MOVING AND POSITIONING THE HEATER
For lifting and moving the heater, please use appropriate equipment
able to sustain its weight. Do not use a forklift to move the heater.
Avoid positioning the heater on uneven or unlevel ground. Never
move the heater during use. When moving the unit, remove the
glass tube to prevent accidental damage.
HOW IT WORKS
The heater works through pyrolysis, a
natural chemical process that
generates biogas. Not the pellets
themselves but the biogas generated
creates the flame. The process
diminishes the more the combustion of
pellets exhausts itself. The remaining
residue is called char.
The temperature within the hopper
cannot be controlled nor blocked as
the natural process of combustion
takes place.
The pellets burn from the top down, therefore pellets should never
be added to the heater until the prior load has burned down
completely. Discharge the hopper of char afterwards and only then
refill with more pellets.
INITIAL OPERATION
Use the directions for NORMAL OPERATION on the next page
taking note of the following:
• Load the hopper with only 3-4kg of pellets.
• It is normal for the heater to emit white smoke and odours upon
the first few firings. This will subside with subsequent firings.
• Completely clean and empty the heater according to following
instructions before the next firing.
FUEL THIS APPLIANCE WITH WOOD HEATING PELLETS ONLY
Fresh Air
Pellets
Pyrolysis
Zone
Char
Hot
Biogas