTP, Telnet access, and changing parameters are controlled
by password.

VALUES/RANGE

 

1–8 alphanumeric characters

 

Case-sensitive; can be mixed case

• 1–16 alphanumeric characters
• Case-sensitive; can be mixed case

Contact your Network Administrator

AP: -30 to +30 dBm    RM: 0 to +30 dBm

DEFAULT

admin (lower case)

ITEM

MGT SYSTEM MENU

Username/Password

Device Information

Network Name

Network Configuration

IP Address

Network Configuration

RF Output Power

Radio Configuration

MDS-Mercury

192.168.1.1

+30 dBm (900 model)

+20 dBm (3650 model)

Содержание MDS 05-4558A01

Страница 1: ...Start Up Guide Wireless IP Ethernet Transceiver Covering all AP and Remote Units including Mercury 900 3650 and Option Set 1 Remotes MDS 05 4558A01 Rev C December 2008 MDS Mercury Series ...

Страница 2: ...r Normal Operation 7 Resetting to Factory Defaults Use with Care 8 AIMING DIRECTIONAL ANTENNAS 8 Procedure 9 TRANSMITTER POWER AND ANTENNA TEST 10 Procedure 10 TROUBLESHOOTING 11 SPECIFICATIONS 14 TECHNICAL ASSISTANCE 16 FACTORY SERVICE 16 Copyright Notice This publication is protected by U S A copyright law Copyright 2008 GE MDS All rights reserved The center of this guide contains a chart with a...

Страница 3: ... INSTALLATION OVERVIEW There are three main requirements for installing the transceiver ade quate and stable primary power a good antenna system and the cor rect interface between the transceiver and the data device The Installation Setup Chart center of this guide shows a typical Remote installation Access Point and mobile Remote stations typically use omnidirectional antennas whereas fixed site ...

Страница 4: ...cket screws Screws extending farther than 1 4 inch 6 mm into the case may cause internal PC board damage Step 2 Install the Antenna To minimize RF interference the antenna should be mounted at least nine inches 23 cm from the connected device s sensors and other external components of the system Additional information on antenna selection and installation is provided in the Mercury Reference Manua...

Страница 5: ...protection NEC Class 2 rating to protect against a short circuit between its output terminals and the radio s power connector NOTE Typically it takes about 30 seconds for the transceiver to fully power up and may take several minutes to associate with another unit especially if GPS is required for time synchroni zation Step 4 Review the Transceiver s Configuration There are two key settings that m...

Страница 6: ... on AP locations file which contains GPS coordinates to prede termine or preselect which AP to hop with Frequency 3650 model only Operating frequency in MHz TDD Sync Mode AP only Selections are Free Run Prefer GPS and GPS Required For single channel operation the TDD Sync Mode can be set to Free Run or GPS Required Using GPS Required synchronizes the AP s transmissions to the GPS timing When the f...

Страница 7: ...m the default entry of MDS Mercury This can be changed under the Radio Configura tion Menu for both AP and Remote f Review other settings and make changes as necessary such as the unit password IP address and security g Under the Radio Configuration Menu at the Access Point set verify the following Transmit Power Settable from 30 dBm to 30 dBm AP 0 dBm to 30 dBm Remote 20 dBm for 3650 models Recei...

Страница 8: ...ll Units Observe the transceiver s LED panel See Installation Setup Chart for the proper indications In a normally operating system the radio will typically become associated in about two minutes from start up At the Access Point a If the Access Point unit is the first unit you are installing send a PING command to it through the LAN port This verifies basic LAN connectivity b If you have already ...

Страница 9: ...verify communications link integ rity with the Access Point d After the PING is successful connect the terminal equipment to the radio s data port and verify normal operation If all checks are OK you are finished with the installation at this site Resetting to Factory Defaults Use with Caution Selecting Maintenance Tools Reset to Factory Defaults sets all trans ceiver parameters back to their fact...

Страница 10: ... Date Format Time Model Device Names Console Bd Rt UTC Time Offset Device Security Wireless Security Event Log Packet Statistics GPS Status Wireless Ntwk Stat Intl Radio Stat RM Performance Trend Manage Certif RADIUS Configuration Starting Information Screen Read Only Status Redundancy Configuration AP Redundancy Config Ntwk Event Triggers Radio Event Triggers Hdwr Event Triggers Red Config Option...

Страница 11: ...s s hould be seen within 30 seconds of power up WR Lights continuouslyL AN On or blinks intermittently LINK On or blinks intermittently Remotes if associated U se PING command to test basic data link integrity between Access Point and Remotes I f the PING command is successful connect the RTU data equipment to the data port and verify normal operation I f the LINK LED on Remotes is not on after 2 ...

Страница 12: ...3 Read the RSSI level at the Remote Main Menu Performance Information Internal Radio Status 4 Optimize RSSI by slowly adjusting the direction of the antenna Watch the RSSI indication for several seconds after making each adjustment so that the RSSI accurately reflects any change in the link signal strength The less negative the number the stronger the signal 5 View the Wireless Packets Dropped and...

Страница 13: ...as a 10 minute timer after which it will return the transceiver to normal operation The Test Mode can also be terminated manually via the menu 3 Set the transmitter RF output power to 28 dBm Main Menu Radio Configuration Transmit Power NOTE The Test Mode RF power setting does not affect the output level during normal operation 4 Activate key the transmitter Main Menu Maintenance Tools Radio Test T...

Страница 14: ...ving common system difficul ties using the radio s LEDs as a guide Table 2 on Page 13 provides guidance for using the Menu System as a tool If problems cannot be resolved using the guidance provided here review the GE MDS web site s technical support area for recent soft ware firmware updates general troubleshooting help and service information Additional help is available through our Technical Su...

Страница 15: ...andwidth and pattern offset e Wrong encryption settings The Encryption Enable and Encryption Phrase must match on the AP and Remote f Wrong device authentication settings Verify settings match on AP and Remote LAN LED not lit a Verify the Ethernet cable is connected at both ends b Verify that the appropriate type of Ethernet cable is used straight through or crossover as required c Verify setting ...

Страница 16: ...IP data to WAN a Verify your IP settings b Use the PING command to test communication with units in the local radio system c If successful with local PING attempt to PING an IP unit attached to another radio d If successful with the LAN PINGs try connecting to a known unit in the WAN ExcessiveWireless Retries Possible Radio Frequency Interference RFI a If omnidirectional antennas are used consider...

Страница 17: ...kg 2 2 lb Case Die Cast Aluminum RADIO CHARACTERISTICS GENERAL Frequency Band Mercury 900 902 928 MHz Industrial Scientific Medical ISM Band Mercury 3650 3650 3700 MHz FCC Registered Band TRANSMITTER RF Output connector Mercury 900 30 to 30 dBm Mercury 3650 0 to 20 dBm Increments of 1 0 dB set by user Duty Cycle Continuous Output Impedance 50 Ohms RECEIVER Type Double conversion superheterodyne Se...

Страница 18: ...1 Div 2 Industry Canada RS 210 PROTOCOLS Ethernet IEEE 802 3 Spanning Tree Bridging VLAN IGMP TCP IP DHCP ICMP UDP TCP ARP Multicast SNTP TFTP Serial Encapsulation over IP tunneling for serial async multidrop protocols includ ing Modbus DNP 3 DF1 BSAP MANAGEMENT HTTP HTTPS TELNET SSH local console SNMPv1 v2 v3 MIB II Enterprise MIB SYSLOG MDS NETview MSTM compati ble ...

Страница 19: ...n the outside of the ship ping box and on any correspondence relating to the repair No equip ment will be accepted for repair without an SRO number A statement should accompany the radio describing in detail the trouble symptom s and a description of any associated equipment normally connected to the radio It is also important to include the name and telephone number of a person in your organizati...

Страница 20: ...GE MDS LLC Rochester NY 14620 General Business 1 585 242 9600 FAX 1 585 242 9620 Web www GEmds com 175 Science Parkway ...