User Manual 6214
MAN10xxx-01 39
Label Calibration Button
A hardware button to make a Label Calibration while printer encountering ‘’Media Error’’ during the cases
when first-time printer start up or change label or ribbon to another type, such as change using gap label to
continuous or black mark labels.
Keep pressing calibration button for 1 second, the printer can immediately run the label size calibration.
Press C-button for 2 seconds, it will make an auto-sensing to calibrate the label and ribbon’s parameters.
Notice
*
***
Press C-button is equivalent to the auto-sensing command ‘’~S,SENSOR’’ that will cancel on-printing-job and make
the Label Calibration immediately.
.