5812-RND Acoustic Glassbreak Detector

Acoustic Glassbreak
Detector

5812-RND

Installation Instructions

Description

The 5812-RND is an acoustic glassbreak detector designed
to detect breaking glass from framed windows in the
perimeter of a building. The detector is mounted in the
building interior and uses a power supply from a 12VDC
control panel. The detector is available in a low-profile
round housing.

Features

The detector provides the following features:

Range - 5 to 25 feet (1.5 to 7.6 m)

Alarm memory - After an alarm and until power is
cycled, the alarm memory can be checked with the hand-
clap test.

LED indicator - Red LED provides detector test and
status indication.

Tamper resistant - Provides a screw that secures the
cover to the base to prevent tampering.

Hand-clap test - In addition to a test mode, you can
confirm the operation of the microphone by clapping
your hands.

What You Will Need

You need the following tools and parts to install the
detector:

5812-RND detector including screw to secure the cover
to the base

Screws and wall anchors

Flat-blade screwdriver

Phillips screwdriver

Sentrol 5709C hand-held tester

Selecting a Location for the
Detector

The detector can be mounted on ceilings or on walls
opposite or adjacent to the window to be protected.  See
Figure 2.

Use the following guidelines to determine the best location
to install the detector.

Mount at least 5 feet (1.5 m) from glass windows
being protected.

Windows must be at least 12 x 24 inches
(30.5 x 61 cm) square.

Avoid locations where lined, insulating, or sound
deadening drapes are used.

Mount 12 inches (30.5 cm) away from wall corners.

Avoid locations where interior closed wooden
shutters are used.

Locate in a suitable envionment as follows:

- Temperature between 32° and 122°F (0° and 50°C)

- Humidity between 10 and 90% non-condensing

Mount the detector on a stable surface up to 25 feet
(7.6 m) from the farthest point on the glass surface.
See Figure 2.

Avoid locations that expose the detector to possible
false alarm sources such as:

- Glass airlocks and vestibule areas

- Kitchens

- Residential car garages

- Small utility rooms

- Stairwells

- Bathrooms

- Small acoustically live rooms

- Air vents

Figure 1. 5812-RND

Figure 2. Mounting Locations

Wall mount

Ceiling mount

25’ (7.6m)
max.

25’ (7.6m)
max.

UL

¤

C

LISTED

US

Содержание 5812RND - Security ShatterPro III Acoustic Glassbreak Sensor

Страница 1: ...ws and wall anchors Flat blade screwdriver Phillips screwdriver Sentrol 5709C hand held tester Selecting a Location for the Detector The detector can be mounted on ceilings or on walls opposite or adjacent to the window to be protected See Figure 2 Use the following guidelines to determine the best location to install the detector Mount at least 5 feet 1 5 m from glass windows being protected Wind...

Страница 2: ...the security system wiring to the detector location 2 To remove the front cover press the release tab on the lip of the base twist the cover counter clockwise and lift off See Figure 4 3 Remove the appropriate wiring and mounting knockout holes from the base See Figure 6 4 Pull the wires through the knockout holes and use two screws to attach the base to the surface Use wall anchors if necessary 5...

Страница 3: ...the detector See Figure 8 Activate the tester The LED on the detector lights for 4 seconds and then starts flashing to indicate the detector is in test mode The relay opens for 4 seconds then returns to standby 3 Hold the tester near the surface of the glass to be pro tected and aim the speaker at the detector Be sure the tester is at the point on the glass farthestfrom the detector If closed drap...

Страница 4: ... Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Specifications Input voltage 12VDCNominal Current Typical 15mA Maximum 25mA Electrical configuration FormA Relay rating 16V 50mAmax Detection range 5 25 1 5m 7 6m x360 use for rooms 100 s...

Отзывы: