To install a new lamp:
DISCONNECT THE BALLAST FIRST
Make sure the lamp is clean, wear cotton gloves and clean the lamp after installation with a dry soft
cloth. Never use detergents to clean a lamp, use pure alcohol and/or wipe with a dry clean soft cloth.
Make sure the end wires are straight
Open the lamp holders by sliding them outward
Install the lamp with the getter (see illustration) at the side of the ballast, with the glass vacuum seal
pointed downward. Press the lamp in the fitting until the metal springs hold the lamp.
Close the lamp holders by sliding them inward
Wipe the lamp with a clean soft cloth
Be sure not to touch the reflective material of the reflector with your bare hands.
Getter
Seal
Open