Concord
16
Figure 13. Connecting Exterior and Interior Sirens
Note
The volume switch settings
inside the siren do not affect
the siren output.
Slim Line Hardwire Interior Siren (60-483-01)
Connect the siren to the panel as shown in Figure 14.
Figure 14. Connecting the Slim Line Hardwire Interior Siren to the Panel
Installing Supervised Wireless Sirens (60-736-95)
Note
Power Line Carrier Card
must be installed for Super-
vised Wireless Sirens to
work.
Supervised Wireless Sirens (SWS) plug directly into electrical outlets and are not wired to the
panel. The panel (when powered by a line carrier power transformer) sends alarm and status mes-
sages to the siren, along the building AC wiring.
For supervised operation, the siren has a built-in transmitter that, when learned into panel mem-
ory, transmits to the panel receiver if the siren has a low battery or other trouble condition.
Before
plugging in Supervised Wireless Sirens, the panel must be powered up and partition
House Codes and the SWS Supervision Code set (in program mode) to the desired settings.
The following procedures describe the basic steps for installing Supervised Wireless Sirens. For
complete installation details, refer to the
Supervised Wireless Siren Installation Instructions
,
included with each siren.
Note
Regardless of supervised or
unsupervised siren installa-
tion, you must follow the
order of installation as
described to avoid learning
the wrong (or undesired)
House Code and SWS
Supervision Code into siren
memory.
¾
For unsupervised wireless siren installations:
1.
Power up the panel (see “Powering Up the Panel”).
2.
Enter program mode and set the partition House Code to the desired setting (see the
LIGHT
CONTROL
menu in the section “Programming the Panel”).
3.
Exit program mode.
4.
Install the siren backup battery.
5.
Plug the siren into an electrical outlet.
6.
Press the STATUS button on any working touchpad. The siren should beep once and the
siren LED should flash 5 times, indicating it has learned the partition House Code.
7.
If the siren doesn’t beep or the LED doesn’t flash, reset the house code on the siren by press-
ing and holding its button for 20 seconds. The siren will beep three times when the memory
has been cleared. Repeat step 6.
¾
For supervised wireless siren installations:
Note
Hardwire Concord™ panels
must have a SuperBus 2000
RF Receiver installed for
supervised wireless siren
operation.
1.
Power up the panel (see “Powering Up the Panel”).
2.
Install the siren backup battery.
3.
Clear the siren memory by pressing and holding the siren button for 20 seconds. The siren
will beep three times when the memory has been cleared.
Panel
Terminals
Black
Red
Red
Black
Panel Terminals
2k Ohm
Resistor
49-454
+12V Out 1
4
9
4
10
Exterior
Interior
4
1 0
+ 1 2 V
O U T 2
1
H I G H
2
G N D
3
L O W
Panel
Terminals
Not
Used
HIGH GND LOW
1
2
3