GDS Corp C2 Quad Protector Скачать руководство пользователя страница 2

Quickstart Guide 

C2 

Quad Protector 

Controller with  

Remote GASMAX EC Gas Monitor 

GDS Corp.      2513 Hwy 646 Santa Fe, Texas 77510      (409) 927-2980      (409) 927-4180 fax  

www.gdscorp.com      [email protected] 

C2 QUAD ANALOG INPUT BOARD 

P/N #10-0221-4 

Wiring & Initial Setup Instructions  

1)  Install the C2 

Quad Protector 

controller and remote 

GASMAX EC gas monitor. As with all sensors, avoid 
locations subject to excessive heat, directed water spray 
or dust. A splash guard is recommended on all externally-
mounted sensors.  

2) Connect the C2 Quad Protector input terminals to the 

remote GASMAX EC monitor as shown below.  The 
GASMAX EC output is non-polarized; either wire can be 
connected to the +24VDC excitation pin.  

3) Make sure the selected C2 channel is set to “ON” (see 

the C2 manual, section 2.2.4d).  

4) Calibrate the unit to verify proper operation.  

GASMAX / EC DISPLAY ASSEMBLY 

P/N #10-0232 

Important: 

 

The GASMAX / EC loop output 

is non-polarized. Either 

GASMAX / EC output may be 

connected to the +24VDC 

terminal on the C2 Quad.  

Отзывы: