![GAYLORD XG-BDL Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/gaylord/xg-bdl/xg-bdl_installation-operation-and-maintenance_570451018.webp)
15
TROUBLESHOOTING
SYMPTOM
POSSIBLE PROBLEM
CORRECTIVE ACTION
SMOKE LOSS
1.
Smoke Loss - Hood is not exhausting
properly.
A.
Low Airflow - Static pressure at the
hoods static tap. Static values should
be in accordance with Figure 21.
1.
Broken or slipping belt on the exhaust
fan.
2. Proper rotation of the exhaust fan
wheel.
3. Proper size of the exhaust fan (fan
must deliver nameplate rating).
4.
Ductwork inspection panel left open.
5.
Exhaust duct fire damper not open or
in proper position
B. The hood must have its own exhaust
system and no other exhaust, such
as dishwasher hoods, should be tied
into it.
1.
Inspect duct system and verify that
there are no other non hood systems
tied in. If so, they must be removed.
C. Improperly placed make-up air
diffusers
1.
Make-up air directed at the hood will
likely create cross drafts disrupting
the airflow into the hood. Adjust the
louvers to direct the make-up air away
from the hood.
2. Make-up air should be delivered
through the registers at ceiling height,
and distributed throughout the kitchen
area.
3. Make-up air registers located near the
hood, the louvers should be adjusted
to direct the air away from the hood.
Directing or forcing make-up air at the
hood typically creates cross drafts
resulting in smoke loss. Ceiling make-
up air should not exceed 150 FPM at
the inlet.
E.
Exhaust fan discharge.
1.
There should be no screen over the
discharge. If one is found, it should be
removed.
2. The direction of discharge should
not be into the prevailing winds nor
downward onto the roof. A vertical
discharge is highly recommended.
GREASE EXTRACTION
1.
Poor Grease Extraction
A.
Hoods with too much air being pulled
through them can have grease pull
through.
1.
To see if you are pulling the proper
amount of air through the system, see
Figure 21.
2. Wash XG Extractors more frequently.
3. Noise
B. Hoods pulling too much air through
the extractor can cause excessive
noise.
1.
Adjust motor / fan speed down to
eliminate excessive noise. After
doing so, verify the hood is properly
capturing all smoke.
2. Adjust GBD damper up or down as
needed to eliminate noise. Watch for
changes in other hood’s flow rates as
a result of damper manipulation.
Содержание XG-BDL
Страница 13: ...10 GFBD EXTERNAL WIRING MULTIPLE SECTION FIGURE 16B GFBD External Wiring Diagram ...
Страница 29: ...26 UV HOOD WIRING BOARD SCHEMATIC ...
Страница 30: ...27 WIRING DIAGRAM FOR MODEL CUV 100 WITH XG UV SERIES HOODS ...
Страница 31: ...28 WIRING DIAGRAM FOR GAD 100 CONTROLLERS WITH GFBD DAMPERS ...
Страница 32: ...29 WIRING DIAGRAM FOR GAD 100 CONTROLLERS WITH NO DAMPER ...