F 8S & F 8ST Natural Gas

Category of Appliance  

F 8S

II

2H3P

Category of Appliance  

F 8ST

I

2H

The appliance is set for Gas Type G20 at 20mbar.

Heat Input 

(gross) High Med Low

Low

kW

3.06

2.21 1.50

1.27

Btu/h

10,440 7,540 5,118 4,333

Heat Output 

(gross) High Med Low

Low

kW

2.26

1.48 0.6

0.80

Btu/h

7,700 5,050 2,047 2,730

Setting Pressure

Cold

F Range

mbar

19.25 ± 0.75

in wg

7.7 ± 0.3

Setting Pressure

Cold

Comfortstat

mbar

20.00 ± 1.00

in wg

8.0 ± 0.4

Injector Size

CO

1

Nox Class

2

Gas Rate

on HIGH

0.29 m

3

/h (10.28 ft

3

/h)

Gas Connection

F 8S - 

1

/

4

(

1

/

4

BSP external)

F 8ST 

- 8mm nut and olive

Ignition

Piezo Spark 

Packed Weight

F 8S & F 8ST

24.4 kg (54 lbs)

Dimensions

F 8S 

F 8ST

Height

430mm

430mm

Width

516mm

516mm

Depth

152mm

170mm

(from the wall)

Controls

Rotary gas tap allowing

Non Thermostat

manual adjustment 

between low, medium 

and high output.

Flame failure device.

Controls

Rotary thermostat allowing

Comfortstat

a lowt position and 

adjustment between low and 

high temperature settings.

Flame failure device.

Thermocouple

Output

8-13mv

Heat Exchanger

Cast Iron

2.0 Technical Data  

F 5 & F 5S Natural Gas

Category of Appliance     

II

2H3P

The appliance is set for Gas Type G20 at 20mbar.

Heat Input 

(gross) High

Med

Low

kW

2.05

1.41

0.86

Btu/h

7,000

4,800

3,000

Heat Output

(gross) High

Med

Low

kW

1.5

0.98

0.57

Btu/h

5,100

3,350

1,950

Setting Pressure

Cold

mbar

19.7 ± 0.75

in wg

7.9 ± 0.3

Injector Size

CO

2

Nox Class

3

Gas Rate

on HIGH

0.195 m

3

/h (6.89 ft

3

/h)

Gas Connection

1

/

4

(

1

/

4

BSP external)

Ignition

Piezo Spark 

Packed Weight

F 5

F 5S

18 kg

18.4 kg

(39.7 lbs)

(40.6 lbs)

Dimensions

F 5

F 5S

Height

394mm

394mm

Width

426mm

450mm

Depth

126mm

128mm

(from the wall)

Controls

Rotary gas tap allowing

manual adjustment 

between low, medium 

and high output.

Flame failure device.

Thermocouple

Output

8-13mv

Heat Exchanger

Cast Iron

Except

Comfort

Stat 

Comfort

Stat 

Except

Comfort

Stat 

Comfort

Stat 

Installer Guide

Except

Comfort

Stat 

Except

Comfort

Stat 

© GDC Group Ltd. 2012

Содержание Comfortstat 2 F 8ST

Страница 1: ...omfortstat 2 F 8ST Balanced Flue Gas Wall Heaters Installation and Owner Guide Please leave these instructions with the user 5131922 05 Brazilia F 5 Brazilia F 5S Brazilia F 8ST Comfortstat 2 Brazilia...

Страница 2: ...tabase or transmitted in any form or by any means whether electronic mechanical recording or otherwise without the prior written permission of the copyright owner Applications for the copyright owner...

Страница 3: ...0 Warranty Service 26 6 0 Warning 28 Section Page s Contents Installer Before continuing any further with the installation of this appliance please read the following guide to manual handling The lift...

Страница 4: ...rangement Except for Comfortstat the appliance is controlled by a control knob which operates the ignition and alters the heat output The control knob has five positions giving a choice of three outpu...

Страница 5: ...e Regulations Failure to install the appliance correctly could lead to prosecution GAS SAFE REGISTER and CORGI require their members to work to recognised standards In the United Kingdom the installat...

Страница 6: ...thermostat allowing Comfortstat a lowt position and adjustment between low and high temperature settings Flame failure device Thermocouple Output 8 13mv Heat Exchanger Cast Iron 2 0 Technical Data F...

Страница 7: ...ermocouple Output 8 13mv Heat Exchanger Cast Iron 2 0 Technical Data F 5 F 5S Propane When converted using kit No 5110284 Category of Appliance II2H3P The appliance is set for Gas Type G31 at 37mbar H...

Страница 8: ...Installations in Timber Framed Dwellings 3 2 Clearances 1 The appliance must be fitted on a vertical flat non combustible wall Any combustible wall coverings should be removed from within the area of...

Страница 9: ...of being opened or any ventilation inlet or similar opening no part of the terminal shall be within 300mm 1 ft measured vertically from the bottom of the opening b Where the flue terminal of the appli...

Страница 10: ...r use in habitable rooms and must not be fitted in cupboards or confined compartments 3 6 Gas Supply 1 The inlet connection is located on the gas tap at the bottom right hand side of the appliance Com...

Страница 11: ...n Adjust the distance from the back of the airbox and the joint between the terminal and air duct to this dimension Using the length of flue tape provided fix this dimension by taping up the joint bet...

Страница 12: ...mpleted 1 Push in and turn the control knob back to the OFF position 2 On models not fitted with the Comfortstat control remove the knob from the appliance by gently pulling the knob forward Fig 12 3...

Страница 13: ...asting If necessary clean the viewing window 14 With a light brush carefully remove deposits from the spark electrode burner flame ports and the burner gauze Fig 17 15 Replace the rope seal in the hea...

Страница 14: ...emove the three screws holding the burner retaining plate to the airbox and undo the thermocouple nut from the gas tap Fig 23 25 3 Ease the thermocouple and electrode leads from the rubber grommet Fig...

Страница 15: ...on hole Fig 27 8 Reassemble in reverse order of dismantling 7 5 Injector 1 Remove the burner as described in sections 7 4 1 to 7 4 4 2 Undo the injector and sealing washer retaining the washer for use...

Страница 16: ...thermocouple nut from the gas tap Fig 31 33 3 Ease the thermocouple and electrode leads from the rubber grommet Fig 32 4 Disengage the burner from the injector and pull the electrode lead off the spa...

Страница 17: ...ner inlet ensuring that it covers the primary aeration hole Fig 35 8 Reassemble in reverse order of dismantling 8 4 Injector 1 Remove the burner as described in sections 8 3 1 to 8 3 4 2 Undo the inje...

Страница 18: ...18 8 0 Fault Finding 3 5 0 5mm 7 1 5mm Fig 38 Ensure all installation criteria have been satisfied before performing Fault Finding e g flue terminal position Installer Guide GDC Group Ltd 2012...

Страница 19: ...042941 I 381941 Injector F 5 F 5S 224047 J 381942 Injector F 8S F 8ST 224104 K 205791 Washer For injector 082365 L 205844 Insulation F 5 F 5S 224048 M E01359 Insulation F 8S F 8ST 223971 N 155654 Lead...

Страница 20: ...Owner Guide Brazilia F 5 Brazilia F 5S Brazilia F 8ST Comfortstat 2 Brazilia F 8S GDC Group Ltd 2012...

Страница 21: ...djacent to any heating appliance The likelihood of wall staining from convected air currents will be increased in environments where high levels of tobacco smoke or other contaminants exist GDC Group...

Страница 22: ...ter the burner ready for ignition Keep the knob pushed in for 20 seconds and the burner should remain alight If not repeat the sequence NOTE Under extreme wind conditions more than one attempt to ligh...

Страница 23: ...ep the knob pushed in for 10 seconds and the burner should remain alight If not repeat the sequence NOTE Under extreme wind conditions more than one attempt to light the appliance may be required 3 On...

Страница 24: ...learances 1 Internally the appliance must not be fitted under a shelf or sill that projects more than 150mm 6in 2 Curtains or a shelf must not be closer to the top of the outer case than 140mm 51 2in...

Страница 25: ...stomers suffering from arthritis or similar conditions and provides the user with extra leverage when operating the control knob It is available from Spares Stockists 4 2 Running Costs 1 The running c...

Страница 26: ...customer service team is on hand to help Simply call our GDC Group Technical helpline on In the United Kingdom Telephone 0844 879 35 88 In the Republic of Ireland Telephone 01 842 8222 When calling t...

Страница 27: ...etails Block Capitals Installer Name Gas Safe Register or Corgi Registration Number Company Name Company Address Company Telephone number Company Fax number Owner Guide Information label location Fig...

Страница 28: ...rt period These are harmless and will quickly clear away during use Parts of the grille or casing will become hot during use A fireguard conforming to BS8423 should be used for the protection of the e...

Отзывы: