5. Installation Instructions
ELECTRICAL CONNECTION
This appliance must be connected by a competent person, using fixed wiring via a double
pole switched fused spur outlet with a fuse rating of 3amps, and with a contact separation
of at least 3mm in all poles.
We recommend that the appliance is connected by a qualified electrician who will comply
with I.E.E. regulations.
The wires in the mains lead are coloured in accordance with the following code: Green &
Yellow = Earth, Blue = Neutral, Brown = Live.
GAS CONNECTION
The appliance’s gas inlet fitting is a 1/2” male threaded cylindrical gas type in accordance
with the ISO 228-1 standards. Make the connection using rigid pipe.
This appliance is adjusted for
NATURAL GAS
at 20mbar
ONLY.
The hob is suitable for conversion to Liquid Petroleum Gas BUTANE (G30) at 28-
30 mbar and PROPANE (G31) at 37 mbar by the following procedure using the kit
supplied.
•
Replace the injectors with the corresponding injector from the table
below.
First remove the burner caps and rings and with a socket spanner
(B), unscrew injector (A) (see fig. 9).
•
The adjustment of the reduced rate
position is as follows:
Light the burner and turn the knob to reduced rate position.
Remove the knob (M) which is simply inserted onto tap stem.
Insert a small screwdriver (D) into the top shaft (C) and turn the bypass
screw left or right until flame of the burner is conveniently regulated to the
low position (see fig.10).
•
Make sure that when turning quickly from “Full on” position to reduced rate
position that the burner does not extinguish.