MA-005 - MINITRANS Installation Manual - Rev 3.1
29-Sep-15
Page 65 of 85
Attach the parts for the failsafe mechanism to the remaining threaded inserts in the
support bracket as shown in the images of Figure L—17 and tighten with the Allen
key.
Note: If necessary, use the spanner to tighten the nut (recommended torque is 5 Nm).
Figure L—17: Fitting the failsafe mechanism
L.5.6
Connect the flexible braided tubing to the inlet and outlet ports of the product.
Two 1 metre lengths of flexible braided tubing are supplied in each installation kit.
These need to be connected to the inlet and outlet ports of the product to
minimise vibration from rigid pipework.
allow for position change from the original position (retrofit installations only), so
as not to put stress on the swaged joints and potentially cause leaks.
allow for potential movement of the isolator over time. This would cause the
position of the product to change, which may put stress on the swaged joints
and potentially cause leaks.
M6 nut, washer and
spring washer