8
SPECIFICATIONS
Power
+12-30VDC, +24VDC, +12VDC or 110/220VAC depending on configuration and
peripherals. Radio and display require 3 watts maximum.
Display
64 x128 pixel LCD with engineering units, bargraph and 30-minute trend
Input
Monitors up to 32 channels of wireless gas detection from GASMAX/TX wireless gas
detectors. Supports GDS Corp networks “A” through “Z”
Output
Four programmable SPDT relays and one dedicated fault SPDT relay. Relays are rated for
5A @ 110/220VAC or 24VDC.
Output
Rebroadcasts wireless data packets (programmable on a per-channel basis)
RF Section
(900 MHz)
Receiver sensitivity -100 dBm
Frequency range 902 to 928 MHZ.
Repeater function: User adjustable transmit power from 10 mW to 1.0 watt
RF Section
(2.4 GHz)
Receiver sensitivity -100 dBm
Frequency range from 2.406 GHz to 2.435 GHz (network identifier A – R) and from 2.444
GHz to 2.472 GHz (network identifier S – Z)
Repeater function: Fixed transmit power of 50 mW.
Temperature Operating -40°C to +55°C
Memory
On-board non-volatile memory retains all user settings
Housing
Aluminum housing(s) with epoxy paint standard; #316 stainless steel optional
Dimensions
See dimensional drawings in Chapter 10.
Approvals
Enclosure CSA certified for Class I Division 1 hazardous areas
Warranty
Two years on electronics