GE Interlogix KTC-511P Скачать руководство пользователя страница 8

Installation Instructions 

 

1.1.1 W

HITE 

B

ALANCE 

(ATW/AWB) 

ATW mode (default) 

In the ATW mode, the colour temperature is being monitored continuously, and the white balance 
is set automatically by an internal micro-controller. The operating colour temperature range is 
from 2500 to 9500 K. 

AWB mode 

When the switch is set to AWB (conventional white balance), a camera using white as its 
reference automatically adjusts the content of blue and red in the picture, depending on the 
scene, to provide a picture with balanced colour content. If the colour temperature of the scene is 
continuously changing, the camera can lose its colour reference; in this case, switch the camera 
to ATW.  

1.1.2 B

ACKLIGHT 

C

OMPENSATION 

(BLC ON) 

This auto BLC is a digital light-level control system. It is activated automatically by screen 
histogram (contrast) and 225-area window weighting integration. This controls iris gain and white 
balance simultaneously so that a clear object with adequate light level can be optimised. 

Central Window Weighted Average Backlight Compensation 

This method is ideal when the main subject is fixed within the screen. 

Histogram Backlight Compensation 

This method is ideal when the main subject moves within the screen. 

The combination of two types of backlighting makes it easier to arrange backlight compensation 
operation to match the imaging conditions and installation location. 

Note:

 Compensation might be insufficient when the background is extremely bright. 

1.1.3 G

AMMA 

C

ORRECTION 

(r

 

= .45 / r

 

= 1) 

Gamma correction is an electronic correction within the camera circuitry that matches the 
brightness level seen by the camera with the brightness level displayed on the monitor. This 
adjustment enables the monitor to display the correct level of contrast. The standard setting is .45 
(default). The manual switch should be used only if the controls on the monitor are not giving 
sufficient adjustment. 

1.1.4 S

YNCHRONISATION 

(L-LOCK/INT) 

Line-Lock (external) (default) 

The sync pulses are referenced to the supply frequency. The phase adjust buttons are used to 
synchronise cameras even when they are connected to different phases of the mains supply, 
which results in roll-free pictures 

Internal 

An internal sync generator is used when the camera is being powered off of 12 VDC. 

1.1.5 A

UTO

/M

ANUAL 

S

WITCH 

(D

AY

/N

IGHT ONLY

In auto mode, the camera automatically switches from colour mode to black and white mode as 
light decreases.  In manual mode, you can manually switch the camera from daytime colour mode 
to nighttime B/W mode using the Day/Night switch (see section 1.1.6). 

Содержание KTC-511P

Страница 1: ...lution TVL 450 450 600 600 600 600 380 380 480 480 480 480 480 480 480 480 Sensitivity 0 03 0 03 0 02 0 02 0 01 0 01 0 5 0 5 0 3 0 3 0 1 0 1 0 3 0 3 0 1 0 0 1 0 IR Sensitive CCD Size inches 1 3 1 3 1...

Страница 2: ...DIP SWITCH 7 1 1 1 White Balance ATW AWB 8 1 1 2 Backlight Compensation BLC ON 8 1 1 3 Gamma Correction r 45 r 1 8 1 1 4 Synchronisation L LOCK INT 8 1 1 5 Auto Manual Switch Day Night only 8 1 1 6 D...

Страница 3: ...connection Only operate low voltage cameras from a Class 2 isolated power supply The GE series of CCTV cameras are designed for use in general purpose CCTV applications Only operate the cameras betwee...

Страница 4: ...ch is set to VD when using an auto iris lens A Direct Drive lens is controlled internally from the camera and automatically adjusts the iris to the varying light levels To adjust the level of the lens...

Страница 5: ...ntrol panel Iris connector Back focus thumbwheel Thumbwheel locking screw and provided screwdriver Figure 1 Parts of the camera Note Lens not included Note The bracket used with the mounting threads i...

Страница 6: ...to correspond with the lens For an auto iris lens without amplifier DC type set the lens mode switch to DD For an auto iris lens with built in amplifier VIDEO type set the lens mode switch to VD For a...

Страница 7: ...EE amp follow the connections in Figure 5 Refer to the lens instructions 1 1 SETTING THE DIP SWITCH Set the DIP switch for your camera situation see Figure 6 and Table 1 Table 1 DIP switch settings A...

Страница 8: ...e main subject moves within the screen The combination of two types of backlighting makes it easier to arrange backlight compensation operation to match the imaging conditions and installation locatio...

Страница 9: ...wer supply The unit can accept an AC power source input from 85 VAC to 265 VAC Note Power is now being supplied to the camera and the power LED illuminates If the LED is not illuminated check the term...

Страница 10: ...ION The phase adjustment must be made by a qualified service person or installer The vertical phase of the camera video signal can be synchronised to the phase of the AC power line by using a dual tra...