High Tone Power Therapy Device

HiToP

®

Metabol

User Manual

Содержание HiToP Metabol

Страница 1: ...High Tone Power Therapy Device HiToP Metabol User Manual...

Страница 2: ...missions All rights reserved No part of this manual may be reproduced in any form or by any means electronic mechanical or otherwise without the prior written permission of the gbo Medizintechnik AG V...

Страница 3: ...ol 3 gbo Medizintechnik AG Version 1 4 Warnings and safety precautions Warning Warnings which have to be observed by all means Caution Observe the instructions for use Note Information which facilitat...

Страница 4: ...and installation 10 3 2 Connection and switch on 10 3 2 1 Voltage change over and fuses 11 3 3 Basic settings 12 3 3 1 Treatment time 12 3 3 2 Language 12 3 4 Important notes and safety precautions 13...

Страница 5: ...of 4096 32768 Hz The therapy frequency is scanned with a defined frequency This method is called SimulFAM for Simultanous Frequency Amplitude Modulation In the following the basic method is divided i...

Страница 6: ...l panel HiToP Int SimulFAM X Figure 1 Control panel 2 1 1 Ergonomic control panel The control panel possesses a display the white Softkey two function keys and the Intensity regulator These elements a...

Страница 7: ...iew 2 1 4 Function keys HiToP Metabol is equipped with two black Function keys These are easy to feel and also have a pressure point With them you can scroll through the display indications so that yo...

Страница 8: ...en the other electrode on the black side with Aloe Vera spray Then push the electrode down between leg and strap The black side of the electrode must point towards your skin Now fix the electrodes wit...

Страница 9: ...bly several turns clockwise The therapy has started During treatment you can change the intensity While changing the intensity you will always notice a pulsation The display shows the treatment time r...

Страница 10: ...portant notes and safety precautions Warning The unit is not designed to be used at non explosion proof places If it is used in dangerous areas of anesthesia departments the possibility of an explosio...

Страница 11: ...iver the box can be pulled out of the receiver by the small slot Warning The mains socket is sealed with a scotch tape This is to remind to check prior to switch on whether the voltage set corresponds...

Страница 12: ...ngs with the arrow keys After selection confirm your choice with the white softkey and you can modify the values 3 3 1 Treatment time The treatment time can be set in steps of 5 minutes between 30 and...

Страница 13: ...he patient cable is in direct range of high frequency short wave or micro wave therapeutic devices a damage to the device or an injury of the patient cannot be excluded Please keep a distance of at le...

Страница 14: ...treatment decrease the intensity to 0 by turning the intensity knob counterclockwise 4 2 Treatment details 1 Switch on the unit 2 You see the start display 3 In the display the following message appe...

Страница 15: ...eps of seconds When the treatment timer reaches zero the unit stops the treatment and the intensity is set to zero The values for voltage U and current I can be used as an indicator for the following...

Страница 16: ...ncy of treatment The duration of treatment is pre set to 60 minutes In the basic settings the treatment time can be set from 30 to 60 minutes Treatment of osteoarthrosis can be executed three times a...

Страница 17: ...Plug in the patient plug of the distribution cable to the socket of the unit 4 Wet the conductive rubber electrodes with Aloe contact spray to avoid current sensations on the skin 5 If you want to use...

Страница 18: ...arried out on the basis of this directive Here the operator regulation has to be especially observed Irrespective of the legal rules or beyond the scope of the Medical Device Directive it is recommend...

Страница 19: ...me warm water Wash off the rest of the aloe vera contact spray Dry the electrodes with a cleaning tissue or let them air dry Note The conductivity of the electrodes is optimized by using a big part of...

Страница 20: ...accordance to IEC 601 Protection against ingress of water IP X1 Dimensions 6 cm x 23 cm x 32 cm H x D x W Weight max 3 7 kg without accessories Color white RAL 9002 and grey RAL 7016 Display LCD back...

Страница 21: ...on HiToP Metabol Mains cable Registration cards 017 0 0016 Distribution cable I red 150 cm 017 0 0030 Set of patient cables red 6 pcs 100 cm each 017 0 0034 Rubber electrodes 115 x 175 2 St ck 017 0 0...

Страница 22: ...tient plug removed This error message appears when the connector is unplugged during therapy or the connector has a loose contact Error 3 current monitoring This error message appears when contact pro...

Страница 23: ...by the manufacturer is 10 years The HiToP 191 is an electronic device For its disposal the respective regulations for electronic devices must be observed Incidentals have to be disposed with residual...

Страница 24: ...ity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete...

Страница 25: ...MHz to 800 MHz d 2 3 P for 800 MHz to 2 5 GHz Where P is the maximum output power rating of the transmitter in watts according to the transmitter manufacturer and d is the recommended separation dist...

Страница 26: ...Connection and switch on 11 Disinfection 19 Display 7 F Function keys 8 Fuses 12 G Graphic display 7 H High Tone Therapy 6 I Intensity regulator 8 N note 15 S Safety controls 19 Softkey 8 Supply chan...