GDS 99-0010 Скачать руководство пользователя страница 2

TEST GAS KIT – PART No 99-0010 / 99-0020

110 LT GAS CAPACITY (1.6LT WATER CAPACITY) –  
FIXED FLOW REGULATOR

    

•  

Ensure regulator control knob is closed (clockwise) before use. 

•  

Screw onto outlet of the can until it stops and pressure registers  
on the gauge. 

• 

The regulator may now be opened by turning the control knob  
anti-clockwise. Gas will now be delivered at a pre-set flow rate. 

• 

Always remove regulators after use. All cans will re-seal upon 
removal, there may be a “hiss” of gas when removal takes place.

• 

Attach the test gas applicator attachment to one end of the plastic 
sample pipe.

• 

Connect the other end of the sample pipe to the output nozzle  
of the regulator.

• 

Turn the regulator adjuster anti-clockwise until a flow of gas is 
obtained from the sample pipe.

• 

Screw the test gas applicator onto the sensor.

• 

When the gas monitor meter reading has achieved a maximum 
steady reading adjust the calibration potentiometer  
for the required meter reading.

• 

Remove the test gas applicator and allow the meter to return to zero.