Expert Pro User Manual
The Control Panel 3-8
19200, e, 7, 1, p
19200pbs, 7 Bits with EVEN Parity
19200, n, 8, 1, p
19200pbs, 8 Bits with NO Parity
19200, o, 8, 1, p
19200pbs, 8 Bits with ODD Parity
19200, e, 8, 1, p
19200pbs, 8 Bits with EVEN Parity
Firmware
Version
To display the version number of Firmware and FPGA code.
Select
Language
To select displayed languages on LCM panel in English,
Spanish, Italian, Deutsch, Japanese, Portuguese, Polish,
Turkish or French.
English
Select Units
Provide four-unit systems for users convenient.
cm/gram; inch/oz;
cm/oz; inch/gram
Metric
Image Scale
Length
Image Scale
Width
To adjust the image scale of media length and width that may
cause by the thickness of the media.
The Numerator is the ideal length, and the Denominator is the
actual length measured from the resultant.
For example, cutting a line with 500.0 mm length. The
procedure as follows:
1. Press the [LEFT ARROW] to choose the Numerator and
select 500.0 mm,
2. Cut the length by sending a graph file,
3. Measure the length then use the [RIGHT ARROW] key to
choose the Denominator, then
4. Press [UP ARROW /DOWN ARROW] to change the
values of the actual length.
500/500 mm
Scale Length
Scale Width
Fixed scaling, for maintenance only.