NX-2192E PINPOINT SYSTEM
6
Table 10-2
ERROR CODE
DESCRIPTION
1
Node is missing.
2
Multiple node responded.
3 Communication
error.
4
Device type mismatch.
5
Auto enroll error.
6 Reserved.
7
Output programmed to non-output device.
8
Output programmed but node not enabled.
LOCATION 242 – 336 (EVEN LOC)
EVENT & TIME FOR
OUTPUTS 1 - 48
2 segments of numerical data
Segment 1 is used to select the particular event that will trigger the output. Refer to Table 10-3 for the specific events that can be
selected.
Segment 2 is used to select the amount of time an output will remain activated when an output triggers. If this location is programmed as
a zero, the output will follow the particular event.
Table 10-3
#
Event
#
Event
#
Event
0
Always On
11
Smoke Power Reset
22
Disarmed
1
AC Fail (control or exp.) does not
follow AC Fail delay time
12
Yelping Siren
23
Ready to Arm
2
Low Battery (control or exp.)
13
Steady Siren
24
Not Ready to Arm
3
Dynamic Battery Test Time
14
Any Siren
25
Fire
4
Listen In
15
Steady Siren (temporal)
26
Fire Trouble
5
Line Seizure
16
Any Siren (temporal)
27
Chime
6
Telephone Line Fault
17
Alarm Memory
28
Beeping Keypad
7
Program Mode
18
Entry
29
♦
Aux 1 Keypad Function
8
Over-current (control or exp.)
19
Exit
30
♦
Aux 2 Keypad Function
9
Box Tamper (control or exp.)
20
Entry or Exit
31
♦
Panic Keypad Function
10
Siren Tamper (control or exp.)
21
Armed
32
♦
Code Entry (set in locs 338 - 481)
♦
If set to follow condition, these events will be one second.
LOCATION 243 – 337 (ODD LOC)
SPECIAL FEATURES FOR
OUTPUTS 1 - 48
2 segments of feature selection data
Segment 1 selects the following special conditions:
1 =
"On" if output should time in minutes; "Off" if output times in seconds.
2 =
"On" if output should latch until a code is entered; “Off” for timed.
3 =
"On" if output should stop time when a code is entered.
4 =
“On” for inverted output.
5 =
“On” disables output during listen-in (only events 12-16).
6 =
Reserved.
7 =
Reserved.
8 =
Reserved.
Segment 2 selects the following partitions:
1 =
"On" if the event should activate when it occurs in Partition 1.
2 =
"On" if the event should activate when it occurs in Partition 2.
3 =
"On" if the event should activate when it occurs in Partition 3.
4 =
"On" if the event should activate when it occurs in Partition 4.
5 =
"On" if the event should activate when it occurs in Partition 5.
6 =
"On" if the event should activate when it occurs in Partition 6.
7 =
"On" if the event should activate when it occurs in Partition 7.
8 =
"On" if the event should activate when it occurs in Partition 8.