5812-RND Acoustic Glassbreak Detector

Selecting the Best Location for
Multiple Window Coverage

The detector has a 360degree coverage pattern that can be
used to cover several windows in a single room as follows:

Draw an imaginary line from the center of each window
to be covered in towards the center of the room.

Mount the detector as close to where the lines intersect
as possible. See Figure 3.

Do not mount the detector at more than a 60 degree
angle from the center of any window to be protected.
See Figure 3.

Installing the Detector

All wiring must conform to the National Electric Code
(NEC) and/or local codes having jursidiction.

Important !

Important !

Important !

Important !

Important !

If you are unsure about a location, connect a 9V
battery to the detector and test it before
permanently mounting. 
See Testing the Detector.

Use the following steps to install the detector:

1.   Run the security system wiring to the detector location.

2.   To remove the front cover, press the release tab on the

lip of the base, twist the cover counter clockwise, and
lift off. See Figure 4.

3.   Remove the appropriate wiring and mounting

knockout holes from the base. See Figure 6.

4.   Pull the wires through the knockout holes and use two

screws to attach the base to the surface. Use wall
anchors if necessary.

5.   Strip 1/4 inch of insulation from each wire.

6.   Connect the system wires to the appropriate screw

terminals on the base and tighten the screws. See
Figure 7.

7.   To replace the cover, line up the tabs on the base with

the corresponding tabs on the cover, press together
and turn clockwise until the cover snaps firmly into
place. See Figure 5.

8.   Apply power. The red LED should flash once.

9. Test the detector. See Testing the Detector.

Figure 3. Multiple Window Coverage

Figure 4. Housing Parts

Figure 5. Attaching the Cover

Figure 6. Detector Knockout Locations

Ceiling

Ceiling

Ceiling

Ceiling

Ceiling
mount

mount

mount

mount

mount

Detector

60  max.

60  max.

Microphone

LED

Release tab

Knockouts

Содержание 5812RND - Security ShatterPro III Acoustic Glassbreak Sensor

Страница 1: ...ws and wall anchors Flat blade screwdriver Phillips screwdriver Sentrol 5709C hand held tester Selecting a Location for the Detector The detector can be mounted on ceilings or on walls opposite or adjacent to the window to be protected See Figure 2 Use the following guidelines to determine the best location to install the detector Mount at least 5 feet 1 5 m from glass windows being protected Wind...

Страница 2: ...the security system wiring to the detector location 2 To remove the front cover press the release tab on the lip of the base twist the cover counter clockwise and lift off See Figure 4 3 Remove the appropriate wiring and mounting knockout holes from the base See Figure 6 4 Pull the wires through the knockout holes and use two screws to attach the base to the surface Use wall anchors if necessary 5...

Страница 3: ...the detector See Figure 8 Activate the tester The LED on the detector lights for 4 seconds and then starts flashing to indicate the detector is in test mode The relay opens for 4 seconds then returns to standby 3 Hold the tester near the surface of the glass to be pro tected and aim the speaker at the detector Be sure the tester is at the point on the glass farthestfrom the detector If closed drap...

Страница 4: ... Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Specifications Input voltage 12VDCNominal Current Typical 15mA Maximum 25mA Electrical configuration FormA Relay rating 16V 50mAmax Detection range 5 25 1 5m 7 6m x360 use for rooms 100 s...

Отзывы: