Connecting multiple LED fixtures to a controller

  Warning!

  Mounting and installing of the E-series adapter(s) may only be executed by certified service personnel, in 

accordance with the applicable local laws and regulations.

  Warning!

  The installer is responsible for correct and safe installation.

  Warning!

  Ensure the local cabling can support the voltage and current requirements of the LED fixture and E-series adapter.

   Warning!

  Avoid coiled cords and keep mains leads separated. This prevents electromagnetic interference.

   Warning!

  Do not connect or disconnect the LED fixture under load. 

7.1 

Contents E-series adapter (fig. 8) 

*Not included, sold separately.

A. 

Wieland RST 16i5 male connector

B. 

Gavita 2xRJ connector

1. RJ IN

2. RJ OUT

7.2 

Contents of the repeater bus connection kit  

*Not included, sold separately.

The E-series adapter interconnect kit contains the following items: 

C. 

80ft interconnect cable

D. 

RJ45 + 3x RJ14 terminal connectors (3x)

OPTIONAL: 

• 

Interconnect cable, 3 way splitter

• 

Interconnect cable, crimper

• 

Crimp tool

7.3 

Preparation for use with a controller

Using a daisy chain setup, a maximum of 100 E-series adapters can be connected to one controller. Up to 500 E-series 

adapters per daisy chain can be connected when using splitters. See section 7.4 and 7.5 of this manual and the manual of the 

controller.

• 

Take the unstripped interconnect cable.

• 

Cut the cable to the desired length and strip both ends using a crimp tool (fig. 7).

• 

Insert the cable end in the RJ connectors (fig. 8) and use a crimp tool to finish the assembly.

B1

B2

A

6.   

7.   

8.   

Содержание Pro 1700 LED EU 240

Страница 1: ...roduct may not be discarded as household waste By properly disposing the equipment you will be helping to prevent possible risks to the environment and public health which might otherwise be caused by improper handling of the discarded equipment Recycling of materials contributes to the conservation of natural resources Therefore please do not dispose of old electronics and electrical appliances v...

Страница 2: ... 5 meter PC6852002 Gavita Power cord ESA CH 2 5 meter PC6852001 Gavita Power cord ESA AUS 2 5 meter PC6852005 Interconnect cables Gavita Interconnect cable ESA RJ45 RJ45 10 ft 3 0m HGC906711 Gavita Controller cable ESA RJ45 RJ9 25 ft 7 5m HGC906717 Gavita Controller cable ESA RJ45 RJ9 10 ft 3 0m HGC906716 Gavita 3 way splitter ESA 1f to 2f RJ45 HGC906721 Sun Grips Sun Grip Original Light Hanger 1 ...

Страница 3: ...atures outside the specified range dust and contamination direct sunlight during use or HID light that could heat up the ballast Always disconnect the LED fixture from mains before performing any maintenance Always allow for a cool down period of at least 30 minutes before touching the LED rails Touching the LED rails when the fixture is lit or immediately afterwards can result in severe burns Do ...

Страница 4: ...s B Distribute the fixture weight evenly so fixture hangs level fig 3 Sun Grip light hangers allow the LED fixture to easily move upwards and downwards fig 4 according to your crop height fig 5 Make sure power cords 1 Are not concealed or extended through a wall floor ceiling or other parts of the building structures 2 Are not located above a suspended ceiling or dropped ceiling 3 Are not permanen...

Страница 5: ...re If you use the LED fixture stand alone connect the Wieland RST 16i5 female connector on the power cable to the Wieland RST16i5 male connector on the LED fixture fig 13 If you use the LED fixture with a Master Controller connect the Wieland RST16i5 female connector on an E series adapter not included to the Wieland RST16i5 male connector on the LED fixture fig 14 Connect the power cable to the m...

Страница 6: ...i5 male connector B Gavita 2xRJ connector 1 RJ IN 2 RJ OUT 7 2 Contents of the repeater bus connection kit Not included sold separately The E series adapter interconnect kit contains the following items C 80ft interconnect cable D RJ45 3x RJ14 terminal connectors 3x OPTIONAL Interconnect cable 3 way splitter Interconnect cable crimper Crimp tool 7 3 Preparation for use with a controller Using a da...

Страница 7: ... to connect the controller input port on the first E series adapter fig 10A Remove the dummy from the input port on the second E series adapter Use interconnect cable RJ45 RJ45 to connect the output port of the first E series adapter to the input port of the second E series adapter fig 10B Repeat these steps to connect up to 100 E series adapters fig 10C Warning Ensure the power cord and the contr...

Страница 8: ...port of the second fig 12D Repeat these steps to connect up to 100 E series adapters per splitter output port fig 12E Up to 500 E series adapters can be connected to the primary channel Use RJ45 RJ45 modular jack interconnect cables item C to connect the outport of a splitter to the input port of the next splitter fig 12F Use the secondary channel fig 12G to connect another 500 E series adapters i...

Страница 9: ...i5 female connector counterclockwise and pull the Wieland RST16i5 female connection from the LED fixture fig 15 10 Storage and disposal Store the LED fixture in a dry and clean environment with an ambient temperature of 20 85 C The product must not be discarded as unsorted municipal waste but must be collected separately for the purpose of treatment recovery and environmentally sound disposal 11 W...

Страница 10: ...e LED EU Changes reserved Version 20 18 Not for sale or use in the Netherlands GAVITA International bv Oosteinderweg 127 1432 AH Aalsmeer The Netherlands Tel 31 0 297 380 450 Fax 31 0 297 380 451 E info gavita com W www gavita com ...

Отзывы: