background image

LIMITED WARRANTY

For “XG” Series Ventilators

May 2008

The Gaylord “XG” Series hood and component parts furnished with the hood by Gaylord Industries or the 
Licensed Gaylord Manufacturer are warranted by Gaylord Industries or the Licensed Gaylord Manufacturer 
producing ventilator to be free from defects of material and workmanship under normal use when installed, 
operated and serviced in accordance with factory recommendations.
Gaylord Industries or the Licensed Gaylord Manufacturer’s obligation under this warranty and any warran

-

ties implied in law shall be limited to repairing or replacing at its option any part of said equipment when 
Gaylord Industries or the Licensed Gaylord Manufacturer’s examination shall disclose to its satisfaction to 
be thus defective, for a period of one (1) year from date of beneficial use, or eighteen months from date 
of shipment, whichever occurs first, provided proper and acceptable evidence of such is recorder at the 
factory.  GAYLORD INDUSTRIES OR THE LICENSED GAYLORD MANUFACTURER SHALL NOT BE 
RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM A BREACH 
OF THIS WARRANTY.
In the United States the labor required to make repairs and replacements under this warranty shall be 
furnished by Gaylord Industries or the Licensed Gaylord Manufacturer or its authorized representative.  
Such labor shall only be provided Mondays through Fridays between the hours of 8 a.m. and 4 p.m.  Re

-

quests for repairs or replacement parts should be made to GAYLORD INDUSTRIES, 10900 SW Avery 
Street, Tualatin, Oregon 97062.
Outside the United States, all replacement parts furnished under this warranty shall be F.O.B. Gaylord 
Industries, Tualatin, Oregon U.S.A.  The owner shall pay the necessary freight delivery charges, and the 
necessary labor for removal and installation of parts, and any tariffs, duties or taxes. 
This  warranty  does  not  cover  routine  maintenance  or  malfunctions  or  improper  operation  caused  by        
fluctuating electrical power or power surges, and improper exhaust fan operation.
This is the sole warranty with respect to the aforesaid items.  NEITHER GAYLORD INDUSTRIES NOR 
THE GAYLORD LICENSEE NOR ANY OTHER PARTY MAKES ANY OTHER WARRANTY OF ANY KIND 
WHATSOEVER, EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY 
AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID OBLIGATIONS ARE 
HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT. 

LIMITED  WARRANTY

Содержание XG SERIES

Страница 1: ...LLATION OPERATION MAINTENANCE MANUAL for XG SERIES HOODS 10900 S W AVERY STREET TUALATIN OREGON 97062 U S A 1 800 547 9696 503 691 2010 FAX 503 692 6048 email info gaylordusa com GAYLORD INDUSTRIES EFFECTIVE DATE 5 2008 ...

Страница 2: ...dling Equipment etc please refer to the corresponding supplementary equipment manuals If you have further questions please call us toll free at 1 800 547 9696 We are more than happy to help Sincerely Gaylord Industries Street Address 10900 S W Avery Street Tualatin Oregon 97062 8549 U S A PHONE 503 691 2010 800 547 9696 FAX 503 692 6048 email gaylord gaylordusa com www gaylordusa com GAYLORD INDUS...

Страница 3: ...0 The manufacturer reserves the right to modify the materials and specifications resulting from a continuing program of product improvement or the availability of new materials ALL RIGHTS RESERVED NO PART OF THIS BOOK MAY BE REPRODUCED STORED IN A RETRIEVAL SYSTEM OR TRANSMITTED IN ANY FORM BY AN ELECTRIC ME CHANICAL PHOTOCOPYING RECORDING MEANS OR OTHERWISE WITHOUT PRIOR WRITTEN PERMISSION OF GAY...

Страница 4: ...ways have access to the inside of the extractors for easy cleaning and will not mistakenly install the units in the opened or disassemble position CLEANING At the end of the cooking day or at periodic intervals cartridges are removed and washed either in a dishwasher or soaked in a deep well sink scrubbed and rinsed FIRE PROTECTION NFPA 96 requires the use of surface duct and plenum pro tection on...

Страница 5: ...Gaylord Fire Balancing Damper Has a thermostatically activated electric Fire Balancing damper located at the duct collar Can be used in the horizontal position ND No Damper 3 Style BDL Wall canopy style BDL CL Island style for single line of cooking equipment using one extraction chamber Light Medium Duty BDL DS CL Island style for single line of cooking equipment using one extraction chamber Ligh...

Страница 6: ...are should be taken when removing extractors especially over fryers It is recommend ed that the cooking equipment be cooled down and the fryers be covered prior to removing filters INSPECTION AND CLEANING REQUIREMENTS The 1998 edition of NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations require that hoods ducts and exhaust fans be inspected by a properly...

Страница 7: ...r h t e h t r a e n d e t a c o l s r e t s i g e r r i a p u e k a M o t d e t s u j d a e b d l u o h s s r e v u o l e h t d o o h d o o h e h t m o r f y a w a r i a e h t t c e r i d e h t t a r i a p u e k a m g n i c r o f r o g n i t c e r i D s t f a r d s s o r c s e t a e r c y l l a c i p y t d o o h s s o l e k o m s n i g n i t l u s e r r o f d e i l p p u s e b t s u m r i a p u e ...

Страница 8: ...m n e e b e v a h y a m h c t i w s r o t c e l e s n o i t i s o p c i t a m o t u a e h t m o r f d e p p i r t r e k a e r b t i u c r i c n a f t s u a h x E d e s u f a h t i w d e p p i u q e s i m e t s y s e h t f I a n a f t s u a h x e e h t r o f h c t i w s t c e n n o c s i d t u o n w o l b e v a h y a m s e s u f r o e s u f d e r i w n e e b t o n s a h h c t i w s f f o n o n a F ...

Страница 9: ...termine your rate of flow for the hood per unit length of the hood Total flow will be the CFM LF obtained from Fig 9 multiplied by the length of the ventilator section 8 Design values will be noted on the listing label attached to the inside of the ventilator or sticker attached to the inside of the access cover Fig 9 Airflow vs Static Tap Chart Balancing Hood system flow rates are to be adjusted ...

Страница 10: ...18400 Extractor Removal Tool For 250 400 CFM Lin Ft Extractors Kason INCANDESCENT LIGHT LENS FRAME 12 x 12 Recessed Light Lens Retainer FLUORESCENT LIGHT LENS FRAME 2 Ft Recessed Light Lens Retainer 3 Ft Recessed Light Lens Retainer 4 Ft Recessed Light Lens Retainer 13211 13210 10111 10112 19872 EXHAUST DUCT THERMOSTATS 6 NC 325 F 19176 Damper Control Motor 24 volt For GFBD Model Dampers Control G...

Страница 11: ...Manual 7 Hoods are constructed of 18 Ga stainless steel Type 304 No 4 finish unless otherwise noted on drawings AIR FLOW RATES 8 The exhaust air flow rates and supply if part of the hood must be set at the rate stamped on the hood nameplate The exhaust volumes and supply when provided were established under controlled laboratory conditions and greater exhaust and or lesser supply may be required f...

Страница 12: ...rox 1 minute 15 seconds _____Yes ___No B The exhaust fan came on ___Yes ___No 2 Turn off the exhaust fan A The damper should move to the fully closed position in approx 15 seconds_____Yes_____No B The exhaust fan shut off ___Yes ___No INSTALLATION INCLUDES THE FOLLOWING Gaylord Auto Start Controller Gaylord Clearair Pollution Control Unit RSPC The Gaylord Quencher Fire Protection System Gaylord Di...

Страница 13: ...CH OF THIS WARRANTY In the United States the labor required to make repairs and replacements under this warranty shall be furnished by Gaylord Industries or the Licensed Gaylord Manufacturer or its authorized representative Such labor shall only be provided Mondays through Fridays between the hours of 8 a m and 4 p m Re quests for repairs or replacement parts should be made to GAYLORD INDUSTRIES 1...

Страница 14: ...est certified service agency call or write to gaylord industries FORM NO TM XG 0508 COPYRIGHT 2008 GAYLORD INDUSTRIES LITHO IN U S A 10900 s w avery street tualatin oregon 97062 u s a Call 503 691 2010 1 800 547 9696 Fax 503 692 6048 email info gaylordusa com local service agency ...